SKShatrughna Kumar

Shatrughna Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shatrughna Kumar has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enhancing Bimetallic SPR Sensor’s Performance: The Role of 2D and TMDC Nanomaterials

    by Archana Yadav, Shatrughna Kumar, Boris A. Malomed


  • Open Access

    Stable Patterns in the Lugiato-Lefever Equation with a Confined Vortex Pump

    by Shatrughna Kumar, Wesley Cardoso, Boris Malomed

    We introduce a model of a passive optical cavity based on the two-dimensional Lugiato-Lefever equation, with a localized pump carrying intrinsic vorticity S, and the cubic or cubic-quintic nonlinearity. Up to S = 5, stable vortex-ring states (vortex pixels) are produced by a variational approximation and in a numerical form. Surprisingly, vast stability areas of the vortex states are found, for both the self-focusing and defocusing signs of the nonlinearity, in the plane of the pump-strength and loss parameters. When the vortex-rings are unstable, they are destroyed by azimuthal perturbations which break the axial symmetry. The results suggest new possibilities for mode manipulations in nonlinear optical media.

  • Open Access

    Corrigendum: Effect of 2-D nanomaterials on sensitivity of plasmonic biosensor for efficient urine glucose detection

    by Archana Yadav, Shatrughna Kumar, Anil Kumar, Preeta Sharan

    Corrigendum: Effect of 2-D nanomaterials on sensitivity of plasmonic biosensor for efficient urine glucose detection

  • Open Access

    Corrigendum: High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer

    by Shatrughna Kumar, Archana Yadav, Boris A. Malomed

    Corrigendum: High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer


  • Open Access

    High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer

    by Shatrughna Kumar, Archana Yadav, Boris A. Malomed

    A five-layered Kretschmann configuration-based novel structure is designed for a highly sensitive surface plasmon resonance (SPR) sensor. An adhesion layer of magnesium oxide (MgO) is employed on the BK7 prism to avoid the adverse effects of metallic layers, which cause SPR broadening and a decrease in the resonance magnitude. A few layers of black phosphorus (BP) on top of the silver (Ag) metal layer are added to complete the structure, which becomes the BK7/MgO/Ag/BP configuration. The investigation is carried out using attenuated total reflection (ATR), while the widely used transfer matrix method (TMM) is applied to evaluate the performance of the SPR sensor. A separate analysis is performed using three thicknesses, 5 nm, 10 nm, and 15 nm of MgO, an optimized thickness of 40 nm of Ag, and eight layers of BP. The results revealed that the configuration BK7/MgO (10 nm)/Ag (40 nm)/BP (8 layers) delivers a maximum sensitivity (S) of 234°RIU−1. Moreover, the configuration BK7/MgO (5 nm)/Ag (40 nm)/BP (8 layers) delivers a maximum figure of merit (FOM) of 38.18°RIU−1. With these kinds of extraordinary features, it is expected that the proposed SPR sensor can be applied in different fields of biosensing.


  • Open Access

    Effect of 2-D nanomaterials on sensitivity of plasmonic biosensor for efficient urine glucose detection

    by Archana Yadav, Shatrughna Kumar, Anil Kumar, Preeta Sharan

    This paper presents a multi-layered Kretschmann configuration-based Surface Plasmon Resonance (SPR) biosensor for the detection of urine glucose. The modelling, simulation, and analysis have been done by using Silver (Ag) and Gold (Au) layer on the low refractive index prism BK-7 separately, which created two structures: structure-I (BK7/Ag/Bio-sample) and structure-II (BK7/Au/Bio-sample). Urine samples from a non-diabetic person (0–15 mg/dL) and a diabetic person (.625 gm/dL, 1.25 gm/dL, 2.5 gm/dL, 5 gm/dL, and 10 gm/dL) with the corresponding refractive indices of 1.335, 1.336, 1.337, 1.338, 1.341, and 1.347, respectively, have been used as a bio-sample that has been put on the top layer of the sensor. An investigation was conducted to improve the performance parameters of the proposed plasmonic biosensor by layering different 2-D nanomaterials (graphene, BP) and TMDC materials (MoS2, MoSe2, WS2, and WSe2) over the silicon (Si) layer in both structures at a visible wavelength of 633 nm, using Transfer Matrix Method (TMM). With layer thickness optimization, Structure-I (BK7/Ag (56 nm/Si (3 nm)/WS2 (.8 nm)/Bio-sample) shows a sensitivity of 200 °/RIU which is enhanced up to 1.7 times that of the conventional biosensor (BK7/Ag/Bio-sample) and 1.3 times that of the BK7/Ag (56 nm)/Si (3 nm)/Bio-sample based biosensor. Whereas in Structure-II (BK7/Au (50 nm)/Si (3 nm)/BP (.53 nm)/Bio-sample) with optimised layer thickness, we obtained a sensitivity of 273.4°/RIU, which is enhanced up to 2.2 times that of the conventional biosensor (BK7/Au/Bio-sample) and 1.3 times that of the BK7/Au (50 nm)/Si (3 nm)/Bio-sample. Other performance parameters such as detection accuracy for Structure-I and Structure-II are .5617 degree−1 and .134 degree−1 respectively. The Figure of merit for Structure-I and Structure-II are 112.35/RIU and 36.89/RIU respectively. Therefore, we expect Structure-I (BK7/Ag (56 nm/Si (3 nm)/WS2 (.8 nm)/Bio-sample) and Structure-II (BK7/Au (50 nm)/Si (3 nm)/BP (.53 nm)/Bio-sample) have the potential to detect the glucose concentration with quick response and high sensitivity in terms of the resonance angle shift in SPR curves.


  • Open Access

    Domain walls in fractional media

    by Shatrughna Kumar, Pengfei Li, Boris A. Malomed

    Currently, much interest is drawn to the analysis of optical and matter-wave modes supported by the fractional diffraction in nonlinear media. We predict a new type of such states in the form of domain walls (DWs) in the two-component system of immiscible fields. Numerical study of the underlying system of fractional nonlinear Schrödinger equations demonstrates the existence and stability of DWs at all values of the respective Lévy index (α<2), which determines the fractional diffraction, and at all values of the XPM/SPM ratio β in the two-component system above the immiscibility threshold. The same conclusion is obtained for DWs in the system which includes the linear coupling, alongside the XPM interaction between the immiscible components. Analytical results are produced for the scaling of the DW's width. The DW solutions are essentially simplified in the special case of β=3, as well as close to the immiscibility threshold. In addition to symmetric DWs, asymmetric ones are constructed too, in the system with unequal diffraction coefficients and/or different Lévy indices of the two components.


  • Low-power, high-performance, and small-footprint, single-pump optical parametric amplifier for photonic integrated circuits

    by Shatrughna Kumar, Mrinal Sen

    A single-pump optical parametric amplifier (OPA) is modeled using a p-toluene sulfonate (PTS) filled silicon-based slotted photonic crystal waveguide (SPCW). The PTS-SPCW has CMOS-process compatibility and offers slow-light enhanced nonlinearity of PTS due to extreme optical confinement in SPCW. The adverse effects of two-photon absorption and free carrier absorption are absent in PTS in the standard optical communication window. The coupled nonlinear Schrödinger’s equations have been modified to analyze the OPA under slow-light propagation. Performances of the OPA are evaluated in both the high- and low- dispersive zones of the structure. The high dispersive zone exhibits high group indices to the operating waves, leading to a high parametric gain (≈31 dB) and high conversion efficiency (≈27 dB) utilizing a 350 μm long PTS-SPCW and a pump power of 65 mW. However, this zone degrades the shape of a ≤10 ps pulse due to self-phase and cross-phase modulation. On the other hand, in the low dispersive zone, a similar parametric gain and conversion efficiency (both ≈29 dB) are attained utilizing a 1250 μm long PTS-SPCW and a pump power of 150 mW. Nevertheless, this zone degrades a 5 ps pulse only after a distance of 1500 μm . The analyses show a 30 nm bandwidth considering a gain above 30 dB. Investigation of the effect of fabrication imperfections shows excellent performance sustainability of the OPA up to a random error of 40 nm. These remarkable performances make this low-powered, small-footprint OPA suitable for achieving tunable optical amplification in photonic integrated circuits.


  • Integrable all-optical switch for photonic integrated circuits

    by Shatrughna Kumar, Mrinal Sen

    A completely new model of an all-optical switch (AOS) is proposed using a silicon photonic crystal (PhC) slab based nonlinear Mach–Zehnder interferometer (NMZI). Both arms of the NMZI are designed using p-toluene sulfonate (PTS) based slotted PhC waveguides (PTS-SPCWs). Extreme optical confinement in SPCW is used here to intensify optical nonlinearities of PTS. The intensified nonlinearity produces significant phase changes in optical pulses within a small waveguide length, even when the optical power is sufficiently small. One arm of the NMZI is coupled with a control wave to incur additional phase shift compared to the other due to cross-phase modulation, in addition to self-phase modulation, which is a common phenomenon for both. The differential phase shift originates destructive/constructive interference, leading to a successful switching operation of the AOS. Switching characteristics of the AOS are evaluated for a variety of parameters. A typical example shows that the AOS can switch off 12.55 mW probe power with an extinction ratio of ≈ 50.5 d B by applying 5.65 mW control power, while the device footprint is merely 259 µ m 2 . The low-power and high-speed operation makes this small footprint AOS device suitable for applications in photonic integrated circuits.