Edwin Heijman
Edwin Heijman has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Holger Grüll
Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
4 shared publications - Lukas Sebeke
Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital of Cologne, University of Cologne, Cologne, Germany
4 shared publications - Bram de Jager
Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
3 shared publications - Daniel A. Deenen
Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
3 shared publications - W. P. Maurice H. Heemels
Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
3 shared publications - Alexandra Claudia Maul
Experimental Medicine, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
2 shared publications
Latest Publications
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (4) , 1926-1933
Target-Conformal Optimization-Based Actuator Placement for Ultrasound-Mediated Hyperthermia in Cancer Treatments
In hyperthermia for cancer treatments, tumors are heated to improve the outcome of radio-and chemotherapies. Using extracorporeal high-intensity focused ultrasound (HIFU) transducers, the heating can be applied noninvasively, accurately, and with high acoustic power. The heating location can be changed by electronic beam steering, within the transducer’s small local heating range, and by mechanically repositioning the transducer, which effectively shifts the local range to enable the treatment of larger tumors. An important problem is the selection of the sonication points, i.e., the discrete locations reachable by electronic beam steering, and the admissible mechanical transducer positions, which must be performed prior to treatment, and can be seen as an actuator selection problem. Clearly, the selected sonication points and transducer positions have a major impact on the achievable tumor temperatures, and their number is directly related to the controller’s complexity and, thereby, real-time feasibility. To address this challenging problem, this brief presents a target-conformal optimization-based actuator placement procedure, designed to assist the clinician in enabling maximum treatment quality using only a limited number of sonication points and transducer positions. The method is computationally tractable, and takes into account the specific tumor geometry and tissue properties.
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (4) , 1926-1933
Target-Conformal Optimization-Based Actuator Placement for Ultrasound-Mediated Hyperthermia in Cancer Treatments
In hyperthermia for cancer treatments, tumors are heated to improve the outcome of radio-and chemotherapies. Using extracorporeal high-intensity focused ultrasound (HIFU) transducers, the heating can be applied noninvasively, accurately, and with high acoustic power. The heating location can be changed by electronic beam steering, within the transducer’s small local heating range, and by mechanically repositioning the transducer, which effectively shifts the local range to enable the treatment of larger tumors. An important problem is the selection of the sonication points, i.e., the discrete locations reachable by electronic beam steering, and the admissible mechanical transducer positions, which must be performed prior to treatment, and can be seen as an actuator selection problem. Clearly, the selected sonication points and transducer positions have a major impact on the achievable tumor temperatures, and their number is directly related to the controller’s complexity and, thereby, real-time feasibility. To address this challenging problem, this brief presents a target-conformal optimization-based actuator placement procedure, designed to assist the clinician in enabling maximum treatment quality using only a limited number of sonication points and transducer positions. The method is computationally tractable, and takes into account the specific tumor geometry and tissue properties.
- Open Access
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 1174-1187
Visualization of thermal washout due to spatiotemporally heterogenous perfusion in the application of a model-based control algorithm for MR-HIFU mediated hyperthermia
This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the...
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 1174-1187
Open AccessVisualization of thermal washout due to spatiotemporally heterogenous perfusion in the application of a model-based control algorithm for MR-HIFU mediated hyperthermia
This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the...
- Open Access
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 6637-6643
Mixed-integer model predictive control for large-area MR-HIFU hyperthermia in cancer therapy
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 6637-6643
Open AccessMixed-integer model predictive control for large-area MR-HIFU hyperthermia in cancer therapy
- Open Access
- 1 January 2020
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 37 (1) , 786-798
Feasibility study of MR-guided pancreas ablation using high-intensity focused ultrasound in a healthy swine model
Purpose: Pancreatic cancer is typically diagnosed in a late stage with limited therapeutic options. For those patients, ultrasound-guided high-intensity focused ultrasound (US-HIFU) can improve local control and alleviate pain. However, MRI-guided HIFU (MR-HIFU) has not yet been studied extensively in this context. To facilitate related research and accelerate clinical translation, we report a workflow for the in vivo HIFU ablation of the porcine pancreas under MRI guidance. Materials and methods: The pancreases of five healthy German landrace pigs (35–58 kg) were sonicated using a clinical MR-HIFU system. Acoustic access to the pancreas was supported by a specialized diet and a hydrogel compression device for bowel displacement. Organ motion was suspended using periods of apnea. The size of the resulting thermal lesions was assessed using the thermal threshold- and dose profiles, non-perfused volume, and gross examination. The effect of the compression device on beam path length was assessed using MRI imaging. Results: Eight of ten treatments resulted in clearly visible damage in the target tissue upon gross examination. Five treatments resulted in coagulative necrosis. Good agreement between the four metrics for lesion size and a clear correlation between the delivered energy dose and the resulting lesion size were found. The compression device notably shortened the intra-abdominal beam path. Conclusions: We demonstrated a workflow for HIFU treatment of the porcine pancreas in-vivo under MRI-guidance. This development bears significance for the development of MR-guided HIFU interventions on the pancreas as the pig is the preferred animal model for the translation of pre-clinical research into clinical application.
- 1 January 2020
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 37 (1) , 786-798
Open AccessFeasibility study of MR-guided pancreas ablation using high-intensity focused ultrasound in a healthy swine model
Purpose: Pancreatic cancer is typically diagnosed in a late stage with limited therapeutic options. For those patients, ultrasound-guided high-intensity focused ultrasound (US-HIFU) can improve local control and alleviate pain. However, MRI-guided HIFU (MR-HIFU) has not yet been studied extensively in this context. To facilitate related research and accelerate clinical translation, we report a workflow for the in vivo HIFU ablation of the porcine pancreas under MRI guidance. Materials and methods: The pancreases of five healthy German landrace pigs (35–58 kg) were sonicated using a clinical MR-HIFU system. Acoustic access to the pancreas was supported by a specialized diet and a hydrogel compression device for bowel displacement. Organ motion was suspended using periods of apnea. The size of the resulting thermal lesions was assessed using the thermal threshold- and dose profiles, non-perfused volume, and gross examination. The effect of the compression device on beam path length was assessed using MRI imaging. Results: Eight of ten treatments resulted in clearly visible damage in the target tissue upon gross examination. Five treatments resulted in coagulative necrosis. Good agreement between the four metrics for lesion size and a clear correlation between the delivered energy dose and the resulting lesion size were found. The compression device notably shortened the intra-abdominal beam path. Conclusions: We demonstrated a workflow for HIFU treatment of the porcine pancreas in-vivo under MRI-guidance. This development bears significance for the development of MR-guided HIFU interventions on the pancreas as the pig is the preferred animal model for the translation of pre-clinical research into clinical application.
- Open Access
- 1 January 2019
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 36 (1) , 1039-1049
Model predictive control for MR-HIFU-mediated, uniform hyperthermia
Purpose: In local hyperthermia, precise temperature control throughout the entire target region is key for swift, safe, and effective treatment. In this article, we present a model predictive control (MPC) algorithm providing voxel-level temperature control in magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) and assess the improvement in performance it provides over the current state of the art. Materials and methods: The influence of model detail on the prediction quality and runtime of the controller is evaluated and a tissue mimicking phantom is characterized using the resulting model. Next, potential problems arising from modeling errors are evaluated in silico and in the characterized phantom. Finally, the controller’s performance is compared to the current state-of-the-art hyperthermia controller in side-by-side experiments. Results: Modeling diffusion by heat exchange between four neighboring voxels achieves high predictive performance and results in runtimes suited for real-time control. Erroneous model parameters deteriorate the MPC’s performance. Using models derived from thermometry data acquired during low powered test sonications, however, high control performance is achieved. In a direct comparison with the state-of-the-art hyperthermia controller, the MPC produces smaller tracking errors and tighter temperature distributions, both in a homogeneous target and near a localized heat sink. Conclusion: Using thermal models deduced from low-powered test sonications, the proposed MPC algorithm provides good performance in phantoms. In direct comparison to the current state-of-the-art hyperthermia controller, MPC performs better due to the more finely tuned heating patterns and therefore constitutes an important step toward stable, uniform hyperthermia.
- 1 January 2019
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 36 (1) , 1039-1049
Open AccessModel predictive control for MR-HIFU-mediated, uniform hyperthermia
Purpose: In local hyperthermia, precise temperature control throughout the entire target region is key for swift, safe, and effective treatment. In this article, we present a model predictive control (MPC) algorithm providing voxel-level temperature control in magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) and assess the improvement in performance it provides over the current state of the art. Materials and methods: The influence of model detail on the prediction quality and runtime of the controller is evaluated and a tissue mimicking phantom is characterized using the resulting model. Next, potential problems arising from modeling errors are evaluated in silico and in the characterized phantom. Finally, the controller’s performance is compared to the current state-of-the-art hyperthermia controller in side-by-side experiments. Results: Modeling diffusion by heat exchange between four neighboring voxels achieves high predictive performance and results in runtimes suited for real-time control. Erroneous model parameters deteriorate the MPC’s performance. Using models derived from thermometry data acquired during low powered test sonications, however, high control performance is achieved. In a direct comparison with the state-of-the-art hyperthermia controller, the MPC produces smaller tracking errors and tighter temperature distributions, both in a homogeneous target and near a localized heat sink. Conclusion: Using thermal models deduced from low-powered test sonications, the proposed MPC algorithm provides good performance in phantoms. In direct comparison to the current state-of-the-art hyperthermia controller, MPC performs better due to the more finely tuned heating patterns and therefore constitutes an important step toward stable, uniform hyperthermia.