Shaoyang Dai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shaoyang Dai has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Fang Fang
Division of Time and Frequency Metrology, National Institute of Metrology (NIM), Beijing, China
6 shared publications- Fasong Zheng
Division of Time and Frequency Metrology, National Institute of Metrology (NIM), Beijing, China
4 shared publications - Kun Liu
National Institute of Metrology
4 shared publications Weiliang Chen
National Institute of Metrology (NIM), Beijing 100029, People’s Republic of China
4 shared publications- Yani Zuo
Division of Time and Frequency Metrology, National Institute of Metrology (NIM), Beijing, China
3 shared publications - Chaowei Wang
Department of Precision Machinery and Precision Instruments, School of Engineering Science, University of Science and Technology of China 3 , Hefei, Anhui 230022
2 shared publications
Latest Publications
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
A Multistanding-Wave Field Microwave Cavity for Compact Cold-Atom Ramsey Clocks
Compact cold-atom frequency standards, characterized by low frequency drift and high accuracy, continue to attract significant interest to address the growing demand for portable, high-performance time-keeping solutions. This paper presents and experimentally demonstrates a proof-of-principle prototype of a compact cold-atom Ramsey clock. The system is based on a multi-standing-wave field microwave cavity operating in the TE₀₁₃ mode and employs a free-falling atom scheme to simplify optical frequency control. The chosen TE₀₁₃ cavity is a cylindrical microwave resonator (CMR) fabricated from oxygen-free copper (OFC), which offers advantages in size and microwave leakage control over the conventional TE₀₁₁ cavity for this free-fall configuration. Its structure, which also serves as the vacuum chamber, is sealed with ceramic windows and coupled via rectangular waveguides. During operation, atoms interact with the first and third standing-wave fields to implement Ramsey interrogation. Experimental results show optimal pulse timing with τ1=16 ms, which aligns closely with theoretical predictions (τ1=16.1 ms). The measured central Ramsey fringe has a full width at half maximum (FWHM) of 8.9 Hz and a contrast of 89.1%, corresponding to a measured relative frequency instability of 6.4×10−13 τ-1/2.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
A Multistanding-Wave Field Microwave Cavity for Compact Cold-Atom Ramsey Clocks
Compact cold-atom frequency standards, characterized by low frequency drift and high accuracy, continue to attract significant interest to address the growing demand for portable, high-performance time-keeping solutions. This paper presents and experimentally demonstrates a proof-of-principle prototype of a compact cold-atom Ramsey clock. The system is based on a multi-standing-wave field microwave cavity operating in the TE₀₁₃ mode and employs a free-falling atom scheme to simplify optical frequency control. The chosen TE₀₁₃ cavity is a cylindrical microwave resonator (CMR) fabricated from oxygen-free copper (OFC), which offers advantages in size and microwave leakage control over the conventional TE₀₁₁ cavity for this free-fall configuration. Its structure, which also serves as the vacuum chamber, is sealed with ceramic windows and coupled via rectangular waveguides. During operation, atoms interact with the first and third standing-wave fields to implement Ramsey interrogation. Experimental results show optimal pulse timing with τ1=16 ms, which aligns closely with theoretical predictions (τ1=16.1 ms). The measured central Ramsey fringe has a full width at half maximum (FWHM) of 8.9 Hz and a contrast of 89.1%, corresponding to a measured relative frequency instability of 6.4×10−13 τ-1/2.
- Open Access
- 6 March 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (2) , 029501
CORRIGENDUM: Uncertainty evaluation of the caesium fountain primary frequency standard NIM6 (2025 Metrologia 62 035005)
- 6 March 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (2) , 029501
Open AccessCORRIGENDUM: Uncertainty evaluation of the caesium fountain primary frequency standard NIM6 (2025 Metrologia 62 035005)
- Open Access
- 1 July 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (7)
The research of 369.5 nm laser stabilizing method and its influence on ytterbium ion optical clock
The 369.5 nm laser serves as the cooling laser for ytterbium-ion optical clocks, and its frequency instability directly affects the intensity of ion fluorescence. This paper compares two stabilization methods for a 369.5 nm frequency-tripled fiber laser: locking to a femtosecond optical frequency comb (FOFC) and locking to a wavelength meter. The FOFC-locked laser achieves a frequency instability of 2.85 × 10−13 at 1 s, three orders of magnitude lower than that of the wavelength meter-locked laser. Fluorescence variations from a single Yb+ ion are monitored under both locking schemes; the FOFC lock produces less than half the fluorescence fluctuation observed with the wavelength meter lock, thereby improving the signal-to-noise ratio. The reduced fluorescence noise lowers the quantum projection noise of the Yb+ optical clock, enabling the attainment of lower overall clock instability.
- 1 July 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (7)
Open AccessThe research of 369.5 nm laser stabilizing method and its influence on ytterbium ion optical clock
The 369.5 nm laser serves as the cooling laser for ytterbium-ion optical clocks, and its frequency instability directly affects the intensity of ion fluorescence. This paper compares two stabilization methods for a 369.5 nm frequency-tripled fiber laser: locking to a femtosecond optical frequency comb (FOFC) and locking to a wavelength meter. The FOFC-locked laser achieves a frequency instability of 2.85 × 10−13 at 1 s, three orders of magnitude lower than that of the wavelength meter-locked laser. Fluorescence variations from a single Yb+ ion are monitored under both locking schemes; the FOFC lock produces less than half the fluorescence fluctuation observed with the wavelength meter lock, thereby improving the signal-to-noise ratio. The reduced fluorescence noise lowers the quantum projection noise of the Yb+ optical clock, enabling the attainment of lower overall clock instability.
- Open Access
- 27 May 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (3) , 035005
Uncertainty evaluation of the caesium fountain primary frequency standard NIM6
A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term fractional frequency instability of 1.0 × 10 −13 τ −1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.2 × 10 −16 . Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain primary frequency standards through Coordinated Universal Time have demonstrated an agreement within the stated uncertainties.
- 27 May 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (3) , 035005
Open AccessUncertainty evaluation of the caesium fountain primary frequency standard NIM6
A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term fractional frequency instability of 1.0 × 10 −13 τ −1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.2 × 10 −16 . Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain primary frequency standards through Coordinated Universal Time have demonstrated an agreement within the stated uncertainties.
- Open Access
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Design optimization and precision requirements of an endcap ion trap for single-ion optical clock applications
Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Open AccessDesign optimization and precision requirements of an endcap ion trap for single-ion optical clock applications
Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 054702
Design and operation of a transportable 87Rb atomic fountain clock
A transportable fountain clock with high reliability is important for high-precision time-frequency measurements. Because of its relatively small cold atoms’ collision frequency shift and ease of attaining high quantum state preparation efficiency, the rubidium atomic fountain clock has an indicated higher stability and reliability. This paper reports the design and operation of a transportable rubidium atomic fountain clock developed by the Shanghai Institute of Optical and Fine Mechanics, Chinese Academy of Science. After being transported more than 1000 km from Shanghai to the Changping Campus of the National Institute of Metrology, China, the optical platform and other hardware of the fountain clock did not need to be adjusted. The rubidium fountain clock maintained a stability of 4.0 × 10−13τ1/2, reaching 5.0 × 10−16 at 300 000 s. After transportation, the rubidium fountain clock and a cesium fountain clock (NIM5) were operated together against the reference frequency of a hydrogen maser. In three separate operating periods, over a total of nearly three months, the average frequency repeatability of the rubidium fountain was less than 3.8 × 10−15.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 054702
Design and operation of a transportable 87Rb atomic fountain clock
A transportable fountain clock with high reliability is important for high-precision time-frequency measurements. Because of its relatively small cold atoms’ collision frequency shift and ease of attaining high quantum state preparation efficiency, the rubidium atomic fountain clock has an indicated higher stability and reliability. This paper reports the design and operation of a transportable rubidium atomic fountain clock developed by the Shanghai Institute of Optical and Fine Mechanics, Chinese Academy of Science. After being transported more than 1000 km from Shanghai to the Changping Campus of the National Institute of Metrology, China, the optical platform and other hardware of the fountain clock did not need to be adjusted. The rubidium fountain clock maintained a stability of 4.0 × 10−13τ1/2, reaching 5.0 × 10−16 at 300 000 s. After transportation, the rubidium fountain clock and a cesium fountain clock (NIM5) were operated together against the reference frequency of a hydrogen maser. In three separate operating periods, over a total of nearly three months, the average frequency repeatability of the rubidium fountain was less than 3.8 × 10−15.
- Open Access
- 1 June 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (6) , 065118
The optically generated microwave oscillator with long-term stability locked at hydrogen maser
We present an oscillator of optically generated microwaves (OGMs) based on an optical frequency comb (OFC) and an ultrastable laser (USL). The USL provides short-term stability, and the OFC transfers the short-term stability to radio frequencies. Frequency synthesis is used to transfer the stability of the OGM oscillator to an oven-controlled crystal oscillator (OCXO). To improve the long-term stability of the OCXO, an additional compensating loop was applied to lock the long term stability of OGM at a hydrogen maser by compensating the frequency drift of the USL. The phase noise of the OCXO is maintained sufficiently low through these locked loops. The OCXO’s phase noise at 1 Hz is about −116 dBc/Hz. The short-term stability (1–100 s) of the OCXO with different compensating periods is better than 4 × 10−15. By replacing the H-maser (BIPM code: 1404850) with the OGM as the local oscillator, the stability of the NIM6 Cs fountain clock is improved from (1.2 × 10−13)τ−1/2 to (5.1 × 10−14)τ−1/2. This work should help optimize fountain clocks for better type A uncertainty or faster frequency offset evaluations.
- 1 June 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (6) , 065118
Open AccessThe optically generated microwave oscillator with long-term stability locked at hydrogen maser
We present an oscillator of optically generated microwaves (OGMs) based on an optical frequency comb (OFC) and an ultrastable laser (USL). The USL provides short-term stability, and the OFC transfers the short-term stability to radio frequencies. Frequency synthesis is used to transfer the stability of the OGM oscillator to an oven-controlled crystal oscillator (OCXO). To improve the long-term stability of the OCXO, an additional compensating loop was applied to lock the long term stability of OGM at a hydrogen maser by compensating the frequency drift of the USL. The phase noise of the OCXO is maintained sufficiently low through these locked loops. The OCXO’s phase noise at 1 Hz is about −116 dBc/Hz. The short-term stability (1–100 s) of the OCXO with different compensating periods is better than 4 × 10−15. By replacing the H-maser (BIPM code: 1404850) with the OGM as the local oscillator, the stability of the NIM6 Cs fountain clock is improved from (1.2 × 10−13)τ−1/2 to (5.1 × 10−14)τ−1/2. This work should help optimize fountain clocks for better type A uncertainty or faster frequency offset evaluations.
- 1 November 2016
- Published by Elsevier in Optics Communications
- Vol. 378, 35-40
Polarization dependence of the direct two photon transitions of 87Rb atoms by erbium: Fiber laser frequency comb
- 1 November 2016
- Published by Elsevier in Optics Communications
- Vol. 378, 35-40
Polarization dependence of the direct two photon transitions of 87Rb atoms by erbium: Fiber laser frequency comb