FIFarah Abdalsalam Ibrahim

Farah Abdalsalam Ibrahim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Farah Abdalsalam Ibrahim has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical Investigation of Natural Heat Convection in a Triangular Enclosure with a Varying-Diameter Cylindrical Heat Source

    by Safaa H. Faisal, Tahseen A. Jabbar, Ruslan Sabah Abdulrahman, Farah Abdalsalam Ibrahim

    This work offerings a numerical study of natural convection heat transfer within a triangular enclosure having a centrally positioned cylindrical heating source. The effect of the heat source size is investigated by varying its non-dimensional diameter from 0.1 to 0.5. The eating source cylinder and enclosure are maintained at constant temperatures. The buoyancy-driven flow field is analyzed using streamline distributions, non-dimensional velocity magnitudes, and isotherm contours. Results reveal that the size of the internal heating source significantly affects the thermal performance of the combined structure. For small values of , the flow remains weak and localized, with limited convective motion. As increases to moderate values ≈0.3, recirculation regions intensify, velocity fields expand, and thermal plumes rise symmetrically, which indicates enhanced convective transport. However, additional increasing of values leads to flow constriction, reduced circulation strength, and causes less effective heat transfer. It is found that the average Nusselt number decreases with increasing due to diminished temperature gradients and restricted fluid motion despite the larger surface area provided by bigger cylinders. The results are applicable for the design of passive electronic cooling systems, solar thermal collectors, and other natural heat convection-based enclosures.

  • Thermo-Hydraulic Performance of Natural Convection in a Triangular Enclosure with a Vertically Displaced Heat Source

    by Farah Ibrahim Abdalsalam, Ruslan Sabah Abdulrahman, Tahseen A. Jabbar, Safaa Hameed Faisal

    Natural convective in enclosures are very important topics in thermal engineering because they find versatile industrial applications. An internal circular cylinder's vertical position and heat source on fluid flow and heat transfer in a triangular cavity are investigated. Numerical simulations were carried out to analyze variations in the average Nusselt number, streamline topology, temperature distribution, and velocity fields by using ANSYS Fluent. The results show that the Nusselt number rises from approximately 0.91–0.94 at lower positions (Y = 0.1–0.3) to a maximum of about 0.97 near Y = 0.4 driven by intensified thermal gradients and buoyancy-induced circulation. Within the upper-to-mid region (Y = 0.2–0.4) the formation of large adjacent vortices enhances macro-scale mixing, resulting in nearly a 4% improvement in heat transfer relative to the reference case. At mid-level positions (Y = 0.4–0.6) quasi-steady symmetric circulations are sustained, maintaining effective convection with Nu values of 0.95–0.97. In contrast, at higher locations (Y = 0.7–0.9), the weakening of vortex strength leads to flow stagnation and localized deterioration in heat transfer, reducing Nu to about 0.90–0.92. Overall, the findings underscore the critical importance of internal component placement in improving natural cooling performance, and further suggest that the most efficient thermal behavior is achieved when the cylinder and heat source are positioned within 0.2 < Y < 0.4, offering practical guidance for optimizing the thermal design of triangular enclosures.

  • Open Access

    Thermal Performance Optimization for Residential Buildings in Basra City

    by F A Ibrahim, S M Abdulwahid, R S Abdulrahman, M A Mosa

    The present study investigates many parameters in the design of a residential building consisted of 6 floors with a construction area 240m2located in Basra city. This study aims to reduce electric energy consumption utilized for cooling and heating of the building. The parameters which studied included: the effect of building façade, the exterior color of the external walls, the glazing distribution and the shape of the building. eQuest energy simulation program is used to simulate the annual building energy consumption, the program uses the hourly annual collected weather data. The results show that orientation the building façade toward the north direction is the best in the design of the building. The saving in annual electric energy consumption is about 11%. Moreover, the external color of the building has a strong effect on building cooling and heating energy consumption. By utilizing white exterior wall color, the annual electric energy consumption reduced by about 12%. The results also showed that by utilizing proper glazing distribution the electric energy consumption could be reduced by 3%. When all enhancements were combined an optimum building case were found. For the optimum case, the annual electric energy consumption was reduced by 35% compared to the base building case.