TLTrung Dung Le

Trung Dung Le

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Trung Dung Le has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Air-Core Dry-Type Shunt Reactor: Modeling and Inter-Turn Fault Detection

    by Giovanni Manassero, Fernanda Soares Vitor Petite, Trung Dung Le, Silvio Giuseppe Di Santo

    This study presents an integrated approach for detecting inter-turn faults in air-core dry-type shunt reactors. It combines finite-element modeling with a data-driven protection scheme that utilizes the eXtreme Gradient Boosting (XGBoost) algorithm. The method was applied to a 230 kV air-core reactor installed at the Penedo bus of the Nossa Senhora do Socorro-Penedo transmission line in Brazil. Finite-element analysis was used to determine the reactor's self and mutual inductances under various inter-turn fault conditions. These analyses served as the foundation for time-domain transient simulations. Fault signatures were generated using MATLAB, while external events, such as transmission line faults, busbar faults, reclosing operations, nearby equipment energization, line oscillations, and voltage unbalances, were simulated in ATP to enhance the model's security. The XGBoost-based protection scheme was trained and tested with both internal and external cases, including scenarios with noise, to evaluate its robustness. Results demonstrated high accuracy, dependability, and security, with most faults detected within two cycles. This proposed method effectively identifies inter-turn faults, even in situations where conventional protection schemes exhibit limited sensitivity.

  • A Physics-Informed-Neural-Network-Based State Estimator for Low Voltage Distribution Systems

    by Elio El Semaan, Alessio Iovine, Trung Dung Le, Philippe Dessante, Mouna Rifi, Dominique Croteau

    Due to the rising penetration of distributed energy resources and electric vehicles charging stations, Distribution System Operators (DSOs) are facing higher challenges to effectively manage low voltage (LV) grids. To enhance their voltage magnitudes’ real-time monitoring, distribution system state estimators (DSSEs) are the targeted solution. However, the application of conventional techniques for state estimation to LV grids is challenged by their unbalanced nature and the limited access to real-time measurements, while on the other hand state estimators (SEs) based on classical machine learning techniques are limited by a lack of knowledge of the physical aspect of the electrical systems. To address these issues, this paper proposes a physics-informed neural network (PINN) based LV DSSE using Graph Neural Networks (GNN). The proposed SE incorporates information about the grid’s topology and parameters while proposing a three-phase four-wire graph representation suitable for LV grids characteristics. Moreover, an unsupervised training is proposed with the aim of training the model in respect to the physical equations, among which the power flow equations. Tests are conducted on various grids generated from open data and evaluate the performance of the GNN-based SE while comparing it to classical machine learning based techniques as autoencoders (AE). The generalizability of the proposed SE in terms of training on a subset of grids and applying to others is investigated.


  • Contribution des moyens de production dispersés aux courants de défaut. Modélisation des moyens de production et algorithmes de détection de défaut.

    by Trung Dung Le

    Les travaux de la thèse se focalisent sur la protection des réseaux de distribution HTA en présence des générateurs distribués (éoliennes, fermes solaires,...). Dans un premier temps, un état de l’art a été réalisé sur les comportements des générateurs en creux de tension, leurs impacts sur le système de protection et les pistes de solution proposées pour y remédier. L’étape suivante est la mise au point d’algorithmes directionnels de détection de défauts, sans mesure de tension. Ces algorithmes s’appuient sur la décomposition en composantes symétriques des courants mesurés. Ces relais doivent empêcher le déclenchement intempestif de protections de surintensité dû au courant de défaut provenant des générateurs distribués. Ils sont moins coûteux par rapport à ceux traditionnels car les capteurs de tension, qui sont indispensables pour ces derniers, peuvent être enlevés. Après détection d’un défaut sur critère de seuil simple (max de I ou max de I résiduel), la direction est évaluée à l’aide d’un algorithme en delta basé sur les rapports courants inverse-homopolaire ou inverse-direct, selon le type de défaut (monophasé ou biphasé). En se basant sur ces rapports, un classifieur SVM (Support Vector Machines), entrainé préalablement à partir des simulations, donne ensuite l’estimation de la direction du défaut (amont ou aval par rapport au relais). La bonne performance de ces algorithmes a été montrée dans la thèse pour différents paramètres du réseau et en présence de différents types de générateurs. Le développement de tels algorithmes favorise la mise en œuvre des protections en réseau, qui pourraient être installées dans les futurs Smart Grids.

  • Deployability of a Probabilistic Earth Fault Location Method for MV Distribution Feeders

    by Alexandre Bach, Trung Dung Le, Marc Petit

    This paper presents a probabilistic impedance-based fault location method (FLM) designed for medium voltage (MV) distribution feeders using zero-sequence (ZS) components with few additional voltage measurements on secondary substations. It is based on a previous work in which a novel FLM has been developed and showed promising locating performance on the most challenging ramified rural feeders. However, this method has been found to be too sensitive to measurement errors to be deployable with the current generation of sensors. Thus, this paper presents a probabilistic formulation of the fault location problem with Monte-Carlo simulations which fits two four-dimensional Gaussian probability density functions (PDFs) of the ZS voltage and current on the considered paths (between the busbar and each measurement node) on a MV feeder. This way, our fault location algorithm is robust to both measurement and line impedance errors. A criterion for the optimal number of Monte-Carlo simulations as well as an efficient way to compute the similarity between two different PDFs in several dimensions are proposed. Finally, it is shown that the performances of this algorithm are highly correlated to the value of the threshold probability.


  • Open Access

    Sensitivity assessment of a novel earth fault location method with optimally placed distributed measurements for MV networks

    by Alexandre Bach, Trung Dung Le, Marc Petit

    This paper extends the study of a zero‐sequence impedance‐based fault location method (FLM) designed for medium voltage (MV) distribution feeders whose principle has been presented in a previous work Bach et al. This method is able to locate any type of earth fault with any type of neutral grounding inside a convex set of nodes forming the solution area. The total length of the lines inside this area is statistically computable a priori and depends only on the number and location of additional voltage measurements deployed on some remote end secondary substations. To be efficiently applied to the most challenging rural feeders presenting a lot of ramifications, simulations have shown a need for synchronized measurements, such as the ones obtained using phasor measurement units. Besides, this paper addresses the coupling potential of this method with more traditional ones such as Takagi‐based FLMs to enhance the performances of both, solving the multiple estimation problem while potentially locating the fault within one node. Finally, an extensive sensitivity analysis has been carried out, showing a good robustness with respect to impedance estimation errors or fault impedance values while showing the need for synchronization, especially on some remote measurement locations.


  • Fault current calculation in MTDC grids considering MMC blocking

    by Pascal Torwelle, Alberto Bertinato, Bertrand Raison, Trung Dung Le, Marc Petit


  • Open Access

    Characterization and Modeling of LV Cables Considering External Parameters for Distribution Networks

    by Ferréol Binot, Trung Dung Le, Marc Petit

    In response to the climate emergency, new uses are plugged to low voltage (LV) electrical networks. The development of self-consumption complicates the LV grid operation, and force distribution system operators (DSOs) to better model and characterize their networks. DSOs mainly use a three-conductor model (3 CM) to compute power flows, and consider error margins of 2% for voltage profiles to reflect their model inaccuracy. The characteristics of the future LV grids call into question these margins, and the models used. In this paper, a four-conductor model (4 CM), and an additional model named 4 CMext, that considers external parameters (i.e., cable temperature, ground electrical resistivity, and value/number of the earthing resistances) are proposed. The best model for cable characterization and voltage profile calculation is chosen; the 4 CMext is more adapted for the characterization, and corresponds with the finite element model, with an error margin of 4%, experimental measurements of 15%, and French cable manufacturer data of 0.5%. For the voltage profile, the 4 CMext provides a more detailed view of the critical cases that could lead to a violation of the limits of the EN 50160 standard than 3 CM and 4 CM. Violations of high or low voltages are underestimated by two to six times by the 3 CM and 4 CM. Not considering external parameters can lead to a voltage profile error of above 3%. In this paper, we recommend that DSOs use the 4 CMext to represent LV networks, which would allow LV networks to be used closer to their physical limits, and avoid or postpone network reinforcements.


  • Pre-Energization Concept for Overhead Lines in MTDC Grids Using DCCB Internal Capacitor

    by Pascal Torwelle, Alberto Bertinato, Wolfgang Grieshaber, Yang Yang, Bertrand Raison, Trung Dung Le, Marc Petit

    The integration of overhead lines in future MTDC grids leads to a higher fault rate compared to cables. Most of the faults are considered to be non-permanent, so that the line can be reconnected after dielectric recovery. The auto-reclosing procedure in HVDC systems reveals new challenges since multiple restrikes are possible within a short period of time. This paper proposes an auxiliary circuit for DC Circuit Breakers (DCCB) which enables to use the DCCB internal capacitor for the line pre-energization. A comprehensive description of the switchgear operations during the pre-energization sequence is provided and the fault property identification method is defined. The method is validated by simulations in a MTDC grid and a sensitivity analysis is carried out using EMTP-RV.