Zhengsen Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhengsen Jia has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Qian Xu
National Institute of Metrology, Beijing, China
2 shared publications - Yuzhuo Wang
National Institute of Metrology, Beijing, China
2 shared publications - Aimin Zhang
State Key Laboratory of Polymer Materials Engineering of China, Polymer Research Institute, Sichuan University, Chengdu 610065, China
1 shared publication - Aimin Zhang
National Institute of Metrology
1 shared publication - Daqian Lyu
College of Electronic Engineering, National University of Defense Technology
1 shared publication - Fangxing Liu
China Central Depository and Clearing Company Ltd., Beijing, China
1 shared publication
Latest Publications
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
An FPGA-Based Time-to-Digital Converter With Online Dual-Chain Calibration
This paper introduces an FPGA-based time-to-digital converter with an online dual-chain calibration method to address time resolution and linearity issues arising from the non-uniformity of FPGA internal delay elements. The aim is to enhance the stability and accuracy of time-to-digital converters under varying environmental conditions. We employ an external high-precision clock to generate start-stop calibration signals for real-time monitoring of signal propagation time changes within FPGA components. Two identical delay chains in the time-to-digital converter are managed by a Finite State Machine to switch their roles, ensuring continuous data acquisition and online calibration. Experimental results show that the proposed time-to-digital converter significantly outperforms traditional time interval counter in terms of time linearity, maximum integral nonlinearity, and differential nonlinearity. Within a temperature range of 20°C to 80°C, post-online temperature calibration maintains the root mean square of the TDC below 20 ps, substantially improving performance across different temperature conditions.
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
An FPGA-Based Time-to-Digital Converter With Online Dual-Chain Calibration
This paper introduces an FPGA-based time-to-digital converter with an online dual-chain calibration method to address time resolution and linearity issues arising from the non-uniformity of FPGA internal delay elements. The aim is to enhance the stability and accuracy of time-to-digital converters under varying environmental conditions. We employ an external high-precision clock to generate start-stop calibration signals for real-time monitoring of signal propagation time changes within FPGA components. Two identical delay chains in the time-to-digital converter are managed by a Finite State Machine to switch their roles, ensuring continuous data acquisition and online calibration. Experimental results show that the proposed time-to-digital converter significantly outperforms traditional time interval counter in terms of time linearity, maximum integral nonlinearity, and differential nonlinearity. Within a temperature range of 20°C to 80°C, post-online temperature calibration maintains the root mean square of the TDC below 20 ps, substantially improving performance across different temperature conditions.
- 25 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
An Optimized FIR Predictor for Incomplete Measurement Data of Hydrogen Masers Relative to an Optical Clock
By considering the observation samples of a hydrogen maser relative to an optical clock with time-varying variances, this paper proposes an optimized predictor based on the finite impulse response (FIR) to improve the predictability of hydrogen masers. The design idea and rationality of the predictor were characterized from a theoretical viewpoint, showing its potential predictability for missing partial measurement data or unequal interval measurement data. The prediction results for simulated hydrogen masers reveal its comparable predictability with least squares method (LS). As proof of concept, it was applied to the actual data of typical hydrogen maser relative to a 87 Sr optical lattice clock developed by the National Institute of Metrology (NIM). Compared with the LS, the prediction error after 7 days obtained by the proposed method is ~40 ps smaller than LS.
- 25 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
An Optimized FIR Predictor for Incomplete Measurement Data of Hydrogen Masers Relative to an Optical Clock
By considering the observation samples of a hydrogen maser relative to an optical clock with time-varying variances, this paper proposes an optimized predictor based on the finite impulse response (FIR) to improve the predictability of hydrogen masers. The design idea and rationality of the predictor were characterized from a theoretical viewpoint, showing its potential predictability for missing partial measurement data or unequal interval measurement data. The prediction results for simulated hydrogen masers reveal its comparable predictability with least squares method (LS). As proof of concept, it was applied to the actual data of typical hydrogen maser relative to a 87 Sr optical lattice clock developed by the National Institute of Metrology (NIM). Compared with the LS, the prediction error after 7 days obtained by the proposed method is ~40 ps smaller than LS.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Reducing the Effects of Correlation Between Multiple Clocks on Clock Ensemble Time Scale
SummaryThis paper proposed a new weighting method for clock ensemble: redundant-subspace-weighting (RSW). In this approach, multiple overlapping subspaces are constructed in clock ensemble. By superimposition averaging of different subspace covariances, RSW could reduce the correlations between clocks located in the same laboratory. Preliminary simulation results show its potential capability to enhance the frequency stability of clock ensemble time scale.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Reducing the Effects of Correlation Between Multiple Clocks on Clock Ensemble Time Scale
SummaryThis paper proposed a new weighting method for clock ensemble: redundant-subspace-weighting (RSW). In this approach, multiple overlapping subspaces are constructed in clock ensemble. By superimposition averaging of different subspace covariances, RSW could reduce the correlations between clocks located in the same laboratory. Preliminary simulation results show its potential capability to enhance the frequency stability of clock ensemble time scale.
- 1 September 2018
- Published by Elsevier in Measurement
- Vol. 125, 606-611
Design and implementation of differential AC voltage sampling system based on PJVS
- 1 September 2018
- Published by Elsevier in Measurement
- Vol. 125, 606-611
Design and implementation of differential AC voltage sampling system based on PJVS
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Smart Meter Working Status Evaluation Method Based on Evidence Theory
This paper presents a method to evaluate smart meter working status by analyzing multi-data of smart meters. It is a multi-source data fusion technique based on D-S evidence theory. In the proposed algorithm, entropy method used to compute the weight of indicators, then we use convex function to assign the probabilities of evidence. Finally, we obtain the evaluation working status by D-S evidence theory. The results of simulation indicate the applicability of the approach in real time scenarios.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Smart Meter Working Status Evaluation Method Based on Evidence Theory
This paper presents a method to evaluate smart meter working status by analyzing multi-data of smart meters. It is a multi-source data fusion technique based on D-S evidence theory. In the proposed algorithm, entropy method used to compute the weight of indicators, then we use convex function to assign the probabilities of evidence. Finally, we obtain the evaluation working status by D-S evidence theory. The results of simulation indicate the applicability of the approach in real time scenarios.