Akbar Abdi Saray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Akbar Abdi Saray has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Farzad Isazadeh
Department of Physics, Urmia University, Urmia, Iran
6 shared publications- Farzad Isazadeh
Department of Physics, Urmia University, Urmia, Iran
6 shared publications Mahdieh Mokhtari Dorostkar
Department of Physics, Urmia University, Urmia, Iran
6 shared publicationsFarzad. Isazadeh
Department of Physics, Urmia University, Urmia, Iran
3 shared publicationsHaleh Kangarlou
Department of Physics, Urmia Branch, Islamic Azad University, Urmia, Iran
2 shared publicationsAbbas Nikoo
Department of Organic Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iran
1 shared publication
Latest Publications
- Open Access
- 19 September 2026
- Published by Springer Nature in Scientific Reports
Synthesis and shielding assessment of polymer composite of PVC/Bi2O3/WO3 against photons using GEANT4 and MCNP Monte Carlo nuclear codes
Due to the potential hazards for the environment and humans, protection from nuclear radiations has been a vital issue for researchers. In this work, the shielding properties of four samples (BiW0, BiW2, BiW5, and BiW10) of the PVC/Bi 2 O 3 /WO 3 polymer composites against photons with the energy of 662 keV is studied using experimental, simulation (Monte Carlo codes of GEANT4 and MCNP), and theoretical (online software of XCOM) methods. Polyvinyl chloride (PVC) polymer as a novel polymer matrix has not been applied for shielding aims previously. Moreover, adding double high-Z elements of Bi and W to PVC could be an affordable method for enhancing shielding performance of PVC against photons via decreasing costs and maintaining the structure of the polymer. After synthesizing the PVC/Bi 2 O 3 /WO 3 polymer samples, the XRD and SEM test were taken to assess the structure of the samples. For evaluating the shielding features of the samples, MAC, LAC, HVL, TVL, MFP, Z eff , N eff , and LET parameters were calculated. The values of MAC for the experimental measurements were obtained as (0.0754 ± 0.0068, 0.0835 ± 0.0108, 0.0842 ± 0.0035, and 0.0978 ± 0.0089 cm 2 /g), which are in good agreement with the simulated and theoretical results, with the highest difference of 12%. As the results denote, the values of MAC increase by rising the density and amount of Bi 2 O 3 and WO 3 in the samples. The presence of Bi and W elements in the samples led to an increase in the interactions of photons with materials and higher absorption of photons in the samples. Therefore, the highest MAC results belong to BiW10 (with density of 1.532 g/cm 3 ), which makes the sample the best shield candidate. PVC polymer and their composites can easily be synthesized and shaped. Moreover, due to their suitable density and high flexibility feature, they can easily be moved and used in any part of nuclear imaging and radiation centers.
- 19 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessSynthesis and shielding assessment of polymer composite of PVC/Bi2O3/WO3 against photons using GEANT4 and MCNP Monte Carlo nuclear codes
Due to the potential hazards for the environment and humans, protection from nuclear radiations has been a vital issue for researchers. In this work, the shielding properties of four samples (BiW0, BiW2, BiW5, and BiW10) of the PVC/Bi 2 O 3 /WO 3 polymer composites against photons with the energy of 662 keV is studied using experimental, simulation (Monte Carlo codes of GEANT4 and MCNP), and theoretical (online software of XCOM) methods. Polyvinyl chloride (PVC) polymer as a novel polymer matrix has not been applied for shielding aims previously. Moreover, adding double high-Z elements of Bi and W to PVC could be an affordable method for enhancing shielding performance of PVC against photons via decreasing costs and maintaining the structure of the polymer. After synthesizing the PVC/Bi 2 O 3 /WO 3 polymer samples, the XRD and SEM test were taken to assess the structure of the samples. For evaluating the shielding features of the samples, MAC, LAC, HVL, TVL, MFP, Z eff , N eff , and LET parameters were calculated. The values of MAC for the experimental measurements were obtained as (0.0754 ± 0.0068, 0.0835 ± 0.0108, 0.0842 ± 0.0035, and 0.0978 ± 0.0089 cm 2 /g), which are in good agreement with the simulated and theoretical results, with the highest difference of 12%. As the results denote, the values of MAC increase by rising the density and amount of Bi 2 O 3 and WO 3 in the samples. The presence of Bi and W elements in the samples led to an increase in the interactions of photons with materials and higher absorption of photons in the samples. Therefore, the highest MAC results belong to BiW10 (with density of 1.532 g/cm 3 ), which makes the sample the best shield candidate. PVC polymer and their composites can easily be synthesized and shaped. Moreover, due to their suitable density and high flexibility feature, they can easily be moved and used in any part of nuclear imaging and radiation centers.
- 10 September 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238, 112924
Experimental and Monte Carlo study on shielding properties of polyester/CdO polymer composite against photons using GEANT4 and MCNP codes
- 10 September 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238, 112924
Experimental and Monte Carlo study on shielding properties of polyester/CdO polymer composite against photons using GEANT4 and MCNP codes
- Open Access
- 11 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Synthesis of novel MgO@WO3 nanocomposite material for assessing their photon shielding features: an experimental and Monte Carlo method
- 11 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessSynthesis of novel MgO@WO3 nanocomposite material for assessing their photon shielding features: an experimental and Monte Carlo method
- Open Access
- 1 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Experimental investigation and Monte Carlo validation of PMMA-based WO3- Bi2O3 radiation shield
- 1 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessExperimental investigation and Monte Carlo validation of PMMA-based WO3- Bi2O3 radiation shield
- Open Access
- 19 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
A simulation-based investigation of the production routes of the positron-emitting radionuclide 128Cs using GEANT4, TALYS, and EMPIRE codes for medical applications
Due to its suitable half-life of 3.62 min and positron emission, 128Cs (Iβ+ = 61%; Eβ+ = 2.885 MeV) is a favorable radionuclide for applying in positron emission tomography (PET) imaging. In this work, the production 128Cs radionuclide via the indirect reaction of 133Cs(p,6n)128Ba→128Cs and two new direct reactions of 127I(3He,2n)128Cs and 127Xe(d, n)128Cs was predict using the Monte Carlo GEANT4-10.7 toolkit, the Monte Carlo SRIM-2013-Pro code, the EMPIRE-3.2.3 software, and the TALYS-2.0 package. The range and stopping power values of protons, deuterons, and 3He particles within the 133Cs, 127Xe, and 127I targets were calculated by the GEANT4 and SRIM codes. Moreover, the cross-section of the mentioned reactions was computed utilizing the GEANT4, EMPIRE, TALYS (OMPs, BSFGM, CGCM, and GSM models) codes. To estimate the production yield of the mentioned reactions, the optimum energy range for the 133Cs(p,6n)128Ba→128Cs, 127I(3He,2n)128Cs, and 127Xe(d, n)128Cs reactions were selected (48–68 MeV), (5–10 MeV), and (9–20 MeV), respectively. The previous experimental cross-section and production yield of the 133Cs(p,6n)128Ba→128Cs reaction was compared with the present simulated values of the GEANT4, TALYS, and EMPIRE codes. A good compatibility between the experimental data and simulated values was observed. The good agreement between the experimental data and simulated results is a proof that using a combination of nuclear codes like GEANT4, SRIM, TALYS, and EMPIRE for studying the nuclear reactions can be a good method before performing them practically.
- 19 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessA simulation-based investigation of the production routes of the positron-emitting radionuclide 128Cs using GEANT4, TALYS, and EMPIRE codes for medical applications
Due to its suitable half-life of 3.62 min and positron emission, 128Cs (Iβ+ = 61%; Eβ+ = 2.885 MeV) is a favorable radionuclide for applying in positron emission tomography (PET) imaging. In this work, the production 128Cs radionuclide via the indirect reaction of 133Cs(p,6n)128Ba→128Cs and two new direct reactions of 127I(3He,2n)128Cs and 127Xe(d, n)128Cs was predict using the Monte Carlo GEANT4-10.7 toolkit, the Monte Carlo SRIM-2013-Pro code, the EMPIRE-3.2.3 software, and the TALYS-2.0 package. The range and stopping power values of protons, deuterons, and 3He particles within the 133Cs, 127Xe, and 127I targets were calculated by the GEANT4 and SRIM codes. Moreover, the cross-section of the mentioned reactions was computed utilizing the GEANT4, EMPIRE, TALYS (OMPs, BSFGM, CGCM, and GSM models) codes. To estimate the production yield of the mentioned reactions, the optimum energy range for the 133Cs(p,6n)128Ba→128Cs, 127I(3He,2n)128Cs, and 127Xe(d, n)128Cs reactions were selected (48–68 MeV), (5–10 MeV), and (9–20 MeV), respectively. The previous experimental cross-section and production yield of the 133Cs(p,6n)128Ba→128Cs reaction was compared with the present simulated values of the GEANT4, TALYS, and EMPIRE codes. A good compatibility between the experimental data and simulated values was observed. The good agreement between the experimental data and simulated results is a proof that using a combination of nuclear codes like GEANT4, SRIM, TALYS, and EMPIRE for studying the nuclear reactions can be a good method before performing them practically.
- Open Access
- 24 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Synthesis and evaluating gamma shielding features of YBa2Cu3O7(Bi2O3) ceramic composite using Monte Carlo method via GEANT4 and MCNP codes
In the present study, the four samples of the YBa2Cu3O7/Bi2O3 ceramic composite (Bi0, Bi5, Bi10, and Bi20) were synthesized for evaluating their shielding properties against photons with the energy range of 0.01-15 MeV (including the 137Cs source with the energy of 0.662 MeV). The YBa2Cu3O7 ceramic composite is a favorable superconductor material, which can be used in magnetically levitated transportation, magnetic resonance imaging (MRI), energy systems, and fusion reactors as a fusion magnet. Adding Bi2O3 to the YBa2Cu3O7 can improve the shielding features of it. To study the structure of the samples, an XRD test was taken. Furthermore, the superconductivity property of the sample was assessed by estimating the resistivity of the samples. The GEANT4, MCNP, Phy-X/PSD, and XCOM programs were applied for estimating the protection features of the samples and compared with the experimental values. The LAC, MAC, HVL, TVL, MFP, Zeff, and Neff parameters were computed for the samples. As the results represented, the LAC values of the samples increase with rising the amount of Bi2O3. For instance, in the energy of 0.662 MeV, the LAC values of the Bi0, Bi5, Bi10, and Bi20 samples are (0.4826 ± 0.0015, 0.4660, 0.4630, 0.4756, and 0.4755 cm− 1), (0.4951 ± 0.0031, 0.4778, 0.4768, 0.4902, and 0.4901 cm− 1), (0.5106 ± 0.0024, 0.4939, 0.4913, 0.5056, and 0.5054 cm− 1), and (0.5385 ± 0.0021, 0.5286, 0.5218, 0.5384, and 0.5383 cm− 1) for the experimental measurements and simulation calculations (the GEANT4, MCNP, Phy-X/PSD, and XCOM programs), respectively. As can be seen, the experimental values and simulated results are in good agreement to each other. According to the reported results, the Bi20 sample, with the maximum values of LAC and the highest density, was selected as the best shield candidate against photons than the other samples.
- 24 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessSynthesis and evaluating gamma shielding features of YBa2Cu3O7(Bi2O3) ceramic composite using Monte Carlo method via GEANT4 and MCNP codes
In the present study, the four samples of the YBa2Cu3O7/Bi2O3 ceramic composite (Bi0, Bi5, Bi10, and Bi20) were synthesized for evaluating their shielding properties against photons with the energy range of 0.01-15 MeV (including the 137Cs source with the energy of 0.662 MeV). The YBa2Cu3O7 ceramic composite is a favorable superconductor material, which can be used in magnetically levitated transportation, magnetic resonance imaging (MRI), energy systems, and fusion reactors as a fusion magnet. Adding Bi2O3 to the YBa2Cu3O7 can improve the shielding features of it. To study the structure of the samples, an XRD test was taken. Furthermore, the superconductivity property of the sample was assessed by estimating the resistivity of the samples. The GEANT4, MCNP, Phy-X/PSD, and XCOM programs were applied for estimating the protection features of the samples and compared with the experimental values. The LAC, MAC, HVL, TVL, MFP, Zeff, and Neff parameters were computed for the samples. As the results represented, the LAC values of the samples increase with rising the amount of Bi2O3. For instance, in the energy of 0.662 MeV, the LAC values of the Bi0, Bi5, Bi10, and Bi20 samples are (0.4826 ± 0.0015, 0.4660, 0.4630, 0.4756, and 0.4755 cm− 1), (0.4951 ± 0.0031, 0.4778, 0.4768, 0.4902, and 0.4901 cm− 1), (0.5106 ± 0.0024, 0.4939, 0.4913, 0.5056, and 0.5054 cm− 1), and (0.5385 ± 0.0021, 0.5286, 0.5218, 0.5384, and 0.5383 cm− 1) for the experimental measurements and simulation calculations (the GEANT4, MCNP, Phy-X/PSD, and XCOM programs), respectively. As can be seen, the experimental values and simulated results are in good agreement to each other. According to the reported results, the Bi20 sample, with the maximum values of LAC and the highest density, was selected as the best shield candidate against photons than the other samples.
- Open Access
- 22 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Experimental and Monte Carlo simulation study on photons shielding properties of ZrO2-reinforced polyester composites utilizing GEANT4 and MCNP codes
In this study, the gamma-ray shielding properties of polyester (PE)/ZrO2 polymer composites were evaluated over the energy range of 0.01–10 MeV using the Monte Carlo codes GEANT4 and MCNPX, as well as the software packages XCOM, Phy-X, EpiXS, and NGCal. In addition, experimental investigations were carried out at an energy of 662 keV using a 137Cs source (100 mCi). In this paper, parameters including the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), effective atomic number (Zeff)and effective electron density (Neff) were calculated using the aforementioned software tools, The structural characteristics of the materials were also investigated using XRD and SEM techniques. The simulation results were compared with the experimental data, showing good agreement between them. Furthermore, the lead equivalent thickness (LET) was also investigated, and it was demonstrated that increasing the ZrO2 filler content leads to a gradual increase in the lead equivalent thickness. As observed from the figures and tables, the gamma-ray shielding performance of the PE/ZrO2 composites improves with increasing ZrO2 content, indicating their potential applicability in radiation shielding applications.
- 22 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessExperimental and Monte Carlo simulation study on photons shielding properties of ZrO2-reinforced polyester composites utilizing GEANT4 and MCNP codes
In this study, the gamma-ray shielding properties of polyester (PE)/ZrO2 polymer composites were evaluated over the energy range of 0.01–10 MeV using the Monte Carlo codes GEANT4 and MCNPX, as well as the software packages XCOM, Phy-X, EpiXS, and NGCal. In addition, experimental investigations were carried out at an energy of 662 keV using a 137Cs source (100 mCi). In this paper, parameters including the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), effective atomic number (Zeff)and effective electron density (Neff) were calculated using the aforementioned software tools, The structural characteristics of the materials were also investigated using XRD and SEM techniques. The simulation results were compared with the experimental data, showing good agreement between them. Furthermore, the lead equivalent thickness (LET) was also investigated, and it was demonstrated that increasing the ZrO2 filler content leads to a gradual increase in the lead equivalent thickness. As observed from the figures and tables, the gamma-ray shielding performance of the PE/ZrO2 composites improves with increasing ZrO2 content, indicating their potential applicability in radiation shielding applications.
- 18 February 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 231, 112514
Synthesis and assessment of shielding features of the novel nanocomposite of MgO@PbO against photons via the Monte Carlo GEANT4 and MCNP nuclear codes
- 18 February 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 231, 112514
Synthesis and assessment of shielding features of the novel nanocomposite of MgO@PbO against photons via the Monte Carlo GEANT4 and MCNP nuclear codes
- Open Access
- 20 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Assessing production of 38K suitable for PET imaging via 38Ar(p, n)38K, 38Ar(d,2n)38K, and 36Ar(t, n)38K reactions using GEANT4, EMPIRE, and TALYS codes
In this study, the production of the favorable radioisotope 38K (T1/2 = 7.6 min) for use in Positron Emission Tomography (PET) imaging via the novel reactions 38Ar(p, n)38K, 38Ar(d,2n)38K, and 36Ar(t, n)38K was studied using simulations performed with the GEANT4-10.7, SRIM-2013-Pro, EMPIRE-3.2.3, and TALYS-2.0 nuclear codes. The range and stopping power (SP) for the mentioned reactions were calculated using the GEANT4 and SRIM codes. Moreover, the cross-sections of the above reactions were evaluated using the GEANT4 toolkit, the EMPIRE code, and four methods of the TALYS nuclear package (OMPs, BSFGM, CGCM, and GSM). The experimental data and present simulated values were in good agreement to each other. The maximum cross-section values of the 38Ar(p, n)38K reaction were 59.600 for the experimental data, and 57.938, 167.747, 168.315, 147.513, 168.315, and 156.594 mb for the mentioned codes, respectively, which can be seen that the GEANT4 result is closer to the literature experimental value. In addition, the saturated thick production yield of the 38Ar(p, n)38K reaction (in the optimum energy range of 7–16 MeV), 38Ar(d,2n)38K (in the optimum energy range of 9–20 MeV), and 36Ar(t, n)38K (in the optimum energy range of 1–10 MeV) was estimated by the GEANT4 and TALYS codes. The highest saturated thick production yields for the 38Ar(p, n)38K reaction were 30.392, 32.832, and 25.097 mCi/µA for the previous experimental data, the GEANT4 toolkit, and the TALYS code, respectively. As indicated by the results, using nuclear simulation tools such as those mentioned can be an effective method for predicting nuclear reactions before performing them experimentally, thereby saving time and reducing costs.
- 20 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessAssessing production of 38K suitable for PET imaging via 38Ar(p, n)38K, 38Ar(d,2n)38K, and 36Ar(t, n)38K reactions using GEANT4, EMPIRE, and TALYS codes
In this study, the production of the favorable radioisotope 38K (T1/2 = 7.6 min) for use in Positron Emission Tomography (PET) imaging via the novel reactions 38Ar(p, n)38K, 38Ar(d,2n)38K, and 36Ar(t, n)38K was studied using simulations performed with the GEANT4-10.7, SRIM-2013-Pro, EMPIRE-3.2.3, and TALYS-2.0 nuclear codes. The range and stopping power (SP) for the mentioned reactions were calculated using the GEANT4 and SRIM codes. Moreover, the cross-sections of the above reactions were evaluated using the GEANT4 toolkit, the EMPIRE code, and four methods of the TALYS nuclear package (OMPs, BSFGM, CGCM, and GSM). The experimental data and present simulated values were in good agreement to each other. The maximum cross-section values of the 38Ar(p, n)38K reaction were 59.600 for the experimental data, and 57.938, 167.747, 168.315, 147.513, 168.315, and 156.594 mb for the mentioned codes, respectively, which can be seen that the GEANT4 result is closer to the literature experimental value. In addition, the saturated thick production yield of the 38Ar(p, n)38K reaction (in the optimum energy range of 7–16 MeV), 38Ar(d,2n)38K (in the optimum energy range of 9–20 MeV), and 36Ar(t, n)38K (in the optimum energy range of 1–10 MeV) was estimated by the GEANT4 and TALYS codes. The highest saturated thick production yields for the 38Ar(p, n)38K reaction were 30.392, 32.832, and 25.097 mCi/µA for the previous experimental data, the GEANT4 toolkit, and the TALYS code, respectively. As indicated by the results, using nuclear simulation tools such as those mentioned can be an effective method for predicting nuclear reactions before performing them experimentally, thereby saving time and reducing costs.