Chaowei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chaowei Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Fang Fang
Time and Frequency Division, National Institute of Metrology 1 , Beijing 100029
2 shared publications- Shaoyang Dai
Division of Time and Frequency Metrology, National Institute of Metrology (NIM), Beijing, China
2 shared publications - Yani Zuo
Division of Time and Frequency Metrology, National Institute of Metrology (NIM), Beijing, China
2 shared publications - Fasong Zheng
Division of Time and Frequency Metrology, National Institute of Metrology (NIM), Beijing, China
1 shared publication - Kun Liu
National Institute of Metrology
1 shared publication Shiying Cao
Time and Frequency Division, National Institute of Metrology 1 , Beijing 100029
1 shared publication
Latest Publications
- Open Access
- 1 July 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (7)
The research of 369.5 nm laser stabilizing method and its influence on ytterbium ion optical clock
The 369.5 nm laser serves as the cooling laser for ytterbium-ion optical clocks, and its frequency instability directly affects the intensity of ion fluorescence. This paper compares two stabilization methods for a 369.5 nm frequency-tripled fiber laser: locking to a femtosecond optical frequency comb (FOFC) and locking to a wavelength meter. The FOFC-locked laser achieves a frequency instability of 2.85 × 10−13 at 1 s, three orders of magnitude lower than that of the wavelength meter-locked laser. Fluorescence variations from a single Yb+ ion are monitored under both locking schemes; the FOFC lock produces less than half the fluorescence fluctuation observed with the wavelength meter lock, thereby improving the signal-to-noise ratio. The reduced fluorescence noise lowers the quantum projection noise of the Yb+ optical clock, enabling the attainment of lower overall clock instability.
- 1 July 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (7)
Open AccessThe research of 369.5 nm laser stabilizing method and its influence on ytterbium ion optical clock
The 369.5 nm laser serves as the cooling laser for ytterbium-ion optical clocks, and its frequency instability directly affects the intensity of ion fluorescence. This paper compares two stabilization methods for a 369.5 nm frequency-tripled fiber laser: locking to a femtosecond optical frequency comb (FOFC) and locking to a wavelength meter. The FOFC-locked laser achieves a frequency instability of 2.85 × 10−13 at 1 s, three orders of magnitude lower than that of the wavelength meter-locked laser. Fluorescence variations from a single Yb+ ion are monitored under both locking schemes; the FOFC lock produces less than half the fluorescence fluctuation observed with the wavelength meter lock, thereby improving the signal-to-noise ratio. The reduced fluorescence noise lowers the quantum projection noise of the Yb+ optical clock, enabling the attainment of lower overall clock instability.
- Open Access
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Design optimization and precision requirements of an endcap ion trap for single-ion optical clock applications
Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Open AccessDesign optimization and precision requirements of an endcap ion trap for single-ion optical clock applications
Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.