John Thomas Vaughan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John Thomas Vaughan has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Sairam Geethanath
Columbia University Magnetic Resonance Research Center, Columbia University in the City of New York, New York, NY, United States
3 shared publications - Keerthi Sravan Ravi
Department of Biomedical Engineering Columbia University in the City of New York New York New York USA
2 shared publications - Marina Manso Jimeno
Department of Biomedical Engineering Columbia University in the City of New York New York New York USA
2 shared publications - Barbara J. Evans
Fredric Levin College of Law and Herbert Wertheim College of Engineering, University of Florida, Gainesville
1 shared publication - Damien A. Fair
Masonic Institute for the Developing Brain, University of Minnesota, Minneapolis, MN, USA
1 shared publication - David H. Gultekin
Rockefeller Neuroscience Institute, Department of Neuroradiology, School of Medicine, West Virginia University, Morgantown, WV 26506, USA
1 shared publication
Latest Publications
- Open Access
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (2) , 491-492
Reply to “Comments on ‘Experimental Evaluation of Relationship Between Radiofrequency Heating Near Implanted Conductive Devices, Scanner-Reported B 1+rms , and Transmit Power’”
We describe the relationship between the RF-induced temperature change in a conductive metallic implant during the MRI, B1+rms, and RF power for RF pulse sequences, RF coils, and Tx/Rx combinations. We show that both temperature and RF power change with RF pulse sequences, RF coils, and Tx/Rx combinations, whereas B1+rms changes only with RF pulse sequences but not RF coils and Tx/Rx combinations. As a result, induced heating is associated with RF power propagation and loss corresponding to the B1+rms.
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (2) , 491-492
Open AccessReply to “Comments on ‘Experimental Evaluation of Relationship Between Radiofrequency Heating Near Implanted Conductive Devices, Scanner-Reported B 1+rms , and Transmit Power’”
We describe the relationship between the RF-induced temperature change in a conductive metallic implant during the MRI, B1+rms, and RF power for RF pulse sequences, RF coils, and Tx/Rx combinations. We show that both temperature and RF power change with RF pulse sequences, RF coils, and Tx/Rx combinations, whereas B1+rms changes only with RF pulse sequences but not RF coils and Tx/Rx combinations. As a result, induced heating is associated with RF power propagation and loss corresponding to the B1+rms.
- Open Access
- 1 January 2024
- Published by Oxford University Press (OUP) in Journal of Law and the Biosciences
- Vol. 11 (1) , lsae008
Ethical, legal, and policy challenges in field-based neuroimaging research using emerging portable MRI technologies: guidance for investigators and for oversight
Researchers are rapidly developing and deploying highly portable MRI technology to conduct field-based research. The new technology will widen access to include new investigators in remote and unconventional settings and will facilitate greater inclusion of rural, economically disadvantaged, and historically underrepresented populations. To address the ethical, legal, and societal issues raised by highly accessible and portable MRI, an interdisciplinary Working Group (WG) engaged in a multi-year structured process of analysis and consensus building, informed by empirical research on the perspectives of experts and the general public. This article presents the WG’s consensus recommendations. These recommendations address technology quality control, design and oversight of research, including safety of research participants and others in the scanning environment, engagement of diverse participants, therapeutic misconception, use of artificial intelligence algorithms to acquire and analyze MRI data, data privacy and security, return of results and managing incidental findings, and research participant data access and control.
- 1 January 2024
- Published by Oxford University Press (OUP) in Journal of Law and the Biosciences
- Vol. 11 (1) , lsae008
Open AccessEthical, legal, and policy challenges in field-based neuroimaging research using emerging portable MRI technologies: guidance for investigators and for oversight
Researchers are rapidly developing and deploying highly portable MRI technology to conduct field-based research. The new technology will widen access to include new investigators in remote and unconventional settings and will facilitate greater inclusion of rural, economically disadvantaged, and historically underrepresented populations. To address the ethical, legal, and societal issues raised by highly accessible and portable MRI, an interdisciplinary Working Group (WG) engaged in a multi-year structured process of analysis and consensus building, informed by empirical research on the perspectives of experts and the general public. This article presents the WG’s consensus recommendations. These recommendations address technology quality control, design and oversight of research, including safety of research participants and others in the scanning environment, engagement of diverse participants, therapeutic misconception, use of artificial intelligence algorithms to acquire and analyze MRI data, data privacy and security, return of results and managing incidental findings, and research participant data access and control.
- Open Access
- 4 March 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (59) , 2578
Off-resonance CorrecTion OPen soUrce Software (OCTOPUS)
- 4 March 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (59) , 2578
Open AccessOff-resonance CorrecTion OPen soUrce Software (OCTOPUS)
- Open Access
- 25 November 2019
- Published by The Open Journal in Journal of Open Source Software
- Vol. 4 (43) , 1637
Virtual Scanner: MRI on a Browser
- 25 November 2019
- Published by The Open Journal in Journal of Open Source Software
- Vol. 4 (43) , 1637
Open AccessVirtual Scanner: MRI on a Browser
- Open Access
- 12 October 2019
- Published by The Open Journal in Journal of Open Source Software
- Vol. 4 (42) , 1725
PyPulseq: A Python Package for MRI Pulse Sequence Design
Magnetic Resonance Imaging (MRI) is a critical component of healthcare. MRI data is acquired by playing a series of radio-frequency and magnetic field gradient pulses. Designing these pulse sequences requires knowledge of specific programming environments depending on the vendor hardware (generations) and software (revisions) intended for implementation. This impedes the pace of prototyping. Pulseq (Layton et al., 2017) introduced an open source file standard for pulse sequences that can be deployed on Siemens/GE via TOPPE (Nielsen & Noll, 2018)/Bruker platforms. In this work, we introduce PyPulseq, which enables pulse sequence programming in Python. Its advantages are zero licensing fees and easy integration with deep learning methods developed in Python. PyPulseq is aimed at MRI researchers, faculty, students, and other allied field researchers such as those in neuroscience. We have leveraged this tool for several published research works (Poojar, Geethanath, Reddy, & Venkatesan, n.d.;
- 12 October 2019
- Published by The Open Journal in Journal of Open Source Software
- Vol. 4 (42) , 1725
Open AccessPyPulseq: A Python Package for MRI Pulse Sequence Design
Magnetic Resonance Imaging (MRI) is a critical component of healthcare. MRI data is acquired by playing a series of radio-frequency and magnetic field gradient pulses. Designing these pulse sequences requires knowledge of specific programming environments depending on the vendor hardware (generations) and software (revisions) intended for implementation. This impedes the pace of prototyping. Pulseq (Layton et al., 2017) introduced an open source file standard for pulse sequences that can be deployed on Siemens/GE via TOPPE (Nielsen & Noll, 2018)/Bruker platforms. In this work, we introduce PyPulseq, which enables pulse sequence programming in Python. Its advantages are zero licensing fees and easy integration with deep learning methods developed in Python. PyPulseq is aimed at MRI researchers, faculty, students, and other allied field researchers such as those in neuroscience. We have leveraged this tool for several published research works (Poojar, Geethanath, Reddy, & Venkatesan, n.d.;