Hitesh Gowda Bettaswamy Gowda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hitesh Gowda Bettaswamy Gowda has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ulrike Wallrabe
Department of Microsystems Engineering (IMTEK) Laboratory for Microactuators Albert‐Ludwigs‐Universität Freiburg Freiburg Germany
10 shared publications Matthias C. Wapler
Otto von Guericke University Magdeburg
2 shared publications- Matthias C. Wapler
University of Freiburg
2 shared publications Binal P. Bruno
Univ Freiburg, Dept Microsyst Engn IMTEK, Lab Microactuators, Freiburg, Germany
1 shared publication- Binal Poyyathuruthy Bruno
Laboratory for Microactuators, Albert-Ludwigs-Universitat Freiburg Institut fur Mikrosystemtechnik, Georges-Köhler-Allee 102, Freiburg, Baden-Württemberg, 79110, GERMANY
1 shared publication - Elisabetta Bodo
Department of Electrical, Computer and Biomedical Engineering, University of Pavia, 27100 Pavia, Italy
1 shared publication
Latest Publications
- 6 April 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 216
Humidity resistant triboelectric nanogenerators for wind energy harvesting: A review
- 6 April 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 216
Humidity resistant triboelectric nanogenerators for wind energy harvesting: A review
- 8 August 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (23) , 6282-6286
In-line refractive index measurement: a simple method based on image detection
We present a simple method to determine the refractive index of fluids that is suitable for real-time integrated measurements by imaging a collimated beam through a fluid volume and determining its diameter on a CMOS sensor. Our experimental results agree with the prediction of our analytical model, and the resulting refractive index agrees with the measurements obtained with a commercial refractometer with an RMS deviation of just ±0.003. This method requires only inexpensive components: a light source, two lenses, and a camera sensor; it is suitable for real-time monitoring, and it is essentially unlimited in the range of refractive indices.
- 8 August 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (23) , 6282-6286
In-line refractive index measurement: a simple method based on image detection
We present a simple method to determine the refractive index of fluids that is suitable for real-time integrated measurements by imaging a collimated beam through a fluid volume and determining its diameter on a CMOS sensor. Our experimental results agree with the prediction of our analytical model, and the resulting refractive index agrees with the measurements obtained with a commercial refractometer with an RMS deviation of just ±0.003. This method requires only inexpensive components: a light source, two lenses, and a camera sensor; it is suitable for real-time monitoring, and it is essentially unlimited in the range of refractive indices.
- 28 June 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (14) , 23393-23405
Higher order wavefront correction and axial scanning in a single fast and compact piezo-driven adaptive lens
We present a compact adaptive glass membrane lens for higher order wavefront correction and axial scanning, driven by integrated segmented piezoelectric actuators. The membrane can be deformed in a combination of rotational symmetry providing focus control of up to ± 6 m−1 and spherical aberration correction of up to 5 wavelengths and different discrete symmetries to correct higher order aberrations such as astigmatism, coma and trefoil by up to 10 wavelengths. Our design provides a large clear aperture of 12 mm at an outer diameter of the actuator of 18 mm, a thickness of 2 mm and a response time of less than 2 ms.
- 28 June 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (14) , 23393-23405
Higher order wavefront correction and axial scanning in a single fast and compact piezo-driven adaptive lens
We present a compact adaptive glass membrane lens for higher order wavefront correction and axial scanning, driven by integrated segmented piezoelectric actuators. The membrane can be deformed in a combination of rotational symmetry providing focus control of up to ± 6 m−1 and spherical aberration correction of up to 5 wavelengths and different discrete symmetries to correct higher order aberrations such as astigmatism, coma and trefoil by up to 10 wavelengths. Our design provides a large clear aperture of 12 mm at an outer diameter of the actuator of 18 mm, a thickness of 2 mm and a response time of less than 2 ms.
- 13 April 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (12) , 3072-3082
Reliability of tunable lenses: feedback sensors and the influence of temperature, orientation, and vibrations
We compare different aspects of the robustness to environmental conditions of two different types of piezo-actuated fluid-membrane lenses: a silicone membrane lens, where the piezo actuator indirectly deforms the flexible membrane through fluid displacement, and a glass membrane lens, where the piezo actuator directly deforms the stiff membrane. While both lenses operated reliably over the temperature range of 0°–75°C, there was a significant effect on their actuation characteristics, which can be well described through a simple model. The silicone lens in particular showed a variation in focal power of up to 0.1m−1∘C−1. We demonstrated that integrated pressure and temperature sensors can provide feedback for focal power, however, limited by the response time of the elastomers in the lenses, with polyurethane in the support structures of the glass membrane lens being more critical than the silicone. Studying the mechanical effects, the silicone membrane lens showed a gravity-induced coma and tilt, and a reduced imaging quality with the Strehl ratio decreasing from 0.89 to 0.31 at a vibration frequency of 100 Hz and an acceleration of 3g. The glass membrane lens was unaffected by gravity, and the Strehl ratio decreased from 0.92 to 0.73 at a vibration of 100 Hz, 3g. Overall, the stiffer glass membrane lens is more robust against environmental influences.
- 13 April 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (12) , 3072-3082
Reliability of tunable lenses: feedback sensors and the influence of temperature, orientation, and vibrations
We compare different aspects of the robustness to environmental conditions of two different types of piezo-actuated fluid-membrane lenses: a silicone membrane lens, where the piezo actuator indirectly deforms the flexible membrane through fluid displacement, and a glass membrane lens, where the piezo actuator directly deforms the stiff membrane. While both lenses operated reliably over the temperature range of 0°–75°C, there was a significant effect on their actuation characteristics, which can be well described through a simple model. The silicone lens in particular showed a variation in focal power of up to 0.1m−1∘C−1. We demonstrated that integrated pressure and temperature sensors can provide feedback for focal power, however, limited by the response time of the elastomers in the lenses, with polyurethane in the support structures of the glass membrane lens being more critical than the silicone. Studying the mechanical effects, the silicone membrane lens showed a gravity-induced coma and tilt, and a reduced imaging quality with the Strehl ratio decreasing from 0.89 to 0.31 at a vibration frequency of 100 Hz and an acceleration of 3g. The glass membrane lens was unaffected by gravity, and the Strehl ratio decreased from 0.92 to 0.73 at a vibration of 100 Hz, 3g. Overall, the stiffer glass membrane lens is more robust against environmental influences.
- 7 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 46528-46540
Tunable doublets: piezoelectric glass membrane lenses with an achromatic and spherical aberration control
We present two versions of tunable achromatic doublets based on each two piezoelectrically actuated glass membranes that create the surface of fluid volumes with different dispersions: a straightforward back-to-back and a more intricate stack of the fluid volumes. In both cases, we can control the chromatic focal shift and focal power independently by a suitable combination of actuation voltages on both active membranes. The doublets have a large aperture of 12 mm at an outer diameter of the actuator of 18 mm, an overall thickness of 3 mm and a short response time of around 0.5 ms and, in addition, provide spherical aberration correction. The two designs have an achromatic focal power range of ±2.2 m−1 and ±3.2 m−1 or, for the purpose of actively correcting chromatic errors, a chromatic focal shift at vanishing combined focal power of up to ±0.08 m−1 and ±0.12 m−1.
- 7 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 46528-46540
Tunable doublets: piezoelectric glass membrane lenses with an achromatic and spherical aberration control
We present two versions of tunable achromatic doublets based on each two piezoelectrically actuated glass membranes that create the surface of fluid volumes with different dispersions: a straightforward back-to-back and a more intricate stack of the fluid volumes. In both cases, we can control the chromatic focal shift and focal power independently by a suitable combination of actuation voltages on both active membranes. The doublets have a large aperture of 12 mm at an outer diameter of the actuator of 18 mm, an overall thickness of 3 mm and a short response time of around 0.5 ms and, in addition, provide spherical aberration correction. The two designs have an achromatic focal power range of ±2.2 m−1 and ±3.2 m−1 or, for the purpose of actively correcting chromatic errors, a chromatic focal shift at vanishing combined focal power of up to ±0.08 m−1 and ±0.12 m−1.
- Open Access
High-Flexibility Control of Structured Light with Combined Adaptive Optical Systems
Combining the specific advantages of high-resolution liquid-crystal-on-silicon spatial light modulators (LCoS-SLMs) and reflective or refractive micro-electro-mechanical systems (MEMS) presents new prospects for the generation of structured light fields. In particular, adaptive self-apodization schemes can significantly reduce diffraction by low-loss spatial filtering. The concept enables one to realize low-dispersion shaping of nondiffracting femtosecond wavepackets and to temporally switch, modulate or deflect spatially structured beams. Adaptive diffraction management by structured illumination is demonstrated for piezo-based and thermally actuated axicons, spiral phase plates (SPPs) and Fresnel bi-mirrors. Improved non-collinear autocorrelation with angular-tunable Fresnel-bi-mirrors via self-apodized illumination and phase contrast of an SLM is proposed. An extension of the recently introduced nondiffractive Talbot effect to a tunable configuration by combining an SLM and a fluid lens is reported. Experimental results for hexagonal as well as orthogonal array beams are presented.
Open AccessHigh-Flexibility Control of Structured Light with Combined Adaptive Optical Systems
Combining the specific advantages of high-resolution liquid-crystal-on-silicon spatial light modulators (LCoS-SLMs) and reflective or refractive micro-electro-mechanical systems (MEMS) presents new prospects for the generation of structured light fields. In particular, adaptive self-apodization schemes can significantly reduce diffraction by low-loss spatial filtering. The concept enables one to realize low-dispersion shaping of nondiffracting femtosecond wavepackets and to temporally switch, modulate or deflect spatially structured beams. Adaptive diffraction management by structured illumination is demonstrated for piezo-based and thermally actuated axicons, spiral phase plates (SPPs) and Fresnel bi-mirrors. Improved non-collinear autocorrelation with angular-tunable Fresnel-bi-mirrors via self-apodized illumination and phase contrast of an SLM is proposed. An extension of the recently introduced nondiffractive Talbot effect to a tunable configuration by combining an SLM and a fluid lens is reported. Experimental results for hexagonal as well as orthogonal array beams are presented.
- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 427-430
A One-Inch Aperture Piezoelectric Tunable Lens with Small Footprint
We present a novel approach to integrate the piezoelectric actuators in a tunable fluid-membrane lens. We achieved a large aperture of 2.5 cm and a small footprint of $3\times 3\times 0.6 \text{cm}^{3}$ , The actuators are fixed on the fluid chamber's sidewalls to displace the fluid towards the center and deform the flexible membrane. COMSOL Multiphysics® was used to simulate and optimize the lens design. The simulation resulted in a refractive power range of ± 2 dpt for a glass membrane lens and ± 5 dpt for a silicone membrane lens. The refractive power of the fabricated lenses was ± 0.9 dpt and ± 2.3 dpt, respectively.- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 427-430
A One-Inch Aperture Piezoelectric Tunable Lens with Small Footprint
We present a novel approach to integrate the piezoelectric actuators in a tunable fluid-membrane lens. We achieved a large aperture of 2.5 cm and a small footprint of $3\times 3\times 0.6 \text{cm}^{3}$ , The actuators are fixed on the fluid chamber's sidewalls to displace the fluid towards the center and deform the flexible membrane. COMSOL Multiphysics® was used to simulate and optimize the lens design. The simulation resulted in a refractive power range of ± 2 dpt for a glass membrane lens and ± 5 dpt for a silicone membrane lens. The refractive power of the fabricated lenses was ± 0.9 dpt and ± 2.3 dpt, respectively.- Open Access
Integrated Sensor System to Control the Temperature Effects and the Hysteresis on Adaptive Fluid-Membrane Piezoelectric Lenses
We present in this paper an integrated sensor system for closed-loop control of the temperature effects and the hysteresis on the refractive power of an adaptive fluid-membrane piezoelectric lens. The piezoelectric hysteresis and the fluid thermal expansion contribute to a nonlinear response of the lens refractive power defined as a function of the actuation electric field. Hence, a pressure sensor and a temperature sensor are integrated inside the lens to monitor and define the lens refractive power as a function of both the internal fluid pressure and the temperature, thus, allowing for the closed-loop control of the refractive power. The adaptive lens has a refractive power range varying from -16 m-1 to +17 m-1 at 25{\deg}C and from -15 m-1 to +28 m 1 at 75{\deg}C.
Open AccessIntegrated Sensor System to Control the Temperature Effects and the Hysteresis on Adaptive Fluid-Membrane Piezoelectric Lenses
We present in this paper an integrated sensor system for closed-loop control of the temperature effects and the hysteresis on the refractive power of an adaptive fluid-membrane piezoelectric lens. The piezoelectric hysteresis and the fluid thermal expansion contribute to a nonlinear response of the lens refractive power defined as a function of the actuation electric field. Hence, a pressure sensor and a temperature sensor are integrated inside the lens to monitor and define the lens refractive power as a function of both the internal fluid pressure and the temperature, thus, allowing for the closed-loop control of the refractive power. The adaptive lens has a refractive power range varying from -16 m-1 to +17 m-1 at 25{\deg}C and from -15 m-1 to +28 m 1 at 75{\deg}C.
- Open Access
- 20 November 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (12) , 797
Simulation of an Adaptive Fluid-Membrane Piezoelectric Lens
In this paper, we present a finite-element simulation of an adaptive piezoelectric fluid-membrane lens for which we modelled the fluid-structure interaction and resulting membrane deformation in COMSOL Multiphysics®. Our model shows the explicit coupling of the piezoelectric physics with the fluid dynamics physics to simulate the interaction between the piezoelectric and the fluid forces that contribute to the deformation of a flexible membrane in the adaptive lens. Furthermore, the simulation model is extended to describe the membrane deformation by additional fluid forces from the fluid thermal expansion. Subsequently, the simulation model is used to study the refractive power of the adaptive lens as a function of internal fluid pressure and analyze the effect of the fluid thermal expansion on the refractive power. Finally, the simulation results of the refractive power are compared to the experimental results at different actuation levels and temperatures validating the coupled COMSOL model very well. This is explicitly proven by explaining an observed positive drift of the refractive power at higher temperatures.
- 20 November 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (12) , 797
Open AccessSimulation of an Adaptive Fluid-Membrane Piezoelectric Lens
In this paper, we present a finite-element simulation of an adaptive piezoelectric fluid-membrane lens for which we modelled the fluid-structure interaction and resulting membrane deformation in COMSOL Multiphysics®. Our model shows the explicit coupling of the piezoelectric physics with the fluid dynamics physics to simulate the interaction between the piezoelectric and the fluid forces that contribute to the deformation of a flexible membrane in the adaptive lens. Furthermore, the simulation model is extended to describe the membrane deformation by additional fluid forces from the fluid thermal expansion. Subsequently, the simulation model is used to study the refractive power of the adaptive lens as a function of internal fluid pressure and analyze the effect of the fluid thermal expansion on the refractive power. Finally, the simulation results of the refractive power are compared to the experimental results at different actuation levels and temperatures validating the coupled COMSOL model very well. This is explicitly proven by explaining an observed positive drift of the refractive power at higher temperatures.
- Open Access
- 21 October 2019
- Published by MDPI AG in Preprints.org
Simulation of an Adaptive Fluid-Membrane Piezoelectric Lens
In this paper, we present a finite element simulation of an adaptive piezoelectric fluid-membrane lens modeled in COMSOL Multiphysics. The simulation couples the piezoelectric effect with the fluid dynamics to model the interaction between piezoelectric forces and fluid forces. Also, the simulation is extended to model the thermal expansion of the fluid. Finally, we compare the simulation and experimental results of the adaptive lens refractive power at different actuation levels and temperatures.
- 21 October 2019
- Published by MDPI AG in Preprints.org
Open AccessSimulation of an Adaptive Fluid-Membrane Piezoelectric Lens
In this paper, we present a finite element simulation of an adaptive piezoelectric fluid-membrane lens modeled in COMSOL Multiphysics. The simulation couples the piezoelectric effect with the fluid dynamics to model the interaction between piezoelectric forces and fluid forces. Also, the simulation is extended to model the thermal expansion of the fluid. Finally, we compare the simulation and experimental results of the adaptive lens refractive power at different actuation levels and temperatures.