Bruno Cardenas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bruno Cardenas has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Seamus D. Garvey
University of Nottingham
7 shared publications Seamus Garvey
5 shared publicationsZahra Baniamerian
Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham, United Kingdom
5 shared publications- Daniel Pottie
Centre for Renewable Energy Systems Technology Loughborough University Loughborough UK
4 shared publications - Edward Barbour
Centre for Renewable Energy Systems Technology Loughborough University Loughborough UK
4 shared publications - James Paul Rouse
Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham, Nottingham NG7 2RD, UK
4 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3185 (1)
Magnetite as a Heat Storage Medium in Packed Beds
The design and optimisation of a non-pressurised packed bed for a 10MW wind-driven CAES system is presented. The packed bed stores 80 MWh of heat in a temperature bracket between ambient and 340°C. The packed bed uses magnetite, an iron ore with a 60% higher volumetric energy density compared to more commonly used materials such as basalt rocks or quartzite. The effect that the aspect ratio, particle size and mass over-rating factor have on the performance of the unit is explored. Different forms of exergy loss are considered, including heat transfer exergy losses, self-discharge, exhaust losses and exergy losses due to pressure drops. Overall roundtrip exergy efficiencies >95% are achievable; however, heat losses to ambient are neglected. A techno-economic comparison against designs based on basalt rocks is presented.
- 1 February 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3185 (1)
Open AccessMagnetite as a Heat Storage Medium in Packed Beds
The design and optimisation of a non-pressurised packed bed for a 10MW wind-driven CAES system is presented. The packed bed stores 80 MWh of heat in a temperature bracket between ambient and 340°C. The packed bed uses magnetite, an iron ore with a 60% higher volumetric energy density compared to more commonly used materials such as basalt rocks or quartzite. The effect that the aspect ratio, particle size and mass over-rating factor have on the performance of the unit is explored. Different forms of exergy loss are considered, including heat transfer exergy losses, self-discharge, exhaust losses and exergy losses due to pressure drops. Overall roundtrip exergy efficiencies >95% are achievable; however, heat losses to ambient are neglected. A techno-economic comparison against designs based on basalt rocks is presented.
- Open Access
High-Performance Heat-Powered Heat Pumps
This paper introduces a zero-carbon heating solution called High-Performance Heat-Powered Heat Pumps (HP3), which combine the best attributes of hydrogen boilers and electric heat pumps. HP3 systems allow us to continue using the existing gas infrastructure, offer higher efficiencies than hydrogen boilers, and avoid overwhelming the electricity grid. An HP3 blends a heat engine and a heat pump into a single, fully integrated system sharing a common working fluid. This differentiates HP3 systems from gas-engine-driven heat pumps (GEHP), where the integration between subsystems is limited to a mechanical shaft. A parametric analysis of a propane-based system is presented. The heat engine section has two main design variables: the working fluid’s temperature () and pressure () after collecting high-grade heat from hydrogen combustion. Typical GEHPs achieve CoPs of around 1.8. The HP3 concept achieves a CoP of 2.59 considering a of 650 °C, of 250 bar, and an ambient temperature of −9 °C. The paper presents a model for the expander’s efficiency, which indicates that increasing the system’s output makes it possible to achieve a higher expansion efficiency with a lower rotational speed. Results show that HP3 is a promising concept for larger applications such as commercial buildings or district heating systems.Open AccessHigh-Performance Heat-Powered Heat Pumps
This paper introduces a zero-carbon heating solution called High-Performance Heat-Powered Heat Pumps (HP3), which combine the best attributes of hydrogen boilers and electric heat pumps. HP3 systems allow us to continue using the existing gas infrastructure, offer higher efficiencies than hydrogen boilers, and avoid overwhelming the electricity grid. An HP3 blends a heat engine and a heat pump into a single, fully integrated system sharing a common working fluid. This differentiates HP3 systems from gas-engine-driven heat pumps (GEHP), where the integration between subsystems is limited to a mechanical shaft. A parametric analysis of a propane-based system is presented. The heat engine section has two main design variables: the working fluid’s temperature () and pressure () after collecting high-grade heat from hydrogen combustion. Typical GEHPs achieve CoPs of around 1.8. The HP3 concept achieves a CoP of 2.59 considering a of 650 °C, of 250 bar, and an ambient temperature of −9 °C. The paper presents a model for the expander’s efficiency, which indicates that increasing the system’s output makes it possible to achieve a higher expansion efficiency with a lower rotational speed. Results show that HP3 is a promising concept for larger applications such as commercial buildings or district heating systems. - Open Access
How Heat-Powered Heat Pumps Could Reduce the Need for Grid-Scale Energy Storage
This paper explores how the deployment of “High-Performance Heat-Powered Heat Pumps” (HP3s)—a novel heating technology—could help meet the domestic heating demand in the UK and reduce how much grid-scale energy storage is needed in comparison to a scenario where electrical heat pumps fully supply the heating demand. HP3 systems can produce electricity, which can partially alleviate the stress caused by electrical heat pumps. A parametric analysis focusing on two variables, the penetration of HP3 systems (H) and the amount of electricity exported (Ɛ), is presented. For every combination of H and Ɛ, the electricity system is optimized to minimize the cost of electricity. Three parameters define the electricity system: the generation mix, the energy storage mix and the amount of over-generation. The cost of electricity is at its highest when electrical heat pumps supply all demand. This reduces as the penetration of HP3 systems increases due to a reduction in the need for energy storage. When HP3 systems supply 100% of the heating demand, the total cost of electricity and the storage capacity needed are 6% and 50% lower, respectively, compared to a scenario where electrical heat pumps are in 100% of residences.
Open AccessHow Heat-Powered Heat Pumps Could Reduce the Need for Grid-Scale Energy Storage
This paper explores how the deployment of “High-Performance Heat-Powered Heat Pumps” (HP3s)—a novel heating technology—could help meet the domestic heating demand in the UK and reduce how much grid-scale energy storage is needed in comparison to a scenario where electrical heat pumps fully supply the heating demand. HP3 systems can produce electricity, which can partially alleviate the stress caused by electrical heat pumps. A parametric analysis focusing on two variables, the penetration of HP3 systems (H) and the amount of electricity exported (Ɛ), is presented. For every combination of H and Ɛ, the electricity system is optimized to minimize the cost of electricity. Three parameters define the electricity system: the generation mix, the energy storage mix and the amount of over-generation. The cost of electricity is at its highest when electrical heat pumps supply all demand. This reduces as the penetration of HP3 systems increases due to a reduction in the need for energy storage. When HP3 systems supply 100% of the heating demand, the total cost of electricity and the storage capacity needed are 6% and 50% lower, respectively, compared to a scenario where electrical heat pumps are in 100% of residences.
- Open Access
- 22 September 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 177
The physical exergy in hydrogen – maximising the utility of hydrogen as an aviation fuel
- 22 September 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 177
Open AccessThe physical exergy in hydrogen – maximising the utility of hydrogen as an aviation fuel
- Open Access
- 4 April 2025
- Published by Elsevier in Renewable Energy
- Vol. 247
Heat pumps’ impact on the requirement for grid-scale energy storage in the UK
- 4 April 2025
- Published by Elsevier in Renewable Energy
- Vol. 247
Open AccessHeat pumps’ impact on the requirement for grid-scale energy storage in the UK
- Open Access
- 22 February 2025
- Published by Elsevier in Technology in Society
- Vol. 81
Feeling the heat: Understanding stakeholders’ perceptions of residential-sector heating decarbonisation options in the UK
- 22 February 2025
- Published by Elsevier in Technology in Society
- Vol. 81
Open AccessFeeling the heat: Understanding stakeholders’ perceptions of residential-sector heating decarbonisation options in the UK
- Open Access
- 3 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Exergy analysis of isochoric and isobaric adiabatic compressed air energy storage
Adiabatic compressed air energy storage (ACAES) is an energy storage technology that has the potential to play an important role in the transition to a predominantly renewables‐driven net‐zero energy system. However, it has not yet achieved the performance necessary to be widely deployed. This paper undertakes an exergy analysis of isobaric and isochoric ACAES systems, tracking lost work through the components and exploring the influences of different design choices. Three different configurations are modelled: (1) 3 compression and 3 expansion stages; (2) 4 compression and 2 expansion stages; and (3) 2 compression and 4 expansion stages. These results illustrate that isobaric systems are likely to have higher round‐trip efficiency and significantly higher energy density, at the cost of achieving isobaric storage. Exergy analysis reveals that most of the losses arise in the compressors, compressor aftercoolers and expanders. Losses in aftercoolers are exaggerated when compressors operate with high‐pressure ratios, emphasizing that the choice of TES is a key system variable. With pressurised water as the coolant and TES fluid, it seems likely that the best system will have more compression than expansion stages. Increasing the number of compression stages decreases the off‐design penalty when the system is isochoric.
- 3 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessExergy analysis of isochoric and isobaric adiabatic compressed air energy storage
Adiabatic compressed air energy storage (ACAES) is an energy storage technology that has the potential to play an important role in the transition to a predominantly renewables‐driven net‐zero energy system. However, it has not yet achieved the performance necessary to be widely deployed. This paper undertakes an exergy analysis of isobaric and isochoric ACAES systems, tracking lost work through the components and exploring the influences of different design choices. Three different configurations are modelled: (1) 3 compression and 3 expansion stages; (2) 4 compression and 2 expansion stages; and (3) 2 compression and 4 expansion stages. These results illustrate that isobaric systems are likely to have higher round‐trip efficiency and significantly higher energy density, at the cost of achieving isobaric storage. Exergy analysis reveals that most of the losses arise in the compressors, compressor aftercoolers and expanders. Losses in aftercoolers are exaggerated when compressors operate with high‐pressure ratios, emphasizing that the choice of TES is a key system variable. With pressurised water as the coolant and TES fluid, it seems likely that the best system will have more compression than expansion stages. Increasing the number of compression stages decreases the off‐design penalty when the system is isochoric.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Design of a Combined Heat Store and Heat Exchanger for CAES Systems
A combined heat store and heat exchanger unit (HSX) intended for compressed air energy storage (CAES) is presented. The unit is directly charged by the pressurised air emerging from the compression train, which removes the need for a secondary low‐pressure air circuit. Salt is used as the thermal storage medium due to its good heat capacity, thermal conductivity, and its ability to accommodate the thermal expansion of the stainless‐steel pipes. This paper uses a CAES system (15 MW, 12‐h discharge) driven by an offshore wind turbine as a case study. There are not many commercial CAES systems in operation; however, the levelized cost of the heat storage subsystem of a CAES system (i.e. heat store, set of heat exchangers and ancillary low‐pressure circuit) ranges between 45 and 48 £/MWh. Findings show that the most cost‐effective design for a HSX has a capital cost of ∼£55k. This translates into a levelized cost of storage of ∼31.5 £/MWh. The roundtrip exergy efficiency of this design is 93.7 %. This accounts for heat‐exergy and pressure‐exergy losses; losses to ambient are not considered. A HSX unit can considerably reduce the overall cost of a CAES system.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessDesign of a Combined Heat Store and Heat Exchanger for CAES Systems
A combined heat store and heat exchanger unit (HSX) intended for compressed air energy storage (CAES) is presented. The unit is directly charged by the pressurised air emerging from the compression train, which removes the need for a secondary low‐pressure air circuit. Salt is used as the thermal storage medium due to its good heat capacity, thermal conductivity, and its ability to accommodate the thermal expansion of the stainless‐steel pipes. This paper uses a CAES system (15 MW, 12‐h discharge) driven by an offshore wind turbine as a case study. There are not many commercial CAES systems in operation; however, the levelized cost of the heat storage subsystem of a CAES system (i.e. heat store, set of heat exchangers and ancillary low‐pressure circuit) ranges between 45 and 48 £/MWh. Findings show that the most cost‐effective design for a HSX has a capital cost of ∼£55k. This translates into a levelized cost of storage of ∼31.5 £/MWh. The roundtrip exergy efficiency of this design is 93.7 %. This accounts for heat‐exergy and pressure‐exergy losses; losses to ambient are not considered. A HSX unit can considerably reduce the overall cost of a CAES system.
- Open Access
- 27 February 2024
- Published by Elsevier in Energy Conversion and Management
- Vol. 304
Adiabatic Compressed Air Energy Storage system performance with application-oriented designed axial-flow compressor
- 27 February 2024
- Published by Elsevier in Energy Conversion and Management
- Vol. 304
Open AccessAdiabatic Compressed Air Energy Storage system performance with application-oriented designed axial-flow compressor