Arianna Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arianna Lee has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Beomjune Shin
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
1 shared publication - Jimin Lee
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
1 shared publication JunHo Song
School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
1 shared publicationJuo Kim
School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
1 shared publication- Kyoungmin Min
School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
1 shared publication - Saewoong Oh
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
1 shared publication
Latest Publications
- Open Access
- 10 December 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (2) , 273-285
Capillary-driven, superhydrophilic microfluidic retainer for continuous salivary glucose monitoring
Salivary glucose monitoring provides a non-invasive alternative to blood-based diabetes tests; however, low analyte levels and unstable microfluidic wetting have hindered its translation. Here, we introduce a retainer-based microfluidic system that integrates a capillary-driven, superhydrophilic microchannel with a miniaturized three-electrode enzymatic sensor for continuous salivary glucose monitoring. This device maintains sustained hydrophilicity for at least 120 days without compromising flexibility or biocompatibility. The gold working electrode, functionalized with glucose oxidase immobilized in a carbon nanotube–chitosan matrix and a thin glutaraldehyde overlayer, offers sensitive and stable detection. The integrated sensor shows the chronoamperometric sensitivity of 15.48 μA mM-1 cm-2, and a limit of detection of < 42 μM. The in-vitro measurements using glucose-spiked artificial saliva show the reproduced postprandial profiles with rapid signal stabilization and high run-to-run repeatability over three cycles. Overall, this work captures the potential of the retainer-based microfluidic system as a practical pathway toward continuous, non-invasive, salivary glucose monitoring.
- 10 December 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (2) , 273-285
Open AccessCapillary-driven, superhydrophilic microfluidic retainer for continuous salivary glucose monitoring
Salivary glucose monitoring provides a non-invasive alternative to blood-based diabetes tests; however, low analyte levels and unstable microfluidic wetting have hindered its translation. Here, we introduce a retainer-based microfluidic system that integrates a capillary-driven, superhydrophilic microchannel with a miniaturized three-electrode enzymatic sensor for continuous salivary glucose monitoring. This device maintains sustained hydrophilicity for at least 120 days without compromising flexibility or biocompatibility. The gold working electrode, functionalized with glucose oxidase immobilized in a carbon nanotube–chitosan matrix and a thin glutaraldehyde overlayer, offers sensitive and stable detection. The integrated sensor shows the chronoamperometric sensitivity of 15.48 μA mM-1 cm-2, and a limit of detection of < 42 μM. The in-vitro measurements using glucose-spiked artificial saliva show the reproduced postprandial profiles with rapid signal stabilization and high run-to-run repeatability over three cycles. Overall, this work captures the potential of the retainer-based microfluidic system as a practical pathway toward continuous, non-invasive, salivary glucose monitoring.