Bram de Jager
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Bram de Jager has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Maarten Steinbuch
Eindhoven University of Technology
7 shared publications - Frank Willems
Eindhoven University of Technology, Eindhoven, The Netherlands
5 shared publications - Daniel A. Deenen
Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
4 shared publications - W. P. Maurice H. Heemels
Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
4 shared publications - Edwin Heijman
Philips Research, Eindhoven, The Netherlands
3 shared publications - Holger Grüll
Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, Cologne, Germany
3 shared publications
Latest Publications
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (4) , 1926-1933
Target-Conformal Optimization-Based Actuator Placement for Ultrasound-Mediated Hyperthermia in Cancer Treatments
In hyperthermia for cancer treatments, tumors are heated to improve the outcome of radio-and chemotherapies. Using extracorporeal high-intensity focused ultrasound (HIFU) transducers, the heating can be applied noninvasively, accurately, and with high acoustic power. The heating location can be changed by electronic beam steering, within the transducer’s small local heating range, and by mechanically repositioning the transducer, which effectively shifts the local range to enable the treatment of larger tumors. An important problem is the selection of the sonication points, i.e., the discrete locations reachable by electronic beam steering, and the admissible mechanical transducer positions, which must be performed prior to treatment, and can be seen as an actuator selection problem. Clearly, the selected sonication points and transducer positions have a major impact on the achievable tumor temperatures, and their number is directly related to the controller’s complexity and, thereby, real-time feasibility. To address this challenging problem, this brief presents a target-conformal optimization-based actuator placement procedure, designed to assist the clinician in enabling maximum treatment quality using only a limited number of sonication points and transducer positions. The method is computationally tractable, and takes into account the specific tumor geometry and tissue properties.
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (4) , 1926-1933
Target-Conformal Optimization-Based Actuator Placement for Ultrasound-Mediated Hyperthermia in Cancer Treatments
In hyperthermia for cancer treatments, tumors are heated to improve the outcome of radio-and chemotherapies. Using extracorporeal high-intensity focused ultrasound (HIFU) transducers, the heating can be applied noninvasively, accurately, and with high acoustic power. The heating location can be changed by electronic beam steering, within the transducer’s small local heating range, and by mechanically repositioning the transducer, which effectively shifts the local range to enable the treatment of larger tumors. An important problem is the selection of the sonication points, i.e., the discrete locations reachable by electronic beam steering, and the admissible mechanical transducer positions, which must be performed prior to treatment, and can be seen as an actuator selection problem. Clearly, the selected sonication points and transducer positions have a major impact on the achievable tumor temperatures, and their number is directly related to the controller’s complexity and, thereby, real-time feasibility. To address this challenging problem, this brief presents a target-conformal optimization-based actuator placement procedure, designed to assist the clinician in enabling maximum treatment quality using only a limited number of sonication points and transducer positions. The method is computationally tractable, and takes into account the specific tumor geometry and tissue properties.
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 30 (1) , 142-152
Incorporating Prior Knowledge in Local Parametric Modeling for Frequency Response Measurements: Applied to Thermal/Mechanical Systems
Frequency response function (FRF) identification is a key step in experimental modeling of many applications, including mechatronic systems. Applying these techniques to systems where measurement time is limited leads to a situation where the accuracy of the identified model is deteriorated by transient dynamics. This article aims to develop an identification procedure that mitigates these transient dynamics by employing local parametric modeling techniques. To improve the modeling accuracy, prior knowledge is suitably incorporated in the procedure while at the same time allowing for rational parameterizations that maintain a closed-form solution. The prior knowledge is exploited in a relevant local frequency range using a specific Möbius transformation. Preexisting methods, including the commonly used local polynomial method, are recovered as a special case. The presented framework leads to accurate identification results in a simulation study as well as on experimental measurement data.
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 30 (1) , 142-152
Incorporating Prior Knowledge in Local Parametric Modeling for Frequency Response Measurements: Applied to Thermal/Mechanical Systems
Frequency response function (FRF) identification is a key step in experimental modeling of many applications, including mechatronic systems. Applying these techniques to systems where measurement time is limited leads to a situation where the accuracy of the identified model is deteriorated by transient dynamics. This article aims to develop an identification procedure that mitigates these transient dynamics by employing local parametric modeling techniques. To improve the modeling accuracy, prior knowledge is suitably incorporated in the procedure while at the same time allowing for rational parameterizations that maintain a closed-form solution. The prior knowledge is exploited in a relevant local frequency range using a specific Möbius transformation. Preexisting methods, including the commonly used local polynomial method, are recovered as a special case. The presented framework leads to accurate identification results in a simulation study as well as on experimental measurement data.
- Open Access
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 1174-1187
Visualization of thermal washout due to spatiotemporally heterogenous perfusion in the application of a model-based control algorithm for MR-HIFU mediated hyperthermia
This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the...
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 1174-1187
Open AccessVisualization of thermal washout due to spatiotemporally heterogenous perfusion in the application of a model-based control algorithm for MR-HIFU mediated hyperthermia
This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the...
- 2 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (6) , 2351-2365
Offset-Free Model Predictive Temperature Control for Ultrasound-Based Hyperthermia Cancer Treatments
Heating cancer cells over an extended period of time, referred to as hyperthermia, has been proven to enhance the effects of chemotherapy and radiotherapy without inducing additional toxicity or undesirable side effects, and is therefore considered a highly valuable adjuvant therapy in cancer treatment. In this work, a model predictive control (MPC) setup is developed for improving performance and robustness in regulating the temperature for magnetic-resonance-guided high-intensity focused ultrasound (MR-HIFU) hyperthermia treatments. The proposed control design incorporates a disturbance estimator as encountered in offset-free MPC that is able to remove the steady-state temperature error caused by plant-model mismatch. For the considered healthcare application, such modeling errors are inevitable in practice due to the high variability of tissue properties in patients, some of which even exhibit time- and temperature-dependent behavior due to the body’s thermoregulatory response, combined with the fact that extensive model identification is undesirable in the clinic. The controller’s performance is demonstrated by means of in vivo experiments on a porcine thigh muscle using a clinical MR-HIFU treatment setup.
- 2 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (6) , 2351-2365
Offset-Free Model Predictive Temperature Control for Ultrasound-Based Hyperthermia Cancer Treatments
Heating cancer cells over an extended period of time, referred to as hyperthermia, has been proven to enhance the effects of chemotherapy and radiotherapy without inducing additional toxicity or undesirable side effects, and is therefore considered a highly valuable adjuvant therapy in cancer treatment. In this work, a model predictive control (MPC) setup is developed for improving performance and robustness in regulating the temperature for magnetic-resonance-guided high-intensity focused ultrasound (MR-HIFU) hyperthermia treatments. The proposed control design incorporates a disturbance estimator as encountered in offset-free MPC that is able to remove the steady-state temperature error caused by plant-model mismatch. For the considered healthcare application, such modeling errors are inevitable in practice due to the high variability of tissue properties in patients, some of which even exhibit time- and temperature-dependent behavior due to the body’s thermoregulatory response, combined with the fact that extensive model identification is undesirable in the clinic. The controller’s performance is demonstrated by means of in vivo experiments on a porcine thigh muscle using a clinical MR-HIFU treatment setup.
- 9 September 2020
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 143 (1)
Cycle-to-Cycle Multipulse Fuel-Injection Control for Advanced Diesel Combustion in Changing and Disturbed Operating Points
When controlled in an open-loop fashion, both stationary and dynamical diesel engine performance can deteriorate due to disturbances. Although cycle-to-cycle fuel injection control has the potential of reducing the performance degradation by manipulating the fueling profile in real time, this potential has not been thoroughly studied. This is especially true for multipulse fuel injection, due to the lack of a controller design method with closed-loop reference tracking performance guarantees. In this paper, we introduce a systematic design method for multivariable cycle-to-cycle fuel injection control. The design method is based on several local linearizations to address varying combustion behavior due to different engine speeds, torques, and disturbances. This leads to a controller that is robust with respect to all the local linearizations. Experimental results show that the controller works well in both stationary and dynamical operating conditions, and has fast dynamical performance (settling time less than 1.5 (s)). Moreover, experimental data show that cycle-to-cycle fuel injection control is robust against the uncertainties introduced by disturbed rail pressure and swirl valve position.
- 9 September 2020
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 143 (1)
Cycle-to-Cycle Multipulse Fuel-Injection Control for Advanced Diesel Combustion in Changing and Disturbed Operating Points
When controlled in an open-loop fashion, both stationary and dynamical diesel engine performance can deteriorate due to disturbances. Although cycle-to-cycle fuel injection control has the potential of reducing the performance degradation by manipulating the fueling profile in real time, this potential has not been thoroughly studied. This is especially true for multipulse fuel injection, due to the lack of a controller design method with closed-loop reference tracking performance guarantees. In this paper, we introduce a systematic design method for multivariable cycle-to-cycle fuel injection control. The design method is based on several local linearizations to address varying combustion behavior due to different engine speeds, torques, and disturbances. This leads to a controller that is robust with respect to all the local linearizations. Experimental results show that the controller works well in both stationary and dynamical operating conditions, and has fast dynamical performance (settling time less than 1.5 (s)). Moreover, experimental data show that cycle-to-cycle fuel injection control is robust against the uncertainties introduced by disturbed rail pressure and swirl valve position.
- Open Access
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 6637-6643
Mixed-integer model predictive control for large-area MR-HIFU hyperthermia in cancer therapy
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 6637-6643
Open AccessMixed-integer model predictive control for large-area MR-HIFU hyperthermia in cancer therapy
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4618-4623
Thermo-Mechanical Behavior in Precision Motion Control: Unified Framework for Fast and Accurate FRF Identification
The achievement of higher accuracy and throughput in mechatronic systems using motion control has led to the situation where the thermal effects in mechatronic systems have become increasingly important and have to be actively controlled. In view of achieving overall control performance of interacting thermal and mechanical dynamics, in this paper it is aimed to develop an identification approach that delivers the required model for thermo-mechanical control. A novel technique is developed that leads to a significant reduction in both the estimation error and measurement time compared to traditional identification methods. The proposed approach is applied to a thermo-mechanical system in an extensive experimental study.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4618-4623
Thermo-Mechanical Behavior in Precision Motion Control: Unified Framework for Fast and Accurate FRF Identification
The achievement of higher accuracy and throughput in mechatronic systems using motion control has led to the situation where the thermal effects in mechatronic systems have become increasingly important and have to be actively controlled. In view of achieving overall control performance of interacting thermal and mechanical dynamics, in this paper it is aimed to develop an identification approach that delivers the required model for thermo-mechanical control. A novel technique is developed that leads to a significant reduction in both the estimation error and measurement time compared to traditional identification methods. The proposed approach is applied to a thermo-mechanical system in an extensive experimental study.
- 8 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 2 (3) , 309-314
$\mathcal{H}_{\text{2}}$ -Norm-Based Multi-Pulse Diesel Fuel Injection Control With Minimal Cyclic Combustion VariationDue to varying in-cylinder conditions, cyclic combustion variation leads to fluctuating and deteriorated diesel engine performance. In this paper, we study both the deterministic and the stochastic cyclic variation of a closed-loop controlled combustion process with a cycle-to-cycle fuel injection controller using in-cylinder pressure information. A controller design method is proposed that yields a stabilizing controller with fast dynamical performance, while minimizing the unavoidable amplification of the stochastic cyclic variation. Following the design method with different design parameters, multiple controllers are designed and experimentally tested using a single-cylinder engine test setup. The reference tracking results illustrate the trade-off between the controllers’ capability to reduce the deterministic or to avoid amplification of the stochastic cyclic combustion variation.
- 8 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 2 (3) , 309-314
$\mathcal{H}_{\text{2}}$ -Norm-Based Multi-Pulse Diesel Fuel Injection Control With Minimal Cyclic Combustion VariationDue to varying in-cylinder conditions, cyclic combustion variation leads to fluctuating and deteriorated diesel engine performance. In this paper, we study both the deterministic and the stochastic cyclic variation of a closed-loop controlled combustion process with a cycle-to-cycle fuel injection controller using in-cylinder pressure information. A controller design method is proposed that yields a stabilizing controller with fast dynamical performance, while minimizing the unavoidable amplification of the stochastic cyclic variation. Following the design method with different design parameters, multiple controllers are designed and experimentally tested using a single-cylinder engine test setup. The reference tracking results illustrate the trade-off between the controllers’ capability to reduce the deterministic or to avoid amplification of the stochastic cyclic combustion variation.
- 23 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 25 (4) , 1264-1277
Convex Modeling and Optimization of a Vehicle Powertrain Equipped With a Generator–Turbine Throttle Unit
This paper investigates an internal combustion (gasoline) engine throttled by a generator-turbine unit. Apart from throttling, the purpose of this device is to complement the operation of a conventional car alternator and support its downsizing by introducing an additional source of energy for the electric auxiliaries. Its energy recovery potential is examined by employing a novel, convex approach to modeling and optimization of the resulting vehicle powertrain. For a given gear-shifting strategy, the proposed method allows the computation of optimal control trajectories, e.g., the optimal engine fuel, alternator, and turbine power, as well as of optimal design parameters, i.e., the optimal battery, alternator and turbogenerator size. The conducted numerical case study shows that a generator-turbine throttle unit has a potential to reduce the total operational (fuel) and component (battery, alternator, and turbogenerator) costs by typically 2%-6%, depending on factors such as the engine size and the choice of a driving cycle.
- 23 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 25 (4) , 1264-1277
Convex Modeling and Optimization of a Vehicle Powertrain Equipped With a Generator–Turbine Throttle Unit
This paper investigates an internal combustion (gasoline) engine throttled by a generator-turbine unit. Apart from throttling, the purpose of this device is to complement the operation of a conventional car alternator and support its downsizing by introducing an additional source of energy for the electric auxiliaries. Its energy recovery potential is examined by employing a novel, convex approach to modeling and optimization of the resulting vehicle powertrain. For a given gear-shifting strategy, the proposed method allows the computation of optimal control trajectories, e.g., the optimal engine fuel, alternator, and turbine power, as well as of optimal design parameters, i.e., the optimal battery, alternator and turbogenerator size. The conducted numerical case study shows that a generator-turbine throttle unit has a potential to reduce the total operational (fuel) and component (battery, alternator, and turbogenerator) costs by typically 2%-6%, depending on factors such as the engine size and the choice of a driving cycle.
- 1 January 2015
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 48 (15) , 181-186
Cylinder Pressure-based Combustion Control with Multi-pulse Fuel Injection
- 1 January 2015
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 48 (15) , 181-186
Cylinder Pressure-based Combustion Control with Multi-pulse Fuel Injection