Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuzhuo Wang has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improved random pursuit strategy for atomic clock prediction

    by Qianyi Hu, Fangmin Wang, Hao Wang, Qian Xu, Yi Wang, Yuzhuo Wang

    The random pursuit strategy (RPS) has been shown to be an effective method for predicting of atomic clock signals. This paper proposes an improved weight allocating method based on the correlation matrix for RPS. The improved algorithm was used to predict the frequency difference of atomic clocks relative to reference time scale and demonstrates significant improvements over RPS in terms of predictive accuracy, which could be helpful for the generation and maintenance of time scale.

  • Open Access

    CORRIGENDUM: Uncertainty evaluation of the caesium fountain primary frequency standard NIM6 (2025 Metrologia 62 035005)

    by Fasong Zheng, Weiliang Chen, Kun Liu, Shaoyang Dai, Nianfeng Liu, Yuzhuo Wang, Fang Fang

  • Optimized random pursuit strategy for enhancing predictability of on-board atomic clocks

    by Qianyi Hu, Yu Chen, Qian Xu, Fangmin Wang, Lijun Du, Hao Wang, Yuzhuo Wang

  • Open Access

    The Fast Pseudo Random Pursuit Strategy for Atomic Clocks

    by Yu Chen, Qianyi Hu, Dongfang Yang, Yuzhuo Wang

    The Pseudo Random Pursuit Strategy (PRPS) has been proven to be an effective predictive algorithm for atomic clocks. In this paper, the Fast Pseudo Random Pursuit Strategy (FPRPS) is proposed to improve the computational efficiency of PRPS and reduce its time complexity. The core of FPRPS is to replace the inefficient repetitive calculation process in PRPS with an incremental updating process. The FPRPS is employed to predict the frequency difference of atomic clocks relative to UTC(NIM). The experimental results show that FPRPS can significantly improve processing speed without reducing predictive accuracy and stability, compared with PRPS. In experiments, the speed advantage is more than five times. The reduction in computing resource overhead indicates that FPRPS has a wider prospect of applications in engineering practice than PRPS.


  • Absolute frequency measurement of an Al + ion optical clock through a GNSS link to the SI second

    by Zhiyu Ma, Liren Pang, Biao Wang, Rui Gong, Songquan Wei, Yehan Liu, Yiming Gao, Yuzhuo Wang, Zhiyuan Wang, Hongli Liu, et al.

    We report an absolute frequency measurement of the 27 Al + ion 1 S 0 ↔ 3 P 0 optical clock transition, through a GNSS link to International Atomic Time (TAI) to ensure the traceability to the International System of Units (SI) second. The data were taken over a 22 d period, with the absolute frequency measured to be 1 121 015 393 207 856(16) Hz, with a relative standard uncertainty of 1.4 × 10 − 14 . The result confirms the reliability of the 27 Al + ion as a secondary representation of the SI second and contributes to the process of redefining the SI second based on optical transitions.


  • Open Access

    Uncertainty evaluation of the caesium fountain primary frequency standard NIM6

    by Fasong Zheng, Weiliang Chen, Kun Liu, Shaoyang Dai, Nianfeng Liu, Yuzhuo Wang, Fang Fang

    A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term fractional frequency instability of 1.0 × 10 −13 τ −1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.2 × 10 −16 . Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain primary frequency standards through Coordinated Universal Time have demonstrated an agreement within the stated uncertainties.


  • An FPGA-Based Time-to-Digital Converter With Online Dual-Chain Calibration

    by Zhengsen Jia, Yuzhuo Wang, Jie Ding, Qian Xu, Yadongyang Zhu

    This paper introduces an FPGA-based time-to-digital converter with an online dual-chain calibration method to address time resolution and linearity issues arising from the non-uniformity of FPGA internal delay elements. The aim is to enhance the stability and accuracy of time-to-digital converters under varying environmental conditions. We employ an external high-precision clock to generate start-stop calibration signals for real-time monitoring of signal propagation time changes within FPGA components. Two identical delay chains in the time-to-digital converter are managed by a Finite State Machine to switch their roles, ensuring continuous data acquisition and online calibration. Experimental results show that the proposed time-to-digital converter significantly outperforms traditional time interval counter in terms of time linearity, maximum integral nonlinearity, and differential nonlinearity. Within a temperature range of 20°C to 80°C, post-online temperature calibration maintains the root mean square of the TDC below 20 ps, substantially improving performance across different temperature conditions.


  • BDS/GPS Tens of Picoseconds Time Synchronization Method With Application to Communication Network

    by Wei Song, Dayu Yan, Chuang Shi, Fu Zheng, Caicong Wu, Guifei Jing, Yuzhuo Wang, Xiaolin Meng

    Time synchronization is a critical requirement in sixth-generation (6G) communication systems and Internet of Things (IoT) applications. However, the standard timing services provided by global navigation satellite systems (GNSS) are increasingly unable to meet the growing demands for precision and stability in modern networks. The proposed system leverages a single-difference time transfer (SDPT) method to achieve tens of picoseconds precision, enabling effective clock disciplining for oven-controlled crystal oscillators (OCXO). A clock disciplining within a phase-locked loop (PLL) structure further optimizes the output of time and frequency signals, enhancing OCXO stability. Additionally, a differential precise time synchronization system (DPTSS) by BeiDou navigation satellite system (BDS)/ global positioning system (GPS) is developed to deliver high-precision time reference signals for communication networks. Experimental results demonstrate that the real-time 1 pulse-per-second (1PPS) interval achieved by the BDS/GPS time link is better than 0.1 ns, with long-term frequency stability reaching the 10-16 level. Furthermore, the proposed system achieves a 1PPS signal synchronization precision of 0.73 ns in communication networks, significantly outperforming the other state-of-the-art methods.


  • A 6 month-long real-time time scale steered to NIM-Sr1 optical lattice clock

    by Lin Zhu, Qiang Wang, Yuzhuo Wang, Yige Lin, Dongfang Yang, Ye Li, Tao Yang, Fei Meng, Baike Lin, Haochen Tian, et al.

    NIM-Sr1 optical lattice clock has been operated intermittently for seven consecutive months with an operation uptime around 13.8%, which serves as the reference to steer a hydrogen maser for generating a real-time time scale TS(Sr1). The peak-to-peak time difference of TS(Sr1) compared to UTC is 1.8 ns within 180 d and is less than 0.5 ns within the last month, after correcting the time error induced by a time transfer link abnormality. A dedicated automation system with hardware and software is developed to monitor the operation status of NIM-Sr1, process the measurement data, and periodically predict the hydrogen maser frequency. According to the simulation results, a composite algorithm based on both Kalman filtering (KF) and weighted least squares fitting (WLSF) is utilized for generating TS(Sr1). The KF is utilized when the unavailability of NIM-Sr1 is shorter than 1 d, and the WLSF with fitting interval T fit = 30  d is utilized in other conditions leveraging the long-term predictability of the hydrogen maser. In addition, it is demonstrated by simulation and the post-processing of earlier experimental data that, a time scale with smaller time error can be achieved by shortening the WLSF interval from 30 d to about 5 d under the condition of sufficient measurement data points for reducing the statistical error.


  • An Optimized FIR Predictor for Incomplete Measurement Data of Hydrogen Masers Relative to an Optical Clock

    by Qian Xu, Zhengsen Jia, Yue Zhang, Yuzhuo Wang, Aimin Zhang

    By considering the observation samples of a hydrogen maser relative to an optical clock with time-varying variances, this paper proposes an optimized predictor based on the finite impulse response (FIR) to improve the predictability of hydrogen masers. The design idea and rationality of the predictor were characterized from a theoretical viewpoint, showing its potential predictability for missing partial measurement data or unequal interval measurement data. The prediction results for simulated hydrogen masers reveal its comparable predictability with least squares method (LS). As proof of concept, it was applied to the actual data of typical hydrogen maser relative to a 87 Sr optical lattice clock developed by the National Institute of Metrology (NIM). Compared with the LS, the prediction error after 7 days obtained by the proposed method is ~40 ps smaller than LS.