Archana Yadav
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Archana Yadav has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Boris A. Malomed
Centre for Light-Matter Interaction, Tel Aviv University
5 shared publications- Shatrughna Kumar
Department of Physical Electronics, School of Electrical Engineering, Faculty of Engineering, and Center for Light-Matter Interaction, Tel Aviv University, Tel Aviv, Israel
5 shared publications - Anil Kumar
Amity School of Engineering and Technology, Amity University, Lucknow Campus, Lucknow, Uttar Pradesh, India
4 shared publications Preeta Sharan
Department of ECE, The Oxford College of Engineering, Bangaluru, India
4 shared publications- Preeta Sharan
Department of Electronics and Communication Engineering The Oxford College of Engineering, Affiliated to Visvesvaraya Technological University Bengaluru Karnataka India
3 shared publications Shatrughna Kumar
Centre for Light-Matter Interaction, Tel Aviv University
3 shared publications
Latest Publications
- 30 October 2025
- Published by Springer Nature
- p. 43-67
Noble-Metal-Based Composites for High-Performance SPR Sensors
- 30 October 2025
- Published by Springer Nature
- p. 43-67
Noble-Metal-Based Composites for High-Performance SPR Sensors
- 4 August 2025
- Published by Springer Nature in Plasmonics
- Vol. 20 (8) , 6303-6312
Design and Analysis of SrTiO₃-Enhanced SPR Biosensor for Improved Sensitivity in Non-invasive Glucose Sensing
- 4 August 2025
- Published by Springer Nature in Plasmonics
- Vol. 20 (8) , 6303-6312
Design and Analysis of SrTiO₃-Enhanced SPR Biosensor for Improved Sensitivity in Non-invasive Glucose Sensing
- 2 August 2025
- Published by Springer Nature in Plasmonics
- Vol. 20 (12) , 11713-11727
Highly Sensitive Plasmonic Sensors Based on Silicon and Nitrides of Si and Ga on Mono and Bimetallic Layers for Biomedical Applications
- 2 August 2025
- Published by Springer Nature in Plasmonics
- Vol. 20 (12) , 11713-11727
Highly Sensitive Plasmonic Sensors Based on Silicon and Nitrides of Si and Ga on Mono and Bimetallic Layers for Biomedical Applications
- 27 September 2024
- Published by Springer Nature in Journal of Optics
- Vol. 55 (2) , 1368-1376
A Review Of Surface Plasmon Resonance (SPR) Technology In Biosensing: Innovations, Applications And Future Trends
- 27 September 2024
- Published by Springer Nature in Journal of Optics
- Vol. 55 (2) , 1368-1376
A Review Of Surface Plasmon Resonance (SPR) Technology In Biosensing: Innovations, Applications And Future Trends
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 7671-7680
Design and Simulation of SPR Sensors by Employing Silicon and Silicon-Nitride With Mono and Bimetal Layers for Sensitivity Enhancement
In this work, three novel Surface Plasmon Resonance (SPR) sensors based on the Kretschmann configuration are proposed. The optimized structural designs of Sensor-1 [BK7/Si(42nm)/Au(25nm)/Ag(25nm)/Si3N4 (18nm)/Sensing medium] and Sensor-2 [BK7/Si(10nm)/Au(30nm)/Ag(30nm)/Si3N4(20nm)/Sensing medium] incorporate bimetallic layers of Gold (Au) and Silver (Ag), while Sensor-3 [BK7/Si(32nm)/Ag(25nm)/Si3N4(20nm)/Sensing medium] includes only an Ag layer. These biosensors feature Silicon (Si) and Silicon Nitride (Si3N4) as dielectric layers. The study employs the transfer matrix method to optimize the sensors and evaluates their performance using the angle modulation method. Results indicate that reverse optimization, optimizing the Si3N4 layer before the Si layer, yields significantly better performance than conventional optimization. Sensor-2 outperforms Sensor-1 and Sensor-3, demonstrating superior sensitivity, detection accuracy, and figure of merit. The maximum sensitivity (S), Detection accuracy (DA), and figure of merit (FoM) for Sensor-1 are calculated as 440°/ RIU, 0.1470 1/degree, and 64.70 1/RIU, respectively. Sensor-2 and Sensor-3 achieve even higher performance when analyzed using reverse optimization, with their sensitivity (S), Detection accuracy (DA), and figure of merit (FoM) values at 460°/RIU, 0.2222 1/degree, 102.222 1/RIU, and 460°/RIU, 0.2197 1/degree, 101.09 1/RIU, respectively. These novel SPR sensors demonstrate exceptional performance, as substantiated by a thorough comparison with recently published works in the field of biomedical applications. This comparison underscores the sensors’ considerable potential in biosensing and biomedicine.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 7671-7680
Design and Simulation of SPR Sensors by Employing Silicon and Silicon-Nitride With Mono and Bimetal Layers for Sensitivity Enhancement
In this work, three novel Surface Plasmon Resonance (SPR) sensors based on the Kretschmann configuration are proposed. The optimized structural designs of Sensor-1 [BK7/Si(42nm)/Au(25nm)/Ag(25nm)/Si3N4 (18nm)/Sensing medium] and Sensor-2 [BK7/Si(10nm)/Au(30nm)/Ag(30nm)/Si3N4(20nm)/Sensing medium] incorporate bimetallic layers of Gold (Au) and Silver (Ag), while Sensor-3 [BK7/Si(32nm)/Ag(25nm)/Si3N4(20nm)/Sensing medium] includes only an Ag layer. These biosensors feature Silicon (Si) and Silicon Nitride (Si3N4) as dielectric layers. The study employs the transfer matrix method to optimize the sensors and evaluates their performance using the angle modulation method. Results indicate that reverse optimization, optimizing the Si3N4 layer before the Si layer, yields significantly better performance than conventional optimization. Sensor-2 outperforms Sensor-1 and Sensor-3, demonstrating superior sensitivity, detection accuracy, and figure of merit. The maximum sensitivity (S), Detection accuracy (DA), and figure of merit (FoM) for Sensor-1 are calculated as 440°/ RIU, 0.1470 1/degree, and 64.70 1/RIU, respectively. Sensor-2 and Sensor-3 achieve even higher performance when analyzed using reverse optimization, with their sensitivity (S), Detection accuracy (DA), and figure of merit (FoM) values at 460°/RIU, 0.2222 1/degree, 102.222 1/RIU, and 460°/RIU, 0.2197 1/degree, 101.09 1/RIU, respectively. These novel SPR sensors demonstrate exceptional performance, as substantiated by a thorough comparison with recently published works in the field of biomedical applications. This comparison underscores the sensors’ considerable potential in biosensing and biomedicine.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 23 (2) , 336-343
Bimetal Thin Film, Semiconductors, and 2D Nanomaterials in SPR Biosensors: An Approach to Enhanced Urine Glucose Sensing
This work introduces a systematic approach for the development of Kretschmann configuration-based biosensors designed for non-invasive urine glucose detection. The methodology encompasses the utilization of various semiconductors, including Silicon (Si), Germanium (Ge), Gallium Nitride (GaN), Aluminum Nitride (AlN), and Indium Nitride (InN), in combination with a bimetallic layer (comprising Au and Ag films of equal thickness) to enhance the biosensor sensitivity. Additionally, 2D nanomaterials, such as Black Phosphorus and Graphene, are integrated into the semiconductor layers to enhance performance further. These configurations are meticulously optimized through the application of the transfer matrix method (TMM), and the sensing parameters are assessed using the angular modulation method. Among the semiconductors, AlN and GaN exhibit superior results. On these substrates, Graphene and Black phosphorous (BP) layers are applied, resulting in four final structures (thicknesses in nm): BK7/Au(26)/Ag(26)/Si(6)/BP(0.53)/Biosample, BK7/Au(26)/Ag(26)/AlN(14)/BP(0.53)/Biosample, BK7/Au(26)/Ag(26)/GaN(12)/BP(0.53)/Biosample, and BK7/Au(26)/Ag(26)/GaN(12)/Graphene(0.34)/Biosample. These biosensors achieve Sensitivity(° /RIU) and Figure of Merit (FoM) (1/RIU) of 380, 360, 440, 400, and 58.5, 90, 90.65, and 82.4, respectively. Subsequently, these high-performing sensors undergo testing with actual urine glucose samples. Among them, two biosensors, BK7/Au(26)/Ag(26)/AlN(14)/BP (0.53)/Biosample and BK7/Au(26)/Ag(26)/GaN(14)/Graphene(0.34)/Biosample, exhibit outstanding performance, with sensitivities (° /RIU) and FoM (1/RIU) of 394.44 & 294.44, and 112.6 & 92.01 respectively. A comparison is also made with relevant previously published work, revealing improved performance in glucose detection.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 23 (2) , 336-343
Bimetal Thin Film, Semiconductors, and 2D Nanomaterials in SPR Biosensors: An Approach to Enhanced Urine Glucose Sensing
This work introduces a systematic approach for the development of Kretschmann configuration-based biosensors designed for non-invasive urine glucose detection. The methodology encompasses the utilization of various semiconductors, including Silicon (Si), Germanium (Ge), Gallium Nitride (GaN), Aluminum Nitride (AlN), and Indium Nitride (InN), in combination with a bimetallic layer (comprising Au and Ag films of equal thickness) to enhance the biosensor sensitivity. Additionally, 2D nanomaterials, such as Black Phosphorus and Graphene, are integrated into the semiconductor layers to enhance performance further. These configurations are meticulously optimized through the application of the transfer matrix method (TMM), and the sensing parameters are assessed using the angular modulation method. Among the semiconductors, AlN and GaN exhibit superior results. On these substrates, Graphene and Black phosphorous (BP) layers are applied, resulting in four final structures (thicknesses in nm): BK7/Au(26)/Ag(26)/Si(6)/BP(0.53)/Biosample, BK7/Au(26)/Ag(26)/AlN(14)/BP(0.53)/Biosample, BK7/Au(26)/Ag(26)/GaN(12)/BP(0.53)/Biosample, and BK7/Au(26)/Ag(26)/GaN(12)/Graphene(0.34)/Biosample. These biosensors achieve Sensitivity(° /RIU) and Figure of Merit (FoM) (1/RIU) of 380, 360, 440, 400, and 58.5, 90, 90.65, and 82.4, respectively. Subsequently, these high-performing sensors undergo testing with actual urine glucose samples. Among them, two biosensors, BK7/Au(26)/Ag(26)/AlN(14)/BP (0.53)/Biosample and BK7/Au(26)/Ag(26)/GaN(14)/Graphene(0.34)/Biosample, exhibit outstanding performance, with sensitivities (° /RIU) and FoM (1/RIU) of 394.44 & 294.44, and 112.6 & 92.01 respectively. A comparison is also made with relevant previously published work, revealing improved performance in glucose detection.
- Open Access
- 14 November 2023
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 10, 1333014
Corrigendum: Effect of 2-D nanomaterials on sensitivity of plasmonic biosensor for efficient urine glucose detection
Corrigendum: Effect of 2-D nanomaterials on sensitivity of plasmonic biosensor for efficient urine glucose detection
- 14 November 2023
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 10, 1333014
Open AccessCorrigendum: Effect of 2-D nanomaterials on sensitivity of plasmonic biosensor for efficient urine glucose detection
Corrigendum: Effect of 2-D nanomaterials on sensitivity of plasmonic biosensor for efficient urine glucose detection
- Open Access
- 1 November 2023
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 10, 1290821
Corrigendum: High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer
Corrigendum: High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer
- 1 November 2023
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 10, 1290821
Open AccessCorrigendum: High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer
Corrigendum: High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer
- Open Access
- 1 March 2023
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 10
High performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer
A five-layered Kretschmann configuration-based novel structure is designed for a highly sensitive surface plasmon resonance (SPR) sensor. An adhesion layer of magnesium oxide (MgO) is employed on the BK7 prism to avoid the adverse effects of metallic layers, which cause SPR broadening and a decrease in the resonance magnitude. A few layers of black phosphorus (BP) on top of the silver (Ag) metal layer are added to complete the structure, which becomes the BK7/MgO/Ag/BP configuration. The investigation is carried out using attenuated total reflection (ATR), while the widely used transfer matrix method (TMM) is applied to evaluate the performance of the SPR sensor. A separate analysis is performed using three thicknesses, 5 nm, 10 nm, and 15 nm of MgO, an optimized thickness of 40 nm of Ag, and eight layers of BP. The results revealed that the configuration BK7/MgO (10 nm)/Ag (40 nm)/BP (8 layers) delivers a maximum sensitivity (S) of 234°RIU−1. Moreover, the configuration BK7/MgO (5 nm)/Ag (40 nm)/BP (8 layers) delivers a maximum figure of merit (FOM) of 38.18°RIU−1. With these kinds of extraordinary features, it is expected that the proposed SPR sensor can be applied in different fields of biosensing.
- 1 March 2023
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 10
Open AccessHigh performance surface plasmon resonance based sensor using black phosphorus and magnesium oxide adhesion layer
A five-layered Kretschmann configuration-based novel structure is designed for a highly sensitive surface plasmon resonance (SPR) sensor. An adhesion layer of magnesium oxide (MgO) is employed on the BK7 prism to avoid the adverse effects of metallic layers, which cause SPR broadening and a decrease in the resonance magnitude. A few layers of black phosphorus (BP) on top of the silver (Ag) metal layer are added to complete the structure, which becomes the BK7/MgO/Ag/BP configuration. The investigation is carried out using attenuated total reflection (ATR), while the widely used transfer matrix method (TMM) is applied to evaluate the performance of the SPR sensor. A separate analysis is performed using three thicknesses, 5 nm, 10 nm, and 15 nm of MgO, an optimized thickness of 40 nm of Ag, and eight layers of BP. The results revealed that the configuration BK7/MgO (10 nm)/Ag (40 nm)/BP (8 layers) delivers a maximum sensitivity (S) of 234°RIU−1. Moreover, the configuration BK7/MgO (5 nm)/Ag (40 nm)/BP (8 layers) delivers a maximum figure of merit (FOM) of 38.18°RIU−1. With these kinds of extraordinary features, it is expected that the proposed SPR sensor can be applied in different fields of biosensing.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 22 (4) , 897-903
Highly Sensitive Bimetallic-Metal Nitride SPR Biosensor for Urine Glucose Detection
The present study introduces a highly sensitive bimetallic SPR biosensor based on metal nitride for efficient urine glucose detection. Using a BK-7 prism, Au (25 nm), Ag (25nm), AlN (15 nm), and a biosample (urine) layer, the proposed sensor comprises of five layers. The selection of the sequence and dimensions of both metal layers is based on their performance in a number of case studies including both monometallic and bimetallic layers. After optimizing the bimetallic layer as Au (25 nm) – Ag (25 nm), various nitride layers were used to further increase the sensitivity by utilizing the synergistic effect of the bimetallic and metal nitride layers through case studies of several urine samples, ranging from nondiabetic to severely diabetic patients. AlN is determined to be the best suited material, and its thickness is optimized to 15 nanometers. The performance of the structure has been evaluated using a visible wavelength, i.e., λ = 633 nm, in order to increase sensitivity while providing room for low-cost prototyping. With the layer parameters optimized, a significant sensitivity of 411°/RIU (Refractive Index Unit) and figure of merit (FoM) of 105.38 /RIU has been achieved. The computed resolution of the proposed sensor is 4.17e-06. This study’s findings have also been compared to some recently reported results. The proposed structure would be useful for detecting glucose concentrations, with a rapid response as measured by a substantial shift in resonance angle in SPR curves.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 22 (4) , 897-903
Highly Sensitive Bimetallic-Metal Nitride SPR Biosensor for Urine Glucose Detection
The present study introduces a highly sensitive bimetallic SPR biosensor based on metal nitride for efficient urine glucose detection. Using a BK-7 prism, Au (25 nm), Ag (25nm), AlN (15 nm), and a biosample (urine) layer, the proposed sensor comprises of five layers. The selection of the sequence and dimensions of both metal layers is based on their performance in a number of case studies including both monometallic and bimetallic layers. After optimizing the bimetallic layer as Au (25 nm) – Ag (25 nm), various nitride layers were used to further increase the sensitivity by utilizing the synergistic effect of the bimetallic and metal nitride layers through case studies of several urine samples, ranging from nondiabetic to severely diabetic patients. AlN is determined to be the best suited material, and its thickness is optimized to 15 nanometers. The performance of the structure has been evaluated using a visible wavelength, i.e., λ = 633 nm, in order to increase sensitivity while providing room for low-cost prototyping. With the layer parameters optimized, a significant sensitivity of 411°/RIU (Refractive Index Unit) and figure of merit (FoM) of 105.38 /RIU has been achieved. The computed resolution of the proposed sensor is 4.17e-06. This study’s findings have also been compared to some recently reported results. The proposed structure would be useful for detecting glucose concentrations, with a rapid response as measured by a substantial shift in resonance angle in SPR curves.