Rina Nishigami
Research Subjects
Rina Nishigami has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Hayashi
College of Transdisciplinary Sciences for Innovation Kanazawa University Kanazawa Ishikawa Japan
6 shared publications - Takashi Asahara
Department of Radiological Technology, Faculty of Health Sciences Okayama University Okayama Japan
6 shared publications Daiki Kobayashi
5 shared publications- Natsumi Kimoto
Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, 1-1-1 Chikushigaoka, Fukuoka, Minami-Ku, 815-8510, Japan
5 shared publications - Mana Mitani3 shared publications
- Takuya Kasue3 shared publications
Latest Publications
- Open Access
- 7 November 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (3)
A simple and practical correction procedure for non-uniformity in quantitative X-ray images generated with an energy-resolving photon-counting detector
- 7 November 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (3)
Open AccessA simple and practical correction procedure for non-uniformity in quantitative X-ray images generated with an energy-resolving photon-counting detector
- Open Access
- 19 September 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 251
A rule-based calculation approach to derive bone-suppressed chest X-ray images using photon-counting techniques
- 19 September 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 251
Open AccessA rule-based calculation approach to derive bone-suppressed chest X-ray images using photon-counting techniques
- Open Access
- 1 September 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (1)
Impact of correcting beam hardening and detector response function in photon-counting X-ray imaging when using anti-coincidence mode
- 1 September 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (1)
Open AccessImpact of correcting beam hardening and detector response function in photon-counting X-ray imaging when using anti-coincidence mode
- Open Access
- 26 February 2026
- Published by Elsevier in SSRN Electronic Journal
Development of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for patients and clinical staff. The aim of this study is to develop a compact active-type dosimeter based on an optically stimulated luminescence (OSL) system, and to establish a dose measurement procedure for diagnostic X-rays. The proposed dosimeter consists of an OSL sheet made of Al2O3:C and a multi-pixel photon counter (MPPC), and the detector region dimension is 10 mm × 10 mm × 13 mm. List-mode datasets consisting of measurement time and pulse height were recorded. The accumulated signal was analyzed by integrating the pulse-height data, in which the processing for smoothing, recovery-time correction, and counting-loss correction were performed. A dose calibration curve was determined from the integrated signal and reference air kerma measured with an ionization chamber. System performance was evaluated using diagnostic X-ray equipment under various dose rate conditions: a tube voltage of 80 kV, tube currents of 20–160 mA, and an exposure time of 1.0 s. Clinical applicability was also verified under typical exposure conditions for hand (50 kV), abdominal (80 kV), and chest (120 kV) examinations. In the experimental results, it was found that the proposed dosimeter can appropriately measure list-mode datasets and determine the accumulated dose with an accuracy of ±20% for 0.3–10 mGy/s. These findings indicate that the proposed dosimeter can be used for clinical dosimetry during diagnostic X-ray examinations.
- 26 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for patients and clinical staff. The aim of this study is to develop a compact active-type dosimeter based on an optically stimulated luminescence (OSL) system, and to establish a dose measurement procedure for diagnostic X-rays. The proposed dosimeter consists of an OSL sheet made of Al2O3:C and a multi-pixel photon counter (MPPC), and the detector region dimension is 10 mm × 10 mm × 13 mm. List-mode datasets consisting of measurement time and pulse height were recorded. The accumulated signal was analyzed by integrating the pulse-height data, in which the processing for smoothing, recovery-time correction, and counting-loss correction were performed. A dose calibration curve was determined from the integrated signal and reference air kerma measured with an ionization chamber. System performance was evaluated using diagnostic X-ray equipment under various dose rate conditions: a tube voltage of 80 kV, tube currents of 20–160 mA, and an exposure time of 1.0 s. Clinical applicability was also verified under typical exposure conditions for hand (50 kV), abdominal (80 kV), and chest (120 kV) examinations. In the experimental results, it was found that the proposed dosimeter can appropriately measure list-mode datasets and determine the accumulated dose with an accuracy of ±20% for 0.3–10 mGy/s. These findings indicate that the proposed dosimeter can be used for clinical dosimetry during diagnostic X-ray examinations.
- Open Access
- 9 November 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 184
Helpfulness of effective atomic number image in forensic dental identification: Photon-counting computed tomography is suitable
- 9 November 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 184
Open AccessHelpfulness of effective atomic number image in forensic dental identification: Photon-counting computed tomography is suitable