JKJames F. Klausner

James F. Klausner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James F. Klausner has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of tangential-type boundary condition discontinuities on the accuracy of the lattice Boltzmann method for heat and mass transfer

    by Like Li, Nick AuYeung, Renwei Mei, James F. Klausner

    We present a systematic study on the effects of tangential-type boundary condition discontinuities on the accuracy of the lattice Boltzmann equation (LBE) method for Dirichlet and Neumann problems in heat and mass transfer modeling. The second-order accurate boundary condition treatments for continuous Dirichlet and Neumann problems are directly implemented for the corresponding discontinuous boundary conditions. Results from three numerical tests, including both straight and curved boundaries, are presented to show the accuracy and order of convergence of the LBE computations. Detailed error assessments are conducted for the interior temperature or concentration (denoted as a scalar ϕ) and the interior derivatives of ϕ for both types of boundary conditions, for the boundary flux in the Dirichlet problem and for the boundary ϕ values in the Neumann problem. When the discontinuity point on the straight boundary is placed at the center of the unit lattice in the Dirichlet problem, it yields only first-order accuracy for the interior distribution of ϕ, first-order accuracy for the boundary flux, and zeroth-order accuracy for the interior derivatives compared with the second-order accuracy of all quantities of interest for continuous boundary conditions. On the lattice scale, the LBE solution for the interior derivatives near the singularity is largely independent of the resolution and correspondingly the local distribution of the absolute errors is almost invariant with the changing resolution. For Neumann problems, when the discontinuity is placed at the lattice center, second-order accuracy is preserved for the interior distribution of ϕ; and a “superlinear” convergence order of 1.5 for the boundary ϕ values and first-order accuracy for the interior derivatives are obtained. For straight boundaries with the discontinuity point arbitrarily placed within the lattice and curved boundaries, the boundary flux becomes zeroth-order accurate for Dirichlet problems; and all three quantities, including the interior and boundary ϕ values and the interior derivatives, are only first-order accurate for Neumann problems.


  • Top Cited Papers

    Conjugate heat and mass transfer in the lattice Boltzmann equation method

    by Like Li, Chen Chen, Renwei Mei, James F. Klausner

    An interface treatment for conjugate heat and mass transfer in the lattice Boltzmann equation method is proposed based on our previously proposed second-order accurate Dirichlet and Neumann boundary schemes. The continuity of temperature (concentration) and its flux at the interface for heat (mass) transfer is intrinsically satisfied without iterative computations, and the interfacial temperature (concentration) and their fluxes are conveniently obtained from the microscopic distribution functions without finite-difference calculations. The present treatment takes into account the local geometry of the interface so that it can be directly applied to curved interface problems such as conjugate heat and mass transfer in porous media. For straight interfaces or curved interfaces with no tangential gradient, the coupling between the interfacial fluxes along the discrete lattice velocity directions is eliminated and thus the proposed interface schemes can be greatly simplified. Several numerical tests are conducted to verify the applicability and accuracy of the proposed conjugate interface treatment, including (i) steady convection-diffusion in a channel containing two different fluids, (ii) unsteady convection-diffusion in the channel, (iii) steady heat conduction inside a circular domain with two different solid materials, and (iv) unsteady mass transfer from a spherical droplet in an extensional creeping flow. The accuracy and order of convergence of the simulated interior temperature (concentration) field, the interfacial temperature (concentration), and heat (mass) flux are examined in detail and compared with those obtained from the ``half-lattice division'' treatment in the literature. The present analysis and numerical results show that the half-lattice division scheme is second-order accurate only when the interface is fixed at the center of the lattice links, while the present treatment preserves second-order accuracy for arbitrary link fractions. For curved interfaces, the present treatment yields second-order accurate interior and interfacial temperatures (concentrations) and first-order accurate interfacial heat (mass) flux. An increase of order of convergence by one degree is obtained for each of these three quantities compared with the half-lattice division scheme. The surface-averaged Sherwood numbers computed in test (iv) agree well with published results.


  • Heat Transfer Evaluation on Curved Boundaries in Thermal Lattice Boltzmann Equation Method

    by Like Li, Renwei Mei, James F. Klausner

    An efficient and accurate approach for heat transfer evaluation on curved boundaries is proposed in the thermal lattice Boltzmann equation (TLBE) method. The boundary heat fluxes in the discrete velocity directions of the TLBE model are obtained using the given thermal boundary condition and the temperature distribution functions at the lattice nodes close to the boundary. Integration of the discrete boundary heat fluxes with effective surface areas gives the heat flow rate across the boundary. For lattice models with square or cubic structures and uniform lattice spacing the effective surface area is constant for each discrete heat flux, thus the heat flux integration becomes a summation of all the discrete heat fluxes with constant effective surface area. The proposed heat transfer evaluation scheme does not require a determination of the normal heat flux component or a surface area approximation on the boundary; thus, it is very efficient in curved-boundary simulations. Several numerical tests are conducted to validate the applicability and accuracy of the proposed heat transfer evaluation scheme, including: (i) two-dimensional (2D) steady-state thermal flow in a channel, (ii) one-dimensional (1D) transient heat conduction in an inclined semi-infinite solid, (iii) 2D transient heat conduction inside a circle, (iv) three-dimensional (3D) steady-state thermal flow in a circular pipe, and (v) 2D steady-state natural convection in a square enclosure with a circular cylinder at the center. Comparison between numerical results and analytical solutions in tests (i)–(iv) shows that the heat transfer is second-order accurate for straight boundaries perpendicular to one of the discrete lattice velocity vectors, and first-order accurate for curved boundaries due to the irregularly distributed lattice fractions intersected by the curved boundary. For test (v), the computed surface-averaged Nusselt numbers agree well with published results.


  • An Investigation of Pool Boiling Heat Transfer on Single Crystal Surfaces and a Dense Array of Cylindrical Cavities

    by Bradley Bon, James Klausner, Edward McKenna

    The pool boiling heat transfer characteristics of smooth single crystal and densely packed cylindrical cavity surfaces were investigated using two highly wetting fluids, perfluoro-n-hexane (FC-72) and n-hexane. Three single crystal copper surfaces and five undoped single crystal silicon surfaces with different plane orientations were considered. In addition, silicon surfaces with densely packed cylindrical cavities with diameters ranging from 9 to 75 μm, depth ranging from 9 to 20 μm, and spacing ranging from 75 to 600 μm were tested for comparison. It is observed that the copper single crystal surfaces show increasing heat transfer coefficient with decreasing atomic planar density. The single crystal silicon surfaces show increasing heat transfer coefficient with increasing atomic planar density. Plausible molecular scale mechanisms are discussed. In contrast, the silicon surfaces seeded with cylindrical cavities having diameters of 27 μm or less generally yield higher heat transfer coefficients than the single crystal silicon surfaces. A decrease in the cavity spacing results in a larger number of cavities on the surface, and the heat transfer coefficient increases as a result. Cavity depths of 6 and 20 μm result in the same heat transfer coefficient irrespective of cavity diameter. The nucleation site density for the cylindrical cavity surfaces is measured and reported at low superheat using a novel imaging technique.


  • Reactivity of Iron/Zirconia Powder in Fluidized Bed Thermochemical Hydrogen Production Reactors

    by F. Al-Raqom, J. F. Klausner

    A fluidized bed reactor has been developed which uses a two-step thermochemical water splitting process with a peak hydrogen production rate of 47 Ncm3/min.gFe at an oxidation temperature of 850 °C. Of particular interest, is that a mixture of iron and zirconia powder is fluidized during the oxidation reaction using a steam mass flux of 58 g/min-cm2. The zirconia powder serves to virtually eliminate iron powder sintering while maintaining a high reaction rate. The iron/zirconia powder is mixed in a ratio of 1:2 by apparent volume and has a mass ratio of 1:1. Both iron and zirconia particles are sieved to sizes ranging from 125 μm to 355 μm. The efficacy of zirconia as a sintering inhibitor was found to be dependent on the iron and zirconia mean particle size, particle size distribution and iron/zirconia apparent volume ratio. At 650 °C, the oxidation of iron powder with a mean particle size of 100 μm and a wide particle size distribution (40–250 μm) mixed with 44 μm zirconia powder with an iron/zirconia apparent volume ratio of 1:1 results in 75–90% sintering. In all cases, when iron is mixed with zirconia, the hydrogen production rate is not affected when compared with the pure iron case assuming an equivalent mass of iron is in the mixture. When iron powder is mixed with zirconia, both with a narrow particle size distribution (125–355 μm), the first oxidation step results in 3–7% sintering when the reactions are carried out at temperatures ranging between 840 and 895 °C. The hydrogen fractional yield is high (94–97%). For subsequent redox reactions, the macroscopic sintering is totally eliminated at 867 and 895 °C, although the hydrogen fractional yield decreases to 27 and 33%, respectively. It is demonstrated that mixing iron with zirconia in an equivalent mass ratio and similar particle size range can eliminate macroscopic sintering in a fluidized bed reactor at elevated temperatures up to 895 °C.


  • Supersonic Two-Phase Impinging Jet Heat Transfer

    by Richard R. Parker, James F. Klausner, Renwei Mei

    The experimental heat transfer rates from a supersonic two-phase impinging air jet with disperse droplets are presented. The experimental configuration consists of an expanding disperse mixture of air and water through a converging–diverging nozzle, designed for Mach 3.26 with a liquid to air mass flow ratio ranging from 1.28% to 3.83%, impinging upon a thin film heater constructed of nichrome. The spatially varying heat transfer coefficient is measured, and peak values are on the order of 200,000 W/m2K. Two distinct regions of heat transfer are identified, one dominated by the jet impingement flow and another dominated by thin film heat transfer. The heat transfer coefficient of an impinging jet with dry air and no droplets is measured during the investigation as well. The heat transfer results are compared, and it is demonstrated that the addition of disperse water droplets to the jet significantly increases the heat removal capability of the jet as well as smoothing the spatial temperature distribution of the heater surface. As much as an order of magnitude increase in heat transfer coefficient is observed near the centerline of the jet and a factor of 3–5 increase is seen at a distance of approximately 4 nozzle diameters from the jet. The fundamental heat transfer coefficient measurements should benefit applications involving supersonic two-phase jets for high heat flux thermal management.


  • Open Access

    Pool Boiling CHF for Pentane, Hexane, Methanol, FC-72, FC-87, and R113 on a Smooth Horizontal Surface

    by James Klausner, Cheng-Kang Guan, Renwei Mei

    A premiere free-access and peer-reviewed frontier journal site, serving the needs of the thermal-fluids community. See the latest research or submit an article. Quickly share your research with the global thermal-fluids community, for increased citations and impact at no cost.

  • Performance of Aluminum and Carbon Foams for Air Side Heat Transfer Augmentation

    by Patrick T. Garrity, James F. Klausner, Renwei Mei

    The air side heat transfer performance of three aluminum foam samples and three modified carbon foam samples are examined for comparison with multilouvered fins often found in compact heat exchangers. The aluminum foam samples have a bulk density of 216 kg/m3 with pore sizes of 0.5, 1, and 2 mm. The modified carbon foam samples have bulk densities of 284, 317, and 400 kg/m3 and machined flow passages of 3.2 mm in diameter. The samples were placed in a forced convection arrangement using a foil heater as the heat source and ambient air as the sink. A constant heat flux of 9.77 kW/m2 is applied throughout the experiments with the mean air velocity ranging from 1 to 6 m/s as the control parameter. The steady volume-averaged momentum equation and a two-equation nonequilibrium heat transfer model are employed to extract the volumetric heat transfer coefficients. Pressure drop measurements are correlated with the Darcy–Forcheimer relation. Empirical heat transfer correlations for the aluminum and carbon foam samples are provided. Using a hypothetical heat exchanger considering only the thermal resistance between the ambient air and the outer tube wall, the air side performance for each sample is modeled based on the local heat transfer coefficients and friction factors obtained from experiments. The performance of each sample is evaluated based on a coefficient of performance (COP, defined as the ratio of the total heat removed to the electrical input of the blower), compactness factor (CF, defined as the total heat removed per unit volume), and power density (PD, defined as the total heat removed per unit mass). Results show the carbon foam samples provide significant improvement in CF but the COP and PD are considerably lower than that for comparable multilouvered fin heat exchangers.


  • Diffusion Driven Desalination for Simultaneous Fresh Water Production and Desulfurization

    by Jameel R. Khan, James F. Klausner, Donald P. Ziegler, Srinivas S. Garimella

    The diffusion driven desalination (DDD) process has been previously introduced as a process for distilling water using low-grade waste heat. Here, a configuration of the DDD process is introduced for simultaneously distilling water and scrubbing sulfur dioxide (SO2) out of heated air streams, which is also known as flue gas desulfurization (FGD). This novel DDD/FGD process utilizes the low-grade waste heat carried in industrial discharge air streams. There are many applications, where the industrial air discharge also contains SO2, and in order to utilize the waste heat for the DDD process, the SO2 must be scrubbed out of the air stream. The two major components of the DDD process are the diffusion tower and the direct contact condenser. In the present work, a thermal fluid transport model for the DDD/FGD process, that includes SO2 scrubbing, is developed. It is an extension of the heat and mass transport model previously reported for the DDD process. An existing laboratory scale DDD facility was modified and tested with SO2 in the air stream and with seawater as the feed water to the diffusion tower. The experimental investigation has been completed to evaluate the fresh water production and SO2 scrubbing potential for the DDD/FGD process. The experimental results compare favorably with the model predictions. Chemical analysis on the condenser water demonstrates the capability of the DDD/FGD process to produce high quality fresh water using seawater as the input feed water to the process.