Hai-Bin Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hai-Bin Shi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Chen-Jiang Wu
Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
6 shared publications - Yu-Dong Zhang
Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
4 shared publications - Xi-Sheng Liu
Department of Radiology, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
3 shared publications - Xiao-Ning Wang
Department of Radiology, The First Affiliated Hospital with Nanjing Medical University, No. 300, Guangzhou Road, Nanjing, 210000, China.
3 shared publications Yu-Dong Zhang
Department of Radiology, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
3 shared publicationsHai Li
Department of Pathology, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
2 shared publications
Latest Publications
- Open Access
- 15 August 2016
- Published by Impact Journals, LLC in Oncotarget
- Vol. 7 (47) , 78140-78151
An imaging-based approach predicts clinical outcomes in prostate cancer through a novel support vector machine classification
Preoperatively predict the probability of Prostate cancer (PCa) biochemical recurrence (BCR) is of definite clinical relevance. The purpose of this study was to develop an imaging-based approach in the prediction of 3-years BCR through a novel support vector machine (SVM) classification. We collected clinicopathologic and MR imaging datasets in 205 patients pathologically confirmed PCa after radical prostatectomy. Univariable and multivariable analyses were used to assess the association between MR findings and 3-years BCR, and modeled the imaging variables and follow-up data to predict 3-year PCa BCR using SVM analysis. The performance of SVM was compared with conventional Logistic regression (LR) and D’Amico risk stratification scheme by area under the receiver operating characteristic curve (Az) analysis. We found that SVM had significantly higher Az (0.959 vs. 0.886; p = 0.007), sensitivity (93.3% vs. 83.3%; p = 0.025), specificity (91.7% vs. 77.2%; p = 0.009) and accuracy (92.2% vs. 79.0%; p = 0.006) than LR analysis. Performance of popularized D’Amico scheme was effectively improved by adding MRI-derived variables (Az: 0.970 vs. 0.859, p < 0.001; sensitivity: 91.7% vs. 86.7%, p = 0.031; specificity: 94.5% vs. 78.6%, p = 0.001; and accuracy: 93.7% vs. 81.0%, p = 0.007). Additionally, beside pathological Gleason score (hazard ratio [HR] = 1.560, p = 0.008), surgical-T3b (HR = 4.525, p < 0.001) and positive surgical margin (HR = 1.314, p = 0.007), apparent diffusion coefficient (HR = 0.149, p = 0.035) was the only independent imaging predictor of time to PSA failure. Therefore, We concluded that imaging-based approach using SVM was superior to LR analysis in predicting PCa outcome. Adding MR variables improved the performance of D’Amico scheme.
- 15 August 2016
- Published by Impact Journals, LLC in Oncotarget
- Vol. 7 (47) , 78140-78151
Open AccessAn imaging-based approach predicts clinical outcomes in prostate cancer through a novel support vector machine classification
Preoperatively predict the probability of Prostate cancer (PCa) biochemical recurrence (BCR) is of definite clinical relevance. The purpose of this study was to develop an imaging-based approach in the prediction of 3-years BCR through a novel support vector machine (SVM) classification. We collected clinicopathologic and MR imaging datasets in 205 patients pathologically confirmed PCa after radical prostatectomy. Univariable and multivariable analyses were used to assess the association between MR findings and 3-years BCR, and modeled the imaging variables and follow-up data to predict 3-year PCa BCR using SVM analysis. The performance of SVM was compared with conventional Logistic regression (LR) and D’Amico risk stratification scheme by area under the receiver operating characteristic curve (Az) analysis. We found that SVM had significantly higher Az (0.959 vs. 0.886; p = 0.007), sensitivity (93.3% vs. 83.3%; p = 0.025), specificity (91.7% vs. 77.2%; p = 0.009) and accuracy (92.2% vs. 79.0%; p = 0.006) than LR analysis. Performance of popularized D’Amico scheme was effectively improved by adding MRI-derived variables (Az: 0.970 vs. 0.859, p < 0.001; sensitivity: 91.7% vs. 86.7%, p = 0.031; specificity: 94.5% vs. 78.6%, p = 0.001; and accuracy: 93.7% vs. 81.0%, p = 0.007). Additionally, beside pathological Gleason score (hazard ratio [HR] = 1.560, p = 0.008), surgical-T3b (HR = 4.525, p < 0.001) and positive surgical margin (HR = 1.314, p = 0.007), apparent diffusion coefficient (HR = 0.149, p = 0.035) was the only independent imaging predictor of time to PSA failure. Therefore, We concluded that imaging-based approach using SVM was superior to LR analysis in predicting PCa outcome. Adding MR variables improved the performance of D’Amico scheme.
- 9 August 2016
- Published by Springer Nature in Abdominal Radiology
- Vol. 42 (1) , 226-235
Feasibility of triphasic CT with a modified two-point Patlak plot to determine spit kidney glomerular filtration rate in clinical practice
Purpose To investigate whether triphasic CT with a simplified Patlak plot can be used in clinical practice for the estimate of split kidney glomerular filtration rate (SKGFR). Materials and methods The animal experiment included 15 rabbits that underwent 40 dynamic contrast-enhanced CT scans of the kidneys with 1.5 s time interval. Patlak-derived SKGFR was obtained using standard forty-point, two-point (unenhanced phase, arterial phase t α, and portovenous phase t β), and a modified two-point (MTP) (unenhanced, t α, t β, and a virtual t τ [t τ = (t α + t β)/2]) image data, respectively. The MTP-Patlak plot approach was then validated in 13 patients who underwent a triphasic renal contrast-enhanced CT examination. SKGFR measured by 99mTc-DTPA clearance was as a standard reference. Results MTP-Patlak significantly reduced input function errors than two-point Patlak (21.1 ± 16.2 % vs 30.8 ± 15.2 %, p < 0.01) and showed good concordance with standard Patlak for measurement of SKGFR in animal experiment (1.20 ± 0.38 mL/g/min vs 1.51 ± 0.43 mL/g/min; linear correlation coefficient r = 0.87, p < 0.001). Human study showed that mean SKGFR was 45.7 mL/min (range, 26.5–86.2 mL/min) obtained from 99mTc-DTPA, and 38.2 mL/min (range, 18.6–79.3 mL/min) obtained from triphasic CT using MTP-Patlak plot. Linear correlation between the two methods was r = 0.75 (p < 0.01). The mean difference between SKGFRs as determined with the two methods was 7.4 ± 9.0 mL/min. Conclusion The MTP-Patlak approach, featured with simplicity, is feasible in a clinically indicated CT examination for the evaluation of split renal function.
- 9 August 2016
- Published by Springer Nature in Abdominal Radiology
- Vol. 42 (1) , 226-235
Feasibility of triphasic CT with a modified two-point Patlak plot to determine spit kidney glomerular filtration rate in clinical practice
Purpose To investigate whether triphasic CT with a simplified Patlak plot can be used in clinical practice for the estimate of split kidney glomerular filtration rate (SKGFR). Materials and methods The animal experiment included 15 rabbits that underwent 40 dynamic contrast-enhanced CT scans of the kidneys with 1.5 s time interval. Patlak-derived SKGFR was obtained using standard forty-point, two-point (unenhanced phase, arterial phase t α, and portovenous phase t β), and a modified two-point (MTP) (unenhanced, t α, t β, and a virtual t τ [t τ = (t α + t β)/2]) image data, respectively. The MTP-Patlak plot approach was then validated in 13 patients who underwent a triphasic renal contrast-enhanced CT examination. SKGFR measured by 99mTc-DTPA clearance was as a standard reference. Results MTP-Patlak significantly reduced input function errors than two-point Patlak (21.1 ± 16.2 % vs 30.8 ± 15.2 %, p < 0.01) and showed good concordance with standard Patlak for measurement of SKGFR in animal experiment (1.20 ± 0.38 mL/g/min vs 1.51 ± 0.43 mL/g/min; linear correlation coefficient r = 0.87, p < 0.001). Human study showed that mean SKGFR was 45.7 mL/min (range, 26.5–86.2 mL/min) obtained from 99mTc-DTPA, and 38.2 mL/min (range, 18.6–79.3 mL/min) obtained from triphasic CT using MTP-Patlak plot. Linear correlation between the two methods was r = 0.75 (p < 0.01). The mean difference between SKGFRs as determined with the two methods was 7.4 ± 9.0 mL/min. Conclusion The MTP-Patlak approach, featured with simplicity, is feasible in a clinically indicated CT examination for the evaluation of split renal function.
- 1 August 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (2) , 330-338
New RESOLVE-Based Diffusional Kurtosis Imaging in MRI-Visible Prostate Cancer: Effect of Reduced b Value on Image Quality and Diagnostic Effectiveness
OBJECTIVE. The purpose of this article was to investigate whether a new readout segmentation of long variable echo-trains (RESOLVE)–based diffusional kurtosis imaging (DKI) with reduced b value technique can affect image quality and diagnostic effectiveness in MRI-visible prostate cancer (PCA). SUBJECTS AND METHODS. Prostatic RESOLVE DKI (0–1400 s/mm2) was prospectively performed for 12 volunteers. The optimal protocol was then performed in 108 MRI-visible PCAs to determine whether it can compete against a preferred b-value set (0–2000 s/mm2) regarding image quality and diagnostic effectiveness. Images were interpreted by two independent radiologists using the prostate imaging reporting and data system (PI-RADS). Readers' concordance and diagnostic effectiveness were tested with the Fleiss kappa and area under the ROC curve (Az) analyses. RESULTS. A b value of 1400 s/mm2 generated a larger apparent diffusion coefficient of gaussian distribution (Dapp) (1.35 ± 0.31 vs 1.30 ± 0.30 mm2/s; p < 0.001) and appa...
- 1 August 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (2) , 330-338
New RESOLVE-Based Diffusional Kurtosis Imaging in MRI-Visible Prostate Cancer: Effect of Reduced b Value on Image Quality and Diagnostic Effectiveness
OBJECTIVE. The purpose of this article was to investigate whether a new readout segmentation of long variable echo-trains (RESOLVE)–based diffusional kurtosis imaging (DKI) with reduced b value technique can affect image quality and diagnostic effectiveness in MRI-visible prostate cancer (PCA). SUBJECTS AND METHODS. Prostatic RESOLVE DKI (0–1400 s/mm2) was prospectively performed for 12 volunteers. The optimal protocol was then performed in 108 MRI-visible PCAs to determine whether it can compete against a preferred b-value set (0–2000 s/mm2) regarding image quality and diagnostic effectiveness. Images were interpreted by two independent radiologists using the prostate imaging reporting and data system (PI-RADS). Readers' concordance and diagnostic effectiveness were tested with the Fleiss kappa and area under the ROC curve (Az) analyses. RESULTS. A b value of 1400 s/mm2 generated a larger apparent diffusion coefficient of gaussian distribution (Dapp) (1.35 ± 0.31 vs 1.30 ± 0.30 mm2/s; p < 0.001) and appa...
- 1 March 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (3) , 344-352
Liver Imaging Reporting and Data System:
- 1 March 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (3) , 344-352
Liver Imaging Reporting and Data System:
- 22 December 2015
- Published by Springer Nature in Abdominal Radiology
- Vol. 41 (1) , 100-108
Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
The purpose of this study was to compare the image quality of readout-segmented echo-planar imaging (RS-EPI) and that of standard single-shot echo-planar imaging (SS-EPI) in the kidney in a rat model. Twelve Wistar rats undergoing MRI examinations were imaged with two diffusion-weighted (DW) imaging protocols: a standard SS-EPI and a new RS-EPI protocol, both with a 1.0 × 1.0 × 3.0 mm voxel. The two groups of diffusion-weighted images were independently scored on geometric distortion, image blurring, signal dropout, and the overall image quality by two radiologists. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) were measured on both sequences. Inter-rater agreement (IRA) was evaluated by Fleiss kappa (κ) and inter-class correlation coefficient (ICC) statistics. Comparisons of image qualities were made by Wilcoxon signed-rank test and paired-sample t test. Both RS-EPI and SS-EPI had good IRAs in scoring image qualities (κ = 0.607–0.833) and measuring renal ADCs (ICC = 0.828–0.945). Compared to SS-EPI, RS-EPI produced less geometric distortion (median score 1.5 versus 2.5, p < 0.0001), less image blurring (1.75 versus 2.0, p = 0.0003), less signal dropout (1.0 versus 3.0, p = 0.0001), and a lower score in overall image artifacts (4.25 versus 7.25; p < 0.0001). RS-EPI had higher SNR of renal DW images than SS-EPI (p < 0.001). The intra-variability of ADCs in cortex, outer medulla, and inner medulla ranged from 9.6 % to 11.1 % (Pearson correlation coefficient ρ = 0.675–0.729; p < 0.001) between the two protocols. We showed that for DWI of the kidney at 1.0 × 1.0 × 3.0 mm3 voxel sizes, the new protocol provided better image quality than standard SS-EPI protocol.
- 22 December 2015
- Published by Springer Nature in Abdominal Radiology
- Vol. 41 (1) , 100-108
Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
The purpose of this study was to compare the image quality of readout-segmented echo-planar imaging (RS-EPI) and that of standard single-shot echo-planar imaging (SS-EPI) in the kidney in a rat model. Twelve Wistar rats undergoing MRI examinations were imaged with two diffusion-weighted (DW) imaging protocols: a standard SS-EPI and a new RS-EPI protocol, both with a 1.0 × 1.0 × 3.0 mm voxel. The two groups of diffusion-weighted images were independently scored on geometric distortion, image blurring, signal dropout, and the overall image quality by two radiologists. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) were measured on both sequences. Inter-rater agreement (IRA) was evaluated by Fleiss kappa (κ) and inter-class correlation coefficient (ICC) statistics. Comparisons of image qualities were made by Wilcoxon signed-rank test and paired-sample t test. Both RS-EPI and SS-EPI had good IRAs in scoring image qualities (κ = 0.607–0.833) and measuring renal ADCs (ICC = 0.828–0.945). Compared to SS-EPI, RS-EPI produced less geometric distortion (median score 1.5 versus 2.5, p < 0.0001), less image blurring (1.75 versus 2.0, p = 0.0003), less signal dropout (1.0 versus 3.0, p = 0.0001), and a lower score in overall image artifacts (4.25 versus 7.25; p < 0.0001). RS-EPI had higher SNR of renal DW images than SS-EPI (p < 0.001). The intra-variability of ADCs in cortex, outer medulla, and inner medulla ranged from 9.6 % to 11.1 % (Pearson correlation coefficient ρ = 0.675–0.729; p < 0.001) between the two protocols. We showed that for DWI of the kidney at 1.0 × 1.0 × 3.0 mm3 voxel sizes, the new protocol provided better image quality than standard SS-EPI protocol.
- 1 October 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (8) , 978-983
Feasibility study of high-resolution DCE-MRI for glomerular filtration rate (GFR) measurement in a routine clinical modal
- 1 October 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (8) , 978-983
Feasibility study of high-resolution DCE-MRI for glomerular filtration rate (GFR) measurement in a routine clinical modal
- 9 July 2015
- Published by Springer Nature in Abdominal Radiology
- Vol. 40 (8) , 3214-3221
DWI-associated entire-tumor histogram analysis for the differentiation of low-grade prostate cancer from intermediate–high-grade prostate cancer
Purpose To investigate diagnostic efficiency of DWI using entire-tumor histogram analysis in differentiating the low-grade (LG) prostate cancer (PCa) from intermediate–high-grade (HG) PCa in comparison with conventional ROI-based measurement. Methods DW images (b of 0–1400 s/mm2) from 126 pathology-confirmed PCa (diameter >0.5 cm) in 110 patients were retrospectively collected and processed by mono-exponential model. The measurement of tumor apparent diffusion coefficients (ADCs) was performed with using histogram-based and ROI-based approach, respectively. The diagnostic ability of ADCs from two methods for differentiating LG-PCa (Gleason score, GS ≤6) from HG-PCa (GS > 6) was determined by ROC regression, and compared by McNemar’s test. Results There were 49 LG-tumor and 77 HG-tumor at pathologic findings. Histogram-based ADCs (mean, median, 10th and 90th) and ROI-based ADCs (mean) showed dominant relationships with ordinal GS of Pca (ρ = −0.225 to −0.406, p < 0.05). All above imaging indices reflected significant difference between LG-PCa and HG-PCa (all p values p < 0.01), but lower sensitivity (57.1%–71.3% vs. 84.4%, p < 0.05) than ROI-based ADCs in differentiating LG-PCa from HG-PCa. Conclusions DWI-associated histogram analysis had higher specificity, Az, Youden index, and LR+ for differentiation of PCa Gleason grade than ROI-based approach.
- 9 July 2015
- Published by Springer Nature in Abdominal Radiology
- Vol. 40 (8) , 3214-3221
DWI-associated entire-tumor histogram analysis for the differentiation of low-grade prostate cancer from intermediate–high-grade prostate cancer
Purpose To investigate diagnostic efficiency of DWI using entire-tumor histogram analysis in differentiating the low-grade (LG) prostate cancer (PCa) from intermediate–high-grade (HG) PCa in comparison with conventional ROI-based measurement. Methods DW images (b of 0–1400 s/mm2) from 126 pathology-confirmed PCa (diameter >0.5 cm) in 110 patients were retrospectively collected and processed by mono-exponential model. The measurement of tumor apparent diffusion coefficients (ADCs) was performed with using histogram-based and ROI-based approach, respectively. The diagnostic ability of ADCs from two methods for differentiating LG-PCa (Gleason score, GS ≤6) from HG-PCa (GS > 6) was determined by ROC regression, and compared by McNemar’s test. Results There were 49 LG-tumor and 77 HG-tumor at pathologic findings. Histogram-based ADCs (mean, median, 10th and 90th) and ROI-based ADCs (mean) showed dominant relationships with ordinal GS of Pca (ρ = −0.225 to −0.406, p < 0.05). All above imaging indices reflected significant difference between LG-PCa and HG-PCa (all p values p < 0.01), but lower sensitivity (57.1%–71.3% vs. 84.4%, p < 0.05) than ROI-based ADCs in differentiating LG-PCa from HG-PCa. Conclusions DWI-associated histogram analysis had higher specificity, Az, Youden index, and LR+ for differentiation of PCa Gleason grade than ROI-based approach.