Beomjune Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Beomjune Shin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ho-Young Kim
Department of Mechanical Engineering, Seoul National University
2 shared publications - Jimin Lee
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
2 shared publications - Woon-Hong Yeo
George W. Woodruff School of Mechanical Engineering Georgia Institute of Technology Atlanta Georgia USA
2 shared publications - Arianna Lee
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
1 shared publication Eugene Kim
Wearable Intelligent Systems and Healthcare Center (WISH Center) at the Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, USA
1 shared publication- Gee Ho Park
GeneOne Life Science Inc, Seoul, Korea
1 shared publication
Latest Publications
- Open Access
- 10 December 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (2) , 273-285
Capillary-driven, superhydrophilic microfluidic retainer for continuous salivary glucose monitoring
Salivary glucose monitoring provides a non-invasive alternative to blood-based diabetes tests; however, low analyte levels and unstable microfluidic wetting have hindered its translation. Here, we introduce a retainer-based microfluidic system that integrates a capillary-driven, superhydrophilic microchannel with a miniaturized three-electrode enzymatic sensor for continuous salivary glucose monitoring. This device maintains sustained hydrophilicity for at least 120 days without compromising flexibility or biocompatibility. The gold working electrode, functionalized with glucose oxidase immobilized in a carbon nanotube–chitosan matrix and a thin glutaraldehyde overlayer, offers sensitive and stable detection. The integrated sensor shows the chronoamperometric sensitivity of 15.48 μA mM-1 cm-2, and a limit of detection of < 42 μM. The in-vitro measurements using glucose-spiked artificial saliva show the reproduced postprandial profiles with rapid signal stabilization and high run-to-run repeatability over three cycles. Overall, this work captures the potential of the retainer-based microfluidic system as a practical pathway toward continuous, non-invasive, salivary glucose monitoring.
- 10 December 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (2) , 273-285
Open AccessCapillary-driven, superhydrophilic microfluidic retainer for continuous salivary glucose monitoring
Salivary glucose monitoring provides a non-invasive alternative to blood-based diabetes tests; however, low analyte levels and unstable microfluidic wetting have hindered its translation. Here, we introduce a retainer-based microfluidic system that integrates a capillary-driven, superhydrophilic microchannel with a miniaturized three-electrode enzymatic sensor for continuous salivary glucose monitoring. This device maintains sustained hydrophilicity for at least 120 days without compromising flexibility or biocompatibility. The gold working electrode, functionalized with glucose oxidase immobilized in a carbon nanotube–chitosan matrix and a thin glutaraldehyde overlayer, offers sensitive and stable detection. The integrated sensor shows the chronoamperometric sensitivity of 15.48 μA mM-1 cm-2, and a limit of detection of < 42 μM. The in-vitro measurements using glucose-spiked artificial saliva show the reproduced postprandial profiles with rapid signal stabilization and high run-to-run repeatability over three cycles. Overall, this work captures the potential of the retainer-based microfluidic system as a practical pathway toward continuous, non-invasive, salivary glucose monitoring.
- Open Access
- 9 August 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-11
All-in-one wearable drug efficacy assessment systems for bulbar muscle function using amyotrophic lateral sclerosis animal models
Preclinical studies are crucial for developing amyotrophic lateral sclerosis drugs. Current FDA-approved drugs have been created by monitoring limb muscle function and histological analysis of amyotrophic lateral sclerosis model animals. Drug candidates for this disease have yet to be tested for bulbar-onset type due to the limitations of traditional preclinical tools: excessive animal use and discrete detection of disease progress. Here, our study introduces an all-in-one, wireless, integrated wearable system for facilitating continuous drug efficacy assessment of dysphagia-related muscles in animals during natural eating behaviors. By incorporating a kirigami-based strain-isolation mechanism, this device mounted on the skin of animals mitigates electromyography signal contamination caused by unpredictable animal movements. Our findings indicate this system, measuring the progression of motor neuron denervation, offers high precision in monitoring drug effects on dysphagia-responsible bulbar muscles. This study paves the way for more humane and efficient approaches to developing treatment solutions for degenerative neuromuscular diseases.
- 9 August 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-11
Open AccessAll-in-one wearable drug efficacy assessment systems for bulbar muscle function using amyotrophic lateral sclerosis animal models
Preclinical studies are crucial for developing amyotrophic lateral sclerosis drugs. Current FDA-approved drugs have been created by monitoring limb muscle function and histological analysis of amyotrophic lateral sclerosis model animals. Drug candidates for this disease have yet to be tested for bulbar-onset type due to the limitations of traditional preclinical tools: excessive animal use and discrete detection of disease progress. Here, our study introduces an all-in-one, wireless, integrated wearable system for facilitating continuous drug efficacy assessment of dysphagia-related muscles in animals during natural eating behaviors. By incorporating a kirigami-based strain-isolation mechanism, this device mounted on the skin of animals mitigates electromyography signal contamination caused by unpredictable animal movements. Our findings indicate this system, measuring the progression of motor neuron denervation, offers high precision in monitoring drug effects on dysphagia-responsible bulbar muscles. This study paves the way for more humane and efficient approaches to developing treatment solutions for degenerative neuromuscular diseases.
- 26 October 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 18 (4) , 044061
Thermodynamics of Hygroresponsive Soft Engines: Cycle Analysis and Work Ratio
Soft materials that respond to external stimuli, such as moisture, heat, and light, can convert the environmental energy into mechanical motions, and thus can be considered engines. The energy-conversion process within the soft-materials-based engines is fundamentally different from that of conventional heat engines utilizing gaseous media, but has been rarely studied to date. Here we construct a theoretical framework to analyze the thermodynamic performance of humidity-responsive soft actuators, as a canonical model of soft engines, which operate in a similar manner to such motile plants as wild wheat seeds and pine cones. Considering the free-energy change and the work generation through a four-process cycle, we define a work ratio as the work of actual engines relative to that of a so-called hygro-Carnot cycle going through reversible changes of volume and chemical energy. We propose an explanation why natural motile plants exhibit higher work ratios than common artificial hygroscopic actuators based on the time scales of soft actuation and the environmental humidity change. Our thermodynamic model can be extended to a range of soft engines driven by diffusion of stimulus, e.g., solvent, heat, and ions, into soft media.
- 26 October 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 18 (4) , 044061
Thermodynamics of Hygroresponsive Soft Engines: Cycle Analysis and Work Ratio
Soft materials that respond to external stimuli, such as moisture, heat, and light, can convert the environmental energy into mechanical motions, and thus can be considered engines. The energy-conversion process within the soft-materials-based engines is fundamentally different from that of conventional heat engines utilizing gaseous media, but has been rarely studied to date. Here we construct a theoretical framework to analyze the thermodynamic performance of humidity-responsive soft actuators, as a canonical model of soft engines, which operate in a similar manner to such motile plants as wild wheat seeds and pine cones. Considering the free-energy change and the work generation through a four-process cycle, we define a work ratio as the work of actual engines relative to that of a so-called hygro-Carnot cycle going through reversible changes of volume and chemical energy. We propose an explanation why natural motile plants exhibit higher work ratios than common artificial hygroscopic actuators based on the time scales of soft actuation and the environmental humidity change. Our thermodynamic model can be extended to a range of soft engines driven by diffusion of stimulus, e.g., solvent, heat, and ions, into soft media.
- Top Cited Papers
- 31 January 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 3 (14)
Hygrobot: A self-locomotive ratcheted actuator powered by environmental humidity
A hygroresponsive actuation system crawls on a moist surface using aligned nanofibers that quickly swell and shrink.
- 31 January 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 3 (14)
Top Cited PapersHygrobot: A self-locomotive ratcheted actuator powered by environmental humidity
A hygroresponsive actuation system crawls on a moist surface using aligned nanofibers that quickly swell and shrink.