XWXiao-Ning Wang

Xiao-Ning Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao-Ning Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Machine learning-based analysis of MR radiomics can help to improve the diagnostic performance of PI-RADS v2 in clinically relevant prostate cancer

    by Jing Wang, Chen-Jiang Wu, Mei-Ling Bao, Jing Zhang, Xiao-Ning Wang, Yu-Dong Zhang

    Objective To investigate whether machine learning-based analysis of MR radiomics can help improve the performance PI-RADS v2 in clinically relevant prostate cancer (PCa). Methods This IRB-approved study included 54 patients with PCa undergoing multi-parametric (mp) MRI before prostatectomy. Imaging analysis was performed on 54 tumours, 47 normal peripheral (PZ) and 48 normal transitional (TZ) zone based on histological-radiological correlation. Mp-MRI was scored via PI-RADS, and quantified by measuring radiomic features. Predictive model was developed using a novel support vector machine trained with: (i) radiomics, (ii) PI-RADS scores, (iii) radiomics and PI-RADS scores. Paired comparison was made via ROC analysis. Results For PCa versus normal TZ, the model trained with radiomics had a significantly higher area under the ROC curve (Az) (0.955 [95% CI 0.923–0.976]) than PI-RADS (Az: 0.878 [0.834–0.914], p < 0.001). The Az between them was insignificant for PCa versus PZ (0.972 [0.945–0.988] vs. 0.940 [0.905–0.965], p = 0.097). When radiomics was added, performance of PI-RADS was significantly improved for PCa versus PZ (Az: 0.983 [0.960–0.995]) and PCa versus TZ (Az: 0.968 [0.940–0.985]). Conclusion Machine learning analysis of MR radiomics can help improve the performance of PI-RADS in clinically relevant PCa. Key Points • Machine-based analysis of MR radiomics outperformed in TZ cancer against PI-RADS. • Adding MR radiomics significantly improved the performance of PI-RADS. • DKI-derived Dapp and Kapp were two strong markers for the diagnosis of PCa.


  • Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality

    by Chen-Jiang Wu, Qing Wang, Jing Zhang, Xiao-Ning Wang, Xi-Sheng Liu, Yu-Dong Zhang, Hai-Bin Shi

    The purpose of this study was to compare the image quality of readout-segmented echo-planar imaging (RS-EPI) and that of standard single-shot echo-planar imaging (SS-EPI) in the kidney in a rat model. Twelve Wistar rats undergoing MRI examinations were imaged with two diffusion-weighted (DW) imaging protocols: a standard SS-EPI and a new RS-EPI protocol, both with a 1.0 × 1.0 × 3.0 mm voxel. The two groups of diffusion-weighted images were independently scored on geometric distortion, image blurring, signal dropout, and the overall image quality by two radiologists. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) were measured on both sequences. Inter-rater agreement (IRA) was evaluated by Fleiss kappa (κ) and inter-class correlation coefficient (ICC) statistics. Comparisons of image qualities were made by Wilcoxon signed-rank test and paired-sample t test. Both RS-EPI and SS-EPI had good IRAs in scoring image qualities (κ = 0.607–0.833) and measuring renal ADCs (ICC = 0.828–0.945). Compared to SS-EPI, RS-EPI produced less geometric distortion (median score 1.5 versus 2.5, p < 0.0001), less image blurring (1.75 versus 2.0, p = 0.0003), less signal dropout (1.0 versus 3.0, p = 0.0001), and a lower score in overall image artifacts (4.25 versus 7.25; p < 0.0001). RS-EPI had higher SNR of renal DW images than SS-EPI (p < 0.001). The intra-variability of ADCs in cortex, outer medulla, and inner medulla ranged from 9.6 % to 11.1 % (Pearson correlation coefficient ρ = 0.675–0.729; p < 0.001) between the two protocols. We showed that for DWI of the kidney at 1.0 × 1.0 × 3.0 mm3 voxel sizes, the new protocol provided better image quality than standard SS-EPI protocol.


  • Feasibility study of high-resolution DCE-MRI for glomerular filtration rate (GFR) measurement in a routine clinical modal

    by Yu-Dong Zhang, Chen-Jiang Wu, Jing Zhang, Xiao-Ning Wang, Xi-Sheng Liu, Hai-Bin Shi


  • DWI-associated entire-tumor histogram analysis for the differentiation of low-grade prostate cancer from intermediate–high-grade prostate cancer

    by Chen-Jiang Wu, Qing Wang, Hai Li, Xiao-Ning Wang, Xi-Sheng Liu, Hai-Bin Shi, Yu-Dong Zhang

    Purpose To investigate diagnostic efficiency of DWI using entire-tumor histogram analysis in differentiating the low-grade (LG) prostate cancer (PCa) from intermediate–high-grade (HG) PCa in comparison with conventional ROI-based measurement. Methods DW images (b of 0–1400 s/mm2) from 126 pathology-confirmed PCa (diameter >0.5 cm) in 110 patients were retrospectively collected and processed by mono-exponential model. The measurement of tumor apparent diffusion coefficients (ADCs) was performed with using histogram-based and ROI-based approach, respectively. The diagnostic ability of ADCs from two methods for differentiating LG-PCa (Gleason score, GS ≤6) from HG-PCa (GS > 6) was determined by ROC regression, and compared by McNemar’s test. Results There were 49 LG-tumor and 77 HG-tumor at pathologic findings. Histogram-based ADCs (mean, median, 10th and 90th) and ROI-based ADCs (mean) showed dominant relationships with ordinal GS of Pca (ρ = −0.225 to −0.406, p < 0.05). All above imaging indices reflected significant difference between LG-PCa and HG-PCa (all p values p < 0.01), but lower sensitivity (57.1%–71.3% vs. 84.4%, p < 0.05) than ROI-based ADCs in differentiating LG-PCa from HG-PCa. Conclusions DWI-associated histogram analysis had higher specificity, Az, Youden index, and LR+ for differentiation of PCa Gleason grade than ROI-based approach.


  • The Histogram Analysis of Diffusion-Weighted Intravoxel Incoherent Motion (IVIM) Imaging for Differentiating the Gleason grade of Prostate Cancer

    by Yu-Dong Zhang, Qing Wang, Chen-Jiang Wu, Xiao-Ning Wang, Jing Zhang, Hui Liu, Xi-Sheng Liu, Hai-Bin Shi

    To evaluate histogram analysis of intravoxel incoherent motion (IVIM) for discriminating the Gleason grade of prostate cancer (PCa). A total of 48 patients pathologically confirmed as having clinically significant PCa (size > 0.5 cm) underwent preoperative DW-MRI (b of 0–900 s/mm2). Data was post-processed by monoexponential and IVIM model for quantitation of apparent diffusion coefficients (ADCs), perfusion fraction f, diffusivity D and pseudo-diffusivity D*. Histogram analysis was performed by outlining entire-tumour regions of interest (ROIs) from histological–radiological correlation. The ability of imaging indices to differentiate low-grade (LG, Gleason score (GS) ≤6) from intermediate/high-grade (HG, GS > 6) PCa was analysed by ROC regression. Eleven patients had LG tumours (18 foci) and 37 patients had HG tumours (42 foci) on pathology examination. HG tumours had significantly lower ADCs and D in terms of mean, median, 10th and 75th percentiles, combined with higher histogram kurtosis and skewness for ADCs, D and f, than LG PCa (p < 0.05). Histogram D showed relatively higher correlations (ñ = 0.641–0.668 vs. ADCs: 0.544–0.574) with ordinal GS of PCa; and its mean, median and 10th percentile performed better than ADCs did in distinguishing LG from HG PCa. It is feasible to stratify the pathological grade of PCa by IVIM with histogram metrics. D performed better in distinguishing LG from HG tumour than conventional ADCs. • GS had relatively higher correlation with tumour D than ADCs. • Difference of histogram D among two-grade tumours was statistically significant. • D yielded better individual features in demonstrating tumour grade than ADC. • D* and f failed to determine tumour grade of PCa.