Natsumi Kimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Natsumi Kimoto has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Hayashi
College of Transdisciplinary Sciences for Innovation Kanazawa University Kanazawa Ishikawa Japan
15 shared publications - Takashi Asahara
Department of Radiological Technology, Faculty of Health Sciences Okayama University Okayama Japan
10 shared publications - Yuki Kanazawa
Department of Medical Imaging Physics, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Chuo-Ku, Kumamoto, 862-0976, Japan.
6 shared publications - Rina Nishigami5 shared publications
Daiki Kobayashi
4 shared publications- Shuichiro Yamamoto
JOB CORPORATION, Kanagawa, 222-0033, Japan
4 shared publications
Latest Publications
- Open Access
- 7 November 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (3)
A simple and practical correction procedure for non-uniformity in quantitative X-ray images generated with an energy-resolving photon-counting detector
- 7 November 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (3)
Open AccessA simple and practical correction procedure for non-uniformity in quantitative X-ray images generated with an energy-resolving photon-counting detector
- Open Access
- 19 September 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 251
A rule-based calculation approach to derive bone-suppressed chest X-ray images using photon-counting techniques
- 19 September 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 251
Open AccessA rule-based calculation approach to derive bone-suppressed chest X-ray images using photon-counting techniques
- Open Access
- 1 September 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (1)
Impact of correcting beam hardening and detector response function in photon-counting X-ray imaging when using anti-coincidence mode
- 1 September 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (1)
Open AccessImpact of correcting beam hardening and detector response function in photon-counting X-ray imaging when using anti-coincidence mode
- Open Access
- 23 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112768
An algorithm to calculate physical density of biomedical objects having 3 ≤ Zeff ≤ 20: an application study using clinical photon-counting computed tomography equipment
- 23 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112768
Open AccessAn algorithm to calculate physical density of biomedical objects having 3 ≤ Zeff ≤ 20: an application study using clinical photon-counting computed tomography equipment
- Open Access
- 26 February 2026
- Published by Elsevier in SSRN Electronic Journal
Development of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for patients and clinical staff. The aim of this study is to develop a compact active-type dosimeter based on an optically stimulated luminescence (OSL) system, and to establish a dose measurement procedure for diagnostic X-rays. The proposed dosimeter consists of an OSL sheet made of Al2O3:C and a multi-pixel photon counter (MPPC), and the detector region dimension is 10 mm × 10 mm × 13 mm. List-mode datasets consisting of measurement time and pulse height were recorded. The accumulated signal was analyzed by integrating the pulse-height data, in which the processing for smoothing, recovery-time correction, and counting-loss correction were performed. A dose calibration curve was determined from the integrated signal and reference air kerma measured with an ionization chamber. System performance was evaluated using diagnostic X-ray equipment under various dose rate conditions: a tube voltage of 80 kV, tube currents of 20–160 mA, and an exposure time of 1.0 s. Clinical applicability was also verified under typical exposure conditions for hand (50 kV), abdominal (80 kV), and chest (120 kV) examinations. In the experimental results, it was found that the proposed dosimeter can appropriately measure list-mode datasets and determine the accumulated dose with an accuracy of ±20% for 0.3–10 mGy/s. These findings indicate that the proposed dosimeter can be used for clinical dosimetry during diagnostic X-ray examinations.
- 26 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for patients and clinical staff. The aim of this study is to develop a compact active-type dosimeter based on an optically stimulated luminescence (OSL) system, and to establish a dose measurement procedure for diagnostic X-rays. The proposed dosimeter consists of an OSL sheet made of Al2O3:C and a multi-pixel photon counter (MPPC), and the detector region dimension is 10 mm × 10 mm × 13 mm. List-mode datasets consisting of measurement time and pulse height were recorded. The accumulated signal was analyzed by integrating the pulse-height data, in which the processing for smoothing, recovery-time correction, and counting-loss correction were performed. A dose calibration curve was determined from the integrated signal and reference air kerma measured with an ionization chamber. System performance was evaluated using diagnostic X-ray equipment under various dose rate conditions: a tube voltage of 80 kV, tube currents of 20–160 mA, and an exposure time of 1.0 s. Clinical applicability was also verified under typical exposure conditions for hand (50 kV), abdominal (80 kV), and chest (120 kV) examinations. In the experimental results, it was found that the proposed dosimeter can appropriately measure list-mode datasets and determine the accumulated dose with an accuracy of ±20% for 0.3–10 mGy/s. These findings indicate that the proposed dosimeter can be used for clinical dosimetry during diagnostic X-ray examinations.
- Open Access
- 22 September 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 378-386
Applicability of Effective Atomic Number (Z eff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography
Objective: Coronary computed tomography (CT) allows the assessment of cardiovascular risk by imaging calcified plaques in coronary arteries. Because photon-counting CT (PC-CT) can analyze the effective atomic number (Z eff) of the subject, it is expected to be applied to the analysis of plaque components. The purpose of this study was to investigate the applicability of plaque analysis based on Z eff images with continuous gradation. Methods: Z eff images were generated from virtual monoenergetic images (VMIs) obtained by PC-CT. Z eff values were derived from the difference between linear attenuation coefficients (μ) at low and high energies using an in-house program. Coronary CT images of 64 plaques in 10 patients were analyzed. The Z eff score, calculated as the sum of Z eff values within the plaque region, was calculated and compared with the conventional Agatston score and mean coronary artery calcium (CAC) score. Results: The systematic uncertainty of Z eff images was estimated to be ±0.08. The Z eff score of actual patient data showed strong positive correlations with the conventional Agatston and mean CAC scores. The Z eff score uses all voxel data in the plaque area, whereas conventional scores consider only data from voxels with a CT value >130. We found that the conventional scores excluded 39% of the plaque area, and the Z eff score permitted the analysis of low- and high-density plaques. Conclusions: Z eff imaging was shown to be applicable to plaque analysis that reflects the entire plaque volume. This study demonstrated its technical feasibility as a compositional analysis method using the Z eff image.
- 22 September 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 378-386
Open AccessApplicability of Effective Atomic Number (Z eff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography
Objective: Coronary computed tomography (CT) allows the assessment of cardiovascular risk by imaging calcified plaques in coronary arteries. Because photon-counting CT (PC-CT) can analyze the effective atomic number (Z eff) of the subject, it is expected to be applied to the analysis of plaque components. The purpose of this study was to investigate the applicability of plaque analysis based on Z eff images with continuous gradation. Methods: Z eff images were generated from virtual monoenergetic images (VMIs) obtained by PC-CT. Z eff values were derived from the difference between linear attenuation coefficients (μ) at low and high energies using an in-house program. Coronary CT images of 64 plaques in 10 patients were analyzed. The Z eff score, calculated as the sum of Z eff values within the plaque region, was calculated and compared with the conventional Agatston score and mean coronary artery calcium (CAC) score. Results: The systematic uncertainty of Z eff images was estimated to be ±0.08. The Z eff score of actual patient data showed strong positive correlations with the conventional Agatston and mean CAC scores. The Z eff score uses all voxel data in the plaque area, whereas conventional scores consider only data from voxels with a CT value >130. We found that the conventional scores excluded 39% of the plaque area, and the Z eff score permitted the analysis of low- and high-density plaques. Conclusions: Z eff imaging was shown to be applicable to plaque analysis that reflects the entire plaque volume. This study demonstrated its technical feasibility as a compositional analysis method using the Z eff image.
- Open Access
- 20 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70007
Determination of appropriate energy threshold range for accurate estimation of effective atomic number considering statistical uncertainty in photon‐counting techniques
Purpose: The energy threshold is an important parameter for precise material identification employing photon‐counting techniques. However, in such applications, the appropriate energy threshold has not been clarified. Therefore, we aimed to determine the appropriate energy threshold range for precise material identification, focusing on effective atomic number (Z) values as an index.Methods: The atomic number was estimated using a previously proposed algorithm and Monte Carlo simulations. This algorithm included three steps: calculating the attenuation factor from the incident photon counts on a photon‐counting detector, correcting the beam‐hardening effects, and estimating the atomic number from the attenuation factor index using the calibration curve. Monte Carlo simulations were performed to add Poisson noise to an ideal x‐ray spectrum. The total number of incident x‐rays was set in the range of 103–106. The x‐ray spectra were generated at tube voltages of 50–120 kV. Polymethyl methacrylate (Z = 6.5) and aluminum (Z = 13) were used for the analysis. The energy threshold was varied at intervals of 1 keV to estimate the atomic number. We evaluated the appropriate energy threshold range for accurately estimating the atomic number using the obtained atomic number data and statistical uncertainty under various conditions.Results: The appropriate energy threshold range was found to be 31–38 keV for a tube voltage range of 50–120 kV. At this energy threshold, the atomic number can be estimated within an accuracy of ± 0.7 at 105 counts for the atomic number range of 6.5 (PMMA) to 13 (Al).Conclusions: We found the appropriate energy threshold range. The findings of this study are expected to be useful for appropriately setting the energy threshold during precise material identification using photon‐counting detectors for clinical applications.
- 20 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70007
Open AccessDetermination of appropriate energy threshold range for accurate estimation of effective atomic number considering statistical uncertainty in photon‐counting techniques
Purpose: The energy threshold is an important parameter for precise material identification employing photon‐counting techniques. However, in such applications, the appropriate energy threshold has not been clarified. Therefore, we aimed to determine the appropriate energy threshold range for precise material identification, focusing on effective atomic number (Z) values as an index.Methods: The atomic number was estimated using a previously proposed algorithm and Monte Carlo simulations. This algorithm included three steps: calculating the attenuation factor from the incident photon counts on a photon‐counting detector, correcting the beam‐hardening effects, and estimating the atomic number from the attenuation factor index using the calibration curve. Monte Carlo simulations were performed to add Poisson noise to an ideal x‐ray spectrum. The total number of incident x‐rays was set in the range of 103–106. The x‐ray spectra were generated at tube voltages of 50–120 kV. Polymethyl methacrylate (Z = 6.5) and aluminum (Z = 13) were used for the analysis. The energy threshold was varied at intervals of 1 keV to estimate the atomic number. We evaluated the appropriate energy threshold range for accurately estimating the atomic number using the obtained atomic number data and statistical uncertainty under various conditions.Results: The appropriate energy threshold range was found to be 31–38 keV for a tube voltage range of 50–120 kV. At this energy threshold, the atomic number can be estimated within an accuracy of ± 0.7 at 105 counts for the atomic number range of 6.5 (PMMA) to 13 (Al).Conclusions: We found the appropriate energy threshold range. The findings of this study are expected to be useful for appropriately setting the energy threshold during precise material identification using photon‐counting detectors for clinical applications.
- 26 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075023
A blurring correction method suitable to analyze quantitative x-ray images derived from energy-resolving photon counting detector
Objective. The purpose of this study is to propose a novel blurring correction method that enables accurate quantitative analysis of the object edge when using energy-resolving photon counting detectors (ERPCDs). Although the ERPCDs have the ability to generate various quantitative analysis techniques, such as the derivations of effective atomic number ( Z eff ) and bone mineral density values, at the object edge in these quantitative images, accurate quantitative information cannot be obtained. This is because image blurring prevents the gathering of accurate primary x-ray attenuation information. Approach. We developed the following procedure for blurring correction. A 5 × 5 pixels masking region was set as the processing area, and the pixels affected by blurring were extracted from the analysis of pixel value distribution. The blurred pixel values were then corrected to the proper values estimated by analyzing minimum and/or maximum values in the set mask area. The suitability of our correction method was verified by a simulation study and an experiment using a prototype ERPCD. Main results . When Z eff image of aluminum objects ( Z eff = 13) were analyzed without applying our correction method, regardless of raw data or correction data applying a conventional edge enhancement method, the proper Z eff values could not be derived for the object edge. In contrast, when applying our correction method, 82% of pixels affected by blurring were corrected and the proper Z eff values were calculated for those pixels. As a result of investigating the applicability limits of our method through simulation, it was proven that it works effectively for objects with 4 × 4 pixels or more. Significance . Our method is effective in correcting image blurring when the quantitative image is calculated based on multiple images. It will become an in-demand technology for putting a quantitative diagnosis into actual medical examinations.
- 26 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075023
A blurring correction method suitable to analyze quantitative x-ray images derived from energy-resolving photon counting detector
Objective. The purpose of this study is to propose a novel blurring correction method that enables accurate quantitative analysis of the object edge when using energy-resolving photon counting detectors (ERPCDs). Although the ERPCDs have the ability to generate various quantitative analysis techniques, such as the derivations of effective atomic number ( Z eff ) and bone mineral density values, at the object edge in these quantitative images, accurate quantitative information cannot be obtained. This is because image blurring prevents the gathering of accurate primary x-ray attenuation information. Approach. We developed the following procedure for blurring correction. A 5 × 5 pixels masking region was set as the processing area, and the pixels affected by blurring were extracted from the analysis of pixel value distribution. The blurred pixel values were then corrected to the proper values estimated by analyzing minimum and/or maximum values in the set mask area. The suitability of our correction method was verified by a simulation study and an experiment using a prototype ERPCD. Main results . When Z eff image of aluminum objects ( Z eff = 13) were analyzed without applying our correction method, regardless of raw data or correction data applying a conventional edge enhancement method, the proper Z eff values could not be derived for the object edge. In contrast, when applying our correction method, 82% of pixels affected by blurring were corrected and the proper Z eff values were calculated for those pixels. As a result of investigating the applicability limits of our method through simulation, it was proven that it works effectively for objects with 4 × 4 pixels or more. Significance . Our method is effective in correcting image blurring when the quantitative image is calculated based on multiple images. It will become an in-demand technology for putting a quantitative diagnosis into actual medical examinations.
- 3 March 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 195
Experimental study of X-ray dose reduction factor when using various size bismuth and lead particles
- 3 March 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 195
Experimental study of X-ray dose reduction factor when using various size bismuth and lead particles