Edward Barbour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Edward Barbour has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Ian Allan Grant Wilson
University of Birmingham, Birmingham, United Kingdom
6 shared publications - Bruno Cardenas
Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
4 shared publications - Daniel Pottie
Centre for Renewable Energy Systems Technology Loughborough University Loughborough UK
4 shared publications - David Parra
Energy Efficiency Group, Institute for Environmental Sciences and Forel Institute, University of Geneva, Boulevard Carl-Vogt 66, 1205 Genève, Switzerland
4 shared publications - Alejandro Pena-Bello
Institute of Energy and Environment, School of Engineering, University of Applied Sciences of Western Switzerland HES-SO, 1951, Sion, Switzerland
2 shared publications - Ian G. Bryden
The University of Edinburgh
2 shared publications
Latest Publications
- Open Access
- 22 February 2025
- Published by Elsevier in Technology in Society
- Vol. 81
Feeling the heat: Understanding stakeholders’ perceptions of residential-sector heating decarbonisation options in the UK
- 22 February 2025
- Published by Elsevier in Technology in Society
- Vol. 81
Open AccessFeeling the heat: Understanding stakeholders’ perceptions of residential-sector heating decarbonisation options in the UK
- Open Access
- 3 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Exergy analysis of isochoric and isobaric adiabatic compressed air energy storage
Adiabatic compressed air energy storage (ACAES) is an energy storage technology that has the potential to play an important role in the transition to a predominantly renewables‐driven net‐zero energy system. However, it has not yet achieved the performance necessary to be widely deployed. This paper undertakes an exergy analysis of isobaric and isochoric ACAES systems, tracking lost work through the components and exploring the influences of different design choices. Three different configurations are modelled: (1) 3 compression and 3 expansion stages; (2) 4 compression and 2 expansion stages; and (3) 2 compression and 4 expansion stages. These results illustrate that isobaric systems are likely to have higher round‐trip efficiency and significantly higher energy density, at the cost of achieving isobaric storage. Exergy analysis reveals that most of the losses arise in the compressors, compressor aftercoolers and expanders. Losses in aftercoolers are exaggerated when compressors operate with high‐pressure ratios, emphasizing that the choice of TES is a key system variable. With pressurised water as the coolant and TES fluid, it seems likely that the best system will have more compression than expansion stages. Increasing the number of compression stages decreases the off‐design penalty when the system is isochoric.
- 3 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessExergy analysis of isochoric and isobaric adiabatic compressed air energy storage
Adiabatic compressed air energy storage (ACAES) is an energy storage technology that has the potential to play an important role in the transition to a predominantly renewables‐driven net‐zero energy system. However, it has not yet achieved the performance necessary to be widely deployed. This paper undertakes an exergy analysis of isobaric and isochoric ACAES systems, tracking lost work through the components and exploring the influences of different design choices. Three different configurations are modelled: (1) 3 compression and 3 expansion stages; (2) 4 compression and 2 expansion stages; and (3) 2 compression and 4 expansion stages. These results illustrate that isobaric systems are likely to have higher round‐trip efficiency and significantly higher energy density, at the cost of achieving isobaric storage. Exergy analysis reveals that most of the losses arise in the compressors, compressor aftercoolers and expanders. Losses in aftercoolers are exaggerated when compressors operate with high‐pressure ratios, emphasizing that the choice of TES is a key system variable. With pressurised water as the coolant and TES fluid, it seems likely that the best system will have more compression than expansion stages. Increasing the number of compression stages decreases the off‐design penalty when the system is isochoric.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Design of a Combined Heat Store and Heat Exchanger for CAES Systems
A combined heat store and heat exchanger unit (HSX) intended for compressed air energy storage (CAES) is presented. The unit is directly charged by the pressurised air emerging from the compression train, which removes the need for a secondary low‐pressure air circuit. Salt is used as the thermal storage medium due to its good heat capacity, thermal conductivity, and its ability to accommodate the thermal expansion of the stainless‐steel pipes. This paper uses a CAES system (15 MW, 12‐h discharge) driven by an offshore wind turbine as a case study. There are not many commercial CAES systems in operation; however, the levelized cost of the heat storage subsystem of a CAES system (i.e. heat store, set of heat exchangers and ancillary low‐pressure circuit) ranges between 45 and 48 £/MWh. Findings show that the most cost‐effective design for a HSX has a capital cost of ∼£55k. This translates into a levelized cost of storage of ∼31.5 £/MWh. The roundtrip exergy efficiency of this design is 93.7 %. This accounts for heat‐exergy and pressure‐exergy losses; losses to ambient are not considered. A HSX unit can considerably reduce the overall cost of a CAES system.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessDesign of a Combined Heat Store and Heat Exchanger for CAES Systems
A combined heat store and heat exchanger unit (HSX) intended for compressed air energy storage (CAES) is presented. The unit is directly charged by the pressurised air emerging from the compression train, which removes the need for a secondary low‐pressure air circuit. Salt is used as the thermal storage medium due to its good heat capacity, thermal conductivity, and its ability to accommodate the thermal expansion of the stainless‐steel pipes. This paper uses a CAES system (15 MW, 12‐h discharge) driven by an offshore wind turbine as a case study. There are not many commercial CAES systems in operation; however, the levelized cost of the heat storage subsystem of a CAES system (i.e. heat store, set of heat exchangers and ancillary low‐pressure circuit) ranges between 45 and 48 £/MWh. Findings show that the most cost‐effective design for a HSX has a capital cost of ∼£55k. This translates into a levelized cost of storage of ∼31.5 £/MWh. The roundtrip exergy efficiency of this design is 93.7 %. This accounts for heat‐exergy and pressure‐exergy losses; losses to ambient are not considered. A HSX unit can considerably reduce the overall cost of a CAES system.
- Open Access
- 25 June 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-14
Numerical investigation of module-level inhomogeneous ageing in lithium-ion batteries from temperature gradients and electrical connection topologies
The distribution of current/voltage can be further regulated by optimising the electrical connection topology, considering a particular battery thermal management systems. This study numerically investigates a 4P6S battery module with two connection topologies: 1) a straight connection topology, where the sub-modules consist of parallel-connected cells that are serial connected in a linear configuration, and 2) a parallelogram connection topology, where the sub-modules are serial connected in a parallelogram configuration. We find that the straight topology is more advantageous, as it allows the temperature gradient to be distributed among the parallel-connected cells in the sub-modules, mitigating over(dis)charging. Consequently, it achieves a 0.8% higher effective capacity than the parallelogram topology at 1C discharge, along with a higher state of health at 80.15% compared to 80% for the parallelogram topology. Notably, the straight topology results in a maximum current maldistribution of 0.24C at 1C discharge, which is considered an acceptable trade-off.
- 25 June 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-14
Open AccessNumerical investigation of module-level inhomogeneous ageing in lithium-ion batteries from temperature gradients and electrical connection topologies
The distribution of current/voltage can be further regulated by optimising the electrical connection topology, considering a particular battery thermal management systems. This study numerically investigates a 4P6S battery module with two connection topologies: 1) a straight connection topology, where the sub-modules consist of parallel-connected cells that are serial connected in a linear configuration, and 2) a parallelogram connection topology, where the sub-modules are serial connected in a parallelogram configuration. We find that the straight topology is more advantageous, as it allows the temperature gradient to be distributed among the parallel-connected cells in the sub-modules, mitigating over(dis)charging. Consequently, it achieves a 0.8% higher effective capacity than the parallelogram topology at 1C discharge, along with a higher state of health at 80.15% compared to 80% for the parallelogram topology. Notably, the straight topology results in a maximum current maldistribution of 0.24C at 1C discharge, which is considered an acceptable trade-off.
- Open Access
Comparative Analysis of Isochoric and Isobaric Adiabatic Compressed Air Energy Storage
Adiabatic Compressed Air Energy Storage (ACAES) is regarded as a promising, grid scale, medium-to-long duration energy storage technology. In ACAES, the air storage may be isochoric (constant volume) or isobaric (constant pressure). Isochoric storage, wherein the internal pressure cycles between an upper and lower limit as the system charges and discharges is mechanically simpler, however, it leads to undesirable thermodynamic consequences which are detrimental to the ACAES overall performance. Isobaric storage can be a valuable alternative: the storage volume varies to offset the pressure and temperature changes that would otherwise occur as air mass enters or leaves the high-pressure storage. In this paper we develop a thermodynamic model based on expected ACAES and existing CAES system features to compare the effects of isochoric and isobaric storage. Importantly, off-design compressor performance due to the sliding storage pressure is included by using a second degree polynomial fit for the isentropic compressor efficiency. For our modelled systems, the isobaric system round-trip efficiency (RTE) reaches 61.5%. The isochoric system achieves 57.8% even when no compressor off-design performance decrease is taken into account. This fact is associated to inherent losses due to throttling and mixing of heat stored at different temperatures. In our base-case scenario where the isentropic compressor efficiency varies between and , the isochoric system RTE is approximately 10% lower than the isobaric. These results indicate that isobaric storage for CAES is worth further development. We suggest that subsequent work investigate the exergy flows as well as the scalability challenges with isobaric storage mechanisms.Open AccessComparative Analysis of Isochoric and Isobaric Adiabatic Compressed Air Energy Storage
Adiabatic Compressed Air Energy Storage (ACAES) is regarded as a promising, grid scale, medium-to-long duration energy storage technology. In ACAES, the air storage may be isochoric (constant volume) or isobaric (constant pressure). Isochoric storage, wherein the internal pressure cycles between an upper and lower limit as the system charges and discharges is mechanically simpler, however, it leads to undesirable thermodynamic consequences which are detrimental to the ACAES overall performance. Isobaric storage can be a valuable alternative: the storage volume varies to offset the pressure and temperature changes that would otherwise occur as air mass enters or leaves the high-pressure storage. In this paper we develop a thermodynamic model based on expected ACAES and existing CAES system features to compare the effects of isochoric and isobaric storage. Importantly, off-design compressor performance due to the sliding storage pressure is included by using a second degree polynomial fit for the isentropic compressor efficiency. For our modelled systems, the isobaric system round-trip efficiency (RTE) reaches 61.5%. The isochoric system achieves 57.8% even when no compressor off-design performance decrease is taken into account. This fact is associated to inherent losses due to throttling and mixing of heat stored at different temperatures. In our base-case scenario where the isentropic compressor efficiency varies between and , the isochoric system RTE is approximately 10% lower than the isobaric. These results indicate that isobaric storage for CAES is worth further development. We suggest that subsequent work investigate the exergy flows as well as the scalability challenges with isobaric storage mechanisms. - Open Access
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Segmentation of household smart meter data linked to PV and battery value
The primary challenge with big smart meter data is to gain actionable insights which ultimately enhance the sustainability of the power network. In this paper, we analyze 1 year of smart meter data from 326 households in Austin, TX. Via clustering, we find distinct daily usage patterns, illustrating heterogeneous consumption behavior which changes throughout the year. However, most consumers have at least 56% of days explained by 3 out of 24 identified load types. For each load type we estimate the value of PV and batteries under flat rate and Time-Of-Use electricity tariffs. We find that knowledge of a consumers most common load shapes can significantly improve estimates for PV viability compared to a control estimate based on population-wide averages. However, knowledge of the most common load shapes does not improve estimates of battery viability unless electricity prices are time-varying. This highlights that, in general, the information contained by load shape clusters is of high value when consumers face economic choices that depend on the timing of their consumption. This work builds on current knowledge by explicitly linking smart meter segmentation techniques to individual consumer suitability for different distributed energy technologies.
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessSegmentation of household smart meter data linked to PV and battery value
The primary challenge with big smart meter data is to gain actionable insights which ultimately enhance the sustainability of the power network. In this paper, we analyze 1 year of smart meter data from 326 households in Austin, TX. Via clustering, we find distinct daily usage patterns, illustrating heterogeneous consumption behavior which changes throughout the year. However, most consumers have at least 56% of days explained by 3 out of 24 identified load types. For each load type we estimate the value of PV and batteries under flat rate and Time-Of-Use electricity tariffs. We find that knowledge of a consumers most common load shapes can significantly improve estimates for PV viability compared to a control estimate based on population-wide averages. However, knowledge of the most common load shapes does not improve estimates of battery viability unless electricity prices are time-varying. This highlights that, in general, the information contained by load shape clusters is of high value when consumers face economic choices that depend on the timing of their consumption. This work builds on current knowledge by explicitly linking smart meter segmentation techniques to individual consumer suitability for different distributed energy technologies.
- Open Access
Analysis of Smart Meter Electricity Consumption Data for PV Storage in the UK
Solar PV and battery energy storage (BES) costs for domestic consumers are constantly diminishing. On top of this, the end of the Feed-in-Tariff programme has significantly increased interest in combined PV + BES systems. In this paper, we explore the economics of domestic PV + BES systems, extending the current literature on the topic via the use of a large smart meter dataset and a demographic comparison. Predictably, time-varying tariffs and higher electricity prices generally strengthen the economic arguments for PV + BES systems, however our consumption data yields a wide range of Net Present Values for different consumers. In terms of demographics, we find that batteries are more favourable for more affluent households due to their larger consumption levels, though profitability becomes more uniform if the batteries are tailored to individual households. This is an important point for policy, since it indicates that if PV + BES systems become widely profitable this is unlikely to help the financial situation of lower-income households.
Open AccessAnalysis of Smart Meter Electricity Consumption Data for PV Storage in the UK
Solar PV and battery energy storage (BES) costs for domestic consumers are constantly diminishing. On top of this, the end of the Feed-in-Tariff programme has significantly increased interest in combined PV + BES systems. In this paper, we explore the economics of domestic PV + BES systems, extending the current literature on the topic via the use of a large smart meter dataset and a demographic comparison. Predictably, time-varying tariffs and higher electricity prices generally strengthen the economic arguments for PV + BES systems, however our consumption data yields a wide range of Net Present Values for different consumers. In terms of demographics, we find that batteries are more favourable for more affluent households due to their larger consumption levels, though profitability becomes more uniform if the batteries are tailored to individual households. This is an important point for policy, since it indicates that if PV + BES systems become widely profitable this is unlikely to help the financial situation of lower-income households.
- Open Access
Why is adiabatic compressed air energy storage yet to become a viable energy storage option?
- Open Access
How Does the Electricity Demand Profile Impact the Attractiveness of PV-Coupled Battery Systems Combining Applications?
Energy storage is a key solution to supply renewable electricity on demand and in particular batteries are becoming attractive for consumers who install PV panels. In order to minimize their electricity bill and keep the grid stable, batteries can combine applications. The daily match between PV supply and the electricity load profile is often considered as a determinant for the attractiveness of residential PV-coupled battery systems, however, the previous literature has so far mainly focused on the annual energy balance. In this paper, we analyze the techno-economic impact of adding a battery system to a new PV system that would otherwise be installed on its own, for different residential electricity load profiles in Geneva (Switzerland) and Austin (U.S.) using lithium-ion batteries performing various consumer applications, namely PV self-consumption, demand load-shifting, avoidance of PV curtailment, and demand peak shaving, individually and jointly. We employ clustering of the household’s load profile (with 15-minute resolution) for households with low, medium, and high annual electricity consumption in the two locations using a 1:1:1 sizing ratio. Our results show that with this simple sizing rule-of-thumb, the shape of the load profile has a small impact on the net present value of batteries. Overall, our analysis suggests that the effect of the load profile is small and differs across locations, whereas the combination of applications significantly increases profitability while marginally decreasing the share of self-consumption. Moreover, without the combination of applications, batteries are far from being economically viable.
Open AccessHow Does the Electricity Demand Profile Impact the Attractiveness of PV-Coupled Battery Systems Combining Applications?
Energy storage is a key solution to supply renewable electricity on demand and in particular batteries are becoming attractive for consumers who install PV panels. In order to minimize their electricity bill and keep the grid stable, batteries can combine applications. The daily match between PV supply and the electricity load profile is often considered as a determinant for the attractiveness of residential PV-coupled battery systems, however, the previous literature has so far mainly focused on the annual energy balance. In this paper, we analyze the techno-economic impact of adding a battery system to a new PV system that would otherwise be installed on its own, for different residential electricity load profiles in Geneva (Switzerland) and Austin (U.S.) using lithium-ion batteries performing various consumer applications, namely PV self-consumption, demand load-shifting, avoidance of PV curtailment, and demand peak shaving, individually and jointly. We employ clustering of the household’s load profile (with 15-minute resolution) for households with low, medium, and high annual electricity consumption in the two locations using a 1:1:1 sizing ratio. Our results show that with this simple sizing rule-of-thumb, the shape of the load profile has a small impact on the net present value of batteries. Overall, our analysis suggests that the effect of the load profile is small and differs across locations, whereas the combination of applications significantly increases profitability while marginally decreasing the share of self-consumption. Moreover, without the combination of applications, batteries are far from being economically viable.
- 1 September 2019
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 112, 978-990
Optimized PV-coupled battery systems for combining applications: Impact of battery technology and geography
- 1 September 2019
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 112, 978-990
Optimized PV-coupled battery systems for combining applications: Impact of battery technology and geography