XWXiulan Wang

Xiulan Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiulan Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analytical Calculation Method for Anti-Slip of Main Cables in Three-Tower Suspension Bridges with Spatial Cable Systems

    by Xiulan Wang, Shengbo Chai, Maoqiang Wang, Qian Wu, Kaijie Huang

    To investigate the anti-slip characteristics of the main cables in a three-tower suspension bridge with spatial cable systems, this paper proposes an analytical calculation method for the anti-slip safety factor of the main cables and establishes an equivalent mechanical analysis model for multi-tower suspension bridges with spatial cable systems. Based on the deformation of the towers and cables under live load, as well as the equilibrium relationship of the main cable forces in loaded and unloaded spans, analytical formulas for the anti-slip safety factor of the main cables at the middle tower saddle are derived. A finite element model is developed to validate the formulas. The influence of parameters such as the spatial cable inclination angle, tower-to-cable stiffness ratio, dead-to-live load ratio, sag-to-span ratio, span length, and friction coefficient between the main cable and saddle on the anti-slip safety factor is analyzed. The results indicate that the formula proposed in this paper provides a highly accurate estimation of the slip resistance safety factor for main cables in spatial cable multi-tower suspension bridges. The adoption of spatial main cable configuration enhances the stability of the slip resistance safety factor at the intermediate tower saddle. The slip resistance safety factor of the main cable decreases with the increase in the tower-to-cable stiffness ratio, while it increases with the rise in the sag-to-span ratio. Moreover, the influence of the sag-to-span ratio on the slip resistance stability of the main cable becomes more pronounced with higher tower stiffness. The slip resistance safety factor of the main cable exhibits an approximately linear increase with the rise in the dead-to-live load ratio and the coefficient of friction. Furthermore, the slip resistance safety factor increases with the span length, and this rate of increase becomes more pronounced with smaller sag-to-span ratios. The research findings presented in this paper provide a theoretical basis for the design of spatial cable multi-tower suspension bridges.

  • Open Access

    Influence of Crossing Cable Arrangement on the Static Performance of Long-Span Three-Tower Cable-Stayed Bridges

    by Shengbo Chai, Kaijie Huang, Xiulan Wang

    Insufficient structural stiffness is a key technical challenge that restricts the increase in span of multi-tower cable-stayed bridges. In order to clarify the application effect of crossing cables in long-span, multi-tower cable-stayed bridges, theoretical analysis and the finite element method were used to study the influence of the cable sag effect on the longitudinal constraint stiffness of crossing cables. The longitudinal constraint stiffness formula of the crossing cable was modified by introducing the equivalent elastic modulus to consider the cable sag effect. Based on the stiffness formula, the influence of the main span, initial stress of the crossing cable, and the ratio of the crossing cable area on its restraining effect was analyzed. The finite element model of a three-tower cable-stayed bridge with main span length of 1000 m and 1500 m is established to verify the accuracy of the formula, and the influence of the number of crossing cables and the tower height on the restraining effect of crossing cables is explored. The research results indicate that as the main span length increases, the location of maximum restraining stiffness of crossing cables moves closer to the mid span; increasing the area of crossing cables connected to the mid tower can effectively suppress the deviation of the tower. In addition, increasing the main span length will reduce the restraining effect of the crossing cables, while changes in the height of the towers do not affect the enhancement effect of the crossing cables on structural rigidity.


  • Open Access

    Optimization of Cable Pre-Tension Forces in Multi-Tower Cable-Stayed Bridges with Crossing Cables Considering the Dead Load Allocation

    by Kaijie Huang, Shengbo Chai, Xiulan Wang

    In a multi-tower cable-stayed bridge with crossing cables, the crossing cable pre-tension forces can not only control the vertical displacement of the deck under dead load, but also affect the structural performance. This paper presents an optimization method for pre-tension forces of crossing cable multi tower cable-stayed bridge. This method uses the conic quasi-uniform B-spline curve to represent the distribution of cable pre-tension forces, and the shape of the curve is optimized by particle swarm optimization algorithm. The displacement of the tower and deck under dead load and the displacement of the deck under dead load + live load are taken as optimization objectives, and the two-objective optimization problem is solved by linear weighting method. Finally, the effectiveness of the proposed method is verified by comparing it with practical methods. The calculation results indicate that when the stress level of the cable under dead load is consistent, this method minimizes the vertical displacement of the deck under dead load and live load.


  • Sliding Resistance of Main Cables in Double-Cable Multispan Suspension Bridges

    by Xiulan Wang, Shengbo Chai, Yue Xu

    Sliding resistance of the main cable is of the biggest concern when designing multispan suspension bridges. This paper presents a study on the layout form and sliding-resistance stability of the main cable in a double-cable multispan suspension bridge. It proposes a “top cable to bottom cable” layout, based on which analytical formulas for calculating the sliding-resistance coefficient of the double-cable have been derived. The formulas were verified by finite-element models (FEMs), and the results showed good agreement. The effects of major design parameters on the sliding resistance of the main cable were studied. Analysis shows that the top cable to bottom cable layout can effectively improve the sliding resistance of the main cable, and the bottom cable of the loaded span and the top cable of the unloaded span control the antisliding design of double cable; the sliding resistance of the main cable decreases along with an increase in the ratio of tower stiffness to cable stiffness; the influenc...


  • Deformation Characteristics of Double-Cable Multispan Suspension Bridges

    by Xiulan Wang, Shengbo Chai, Yue Xu

    Structural deformation caused by live loads is a major concern in the design of multispan suspension bridges. Deformation characteristics of double-cable multispan suspension bridges are the focus of this paper. The authors propose a simplified mechanical model of the double-cable multispan suspension bridge for static analysis. Analytical formulas for calculating maximum deflection of the girder in a loaded span were deduced on the basis of the mechanical model. Finite-element models were established to verify formulas, and a comparison of formulas with FEM analysis revealed excellent agreement. The effects of major design parameters on the deformation of double-cable multispan suspension bridges were also studied. Research shows that the distribution of dead loads to the top and bottom cables had little effect on deformation. The sag-to-span ratio of the main cable imposed a significant effect on deformation, and structural deformation decreased with a decrement in top-cable sag or an increment...