Wei Liu
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Congjie Wang
Beijing Institute of Technology, 100081, China
2 shared publicationsFei Gao
State Key Laboratory of Operation and Control of Renewable Energy & Storage Systems, China Electric Power Research Institute. Beijing 100192, China
2 shared publications- Maosong Fan
State Key Laboratory of Operation and Control of Renewable Energy & Storage Systems, China Electric Power Research Institute. Beijing 100192, China
2 shared publications - Yanli Zhu
State Key Laboratory of Explosion Science and Safety Protection, Beijing Institute of Technology, Beijing, China
2 shared publications - Gehao Sheng
Shanghai Jiao Tong University
1 shared publication - Shuangshuang Tian
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan, China
1 shared publication
Latest Publications
- Open Access
- 24 March 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (4) , 121
Adsorption Properties of ZSM-5 Molecular Sieve for Perfluoroisobutyronitrile Mixtures and Its Fluorocarbon Decomposition Products
Perfluoroisobutyronitrile (C4F7N), an environment-friendly insulating gas, has excellent insulating properties and has the potential to be used in gas-insulated equipment when mixed with CO2. Selecting suitable adsorption materials to adsorb the decomposition products of the C4F7N mixture can ensure the safe and stable operation of the gas-insulated equipment and the personal safety of the operators in the electric power industry. The adsorption characteristics of the ZSM-5 molecular sieve on C4F7N and its five fluorocarbon decomposition products were investigated by adsorption experiments. The results show that the ZSM-5 molecular sieve has a certain adsorption effect on six fluorocarbon gases; the adsorption performance of C3F6 and C3F8 are the best, with an adsorption efficiency over 85%, while the concentration of CO2 and C4F7N is affected by the ZSM-5 molecular sieve. At the same time, the paper based on the Metropolis Monte Carlo simulation of Materials Studio software found that the ZSM-5 molecular sieve has the strongest adsorption effect on C4F7N molecules and the weakest adsorption effect on CO2 molecules. The stronger the polarity of the gas molecule, the more obvious the adsorption effect of molecular sieve structure on it. As a result, the ZSM-5 molecular sieve could be used in tail gas purification of insulated equipment, as well as to provide solutions for the development and production of protective equipment.
- 24 March 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (4) , 121
Open AccessAdsorption Properties of ZSM-5 Molecular Sieve for Perfluoroisobutyronitrile Mixtures and Its Fluorocarbon Decomposition Products
Perfluoroisobutyronitrile (C4F7N), an environment-friendly insulating gas, has excellent insulating properties and has the potential to be used in gas-insulated equipment when mixed with CO2. Selecting suitable adsorption materials to adsorb the decomposition products of the C4F7N mixture can ensure the safe and stable operation of the gas-insulated equipment and the personal safety of the operators in the electric power industry. The adsorption characteristics of the ZSM-5 molecular sieve on C4F7N and its five fluorocarbon decomposition products were investigated by adsorption experiments. The results show that the ZSM-5 molecular sieve has a certain adsorption effect on six fluorocarbon gases; the adsorption performance of C3F6 and C3F8 are the best, with an adsorption efficiency over 85%, while the concentration of CO2 and C4F7N is affected by the ZSM-5 molecular sieve. At the same time, the paper based on the Metropolis Monte Carlo simulation of Materials Studio software found that the ZSM-5 molecular sieve has the strongest adsorption effect on C4F7N molecules and the weakest adsorption effect on CO2 molecules. The stronger the polarity of the gas molecule, the more obvious the adsorption effect of molecular sieve structure on it. As a result, the ZSM-5 molecular sieve could be used in tail gas purification of insulated equipment, as well as to provide solutions for the development and production of protective equipment.
- Open Access
- 10 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 51277-51282
Simulation and Experiment of SF₆/N₂ Mixed Gas Distribution in High Vertical Drop GIL
Dielectric breakdown of a vertical Gas insulated transmission line (GIL) caused by demixing of the mixture of SF 6 /N 2 is studied by both theoretical simulation and the experimental measure. The mechanism and the threshhold of the demixing is addressed quantitatively. The potential risk of the segregation of the molecules by forming dimer or trimer under the high voltage is excluded by the quantum mechanics simulation in microscopic scale and the molecular simulation in mesoscopic scale. In macroscopic scale, the distribution of the mixture depending on the length of the tube is computed by the statistical physics quantitatively.
- 10 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 51277-51282
Open AccessSimulation and Experiment of SF₆/N₂ Mixed Gas Distribution in High Vertical Drop GIL
Dielectric breakdown of a vertical Gas insulated transmission line (GIL) caused by demixing of the mixture of SF 6 /N 2 is studied by both theoretical simulation and the experimental measure. The mechanism and the threshhold of the demixing is addressed quantitatively. The potential risk of the segregation of the molecules by forming dimer or trimer under the high voltage is excluded by the quantum mechanics simulation in microscopic scale and the molecular simulation in mesoscopic scale. In macroscopic scale, the distribution of the mixture depending on the length of the tube is computed by the statistical physics quantitatively.
- Open Access
- 1 January 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 631 (1) , 012114
Study on Temperature Change of LiFePO4/C Battery Thermal Runaway under Overcharge Condition
In this paper, thermal runaway test of lithium iron phosphate battery (LiFePO4/C) under overcharge condition was carried out. The temperature and its rise rate of three types of LiFePO4/C batteries (25 Ah, 60 Ah and 200 Ah) in the process of thermal runaway were compared and analyzed. The research shows that under the condition of 1C-rate overcharge, the starting temperature of the LiFePO4/C battery thermal runaway is about 116 °C - 131 °C, and its temperature rise rate of thermal runaway is about 3.01 °C/s - 5.82 °C/s. The highest temperature reached by thermal runaway has nothing to do with the battery capacity.
- 1 January 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 631 (1) , 012114
Open AccessStudy on Temperature Change of LiFePO4/C Battery Thermal Runaway under Overcharge Condition
In this paper, thermal runaway test of lithium iron phosphate battery (LiFePO4/C) under overcharge condition was carried out. The temperature and its rise rate of three types of LiFePO4/C batteries (25 Ah, 60 Ah and 200 Ah) in the process of thermal runaway were compared and analyzed. The research shows that under the condition of 1C-rate overcharge, the starting temperature of the LiFePO4/C battery thermal runaway is about 116 °C - 131 °C, and its temperature rise rate of thermal runaway is about 3.01 °C/s - 5.82 °C/s. The highest temperature reached by thermal runaway has nothing to do with the battery capacity.
- Open Access
- 1 January 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 631 (1) , 012105
Study on Thermal Runaway Process of LiFePO4/C Batteries
The LiFePOVC battery has been widely used in many fields, and its safety problems are gradually attracting widespread concern. In this paper, two kinds of LiFePO4/C batteries with 25 Ah and 200 Ah were taken as research objects. The thermal runaway phenomena of two batteries were analyzed, and the difference of thermal runaway phenomena between two batteries were compared. The results show that the safety valve of the 200 Ah battery ruptures earlier and the thermal runaway occurs earlier under the same overcharge rate. The work provides a reference for the protection design of LiFePO4/C batteries.
- 1 January 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 631 (1) , 012105
Open AccessStudy on Thermal Runaway Process of LiFePO4/C Batteries
The LiFePOVC battery has been widely used in many fields, and its safety problems are gradually attracting widespread concern. In this paper, two kinds of LiFePO4/C batteries with 25 Ah and 200 Ah were taken as research objects. The thermal runaway phenomena of two batteries were analyzed, and the difference of thermal runaway phenomena between two batteries were compared. The results show that the safety valve of the 200 Ah battery ruptures earlier and the thermal runaway occurs earlier under the same overcharge rate. The work provides a reference for the protection design of LiFePO4/C batteries.
- Open Access
A Novel Partial Discharge Detection Method Based on the Photoelectric Fusion Pattern in GIL
Optical detection and ultrahigh frequency (UHF) detection are two significant methods of partial discharge (PD) detection in the gas-insulated transmission lines (GIL), however, there is a phenomenon of signals loss when using two types of detections to monitor PD signals of different defects, such as needle defect and free particle defect. This makes the optical and UHF signals not correspond strictly to the actual PD signals, and therefore the characteristic information of optical PD patterns and UHF PD patterns is incomplete which reduces the accuracy of the pattern recognition. Therefore, an image fusion algorithm based on improved non-subsampled contourlet transform (NSCT) is proposed in this study. The optical pattern is fused with the UHF pattern to achieve the complementarity of the two detection methods, avoiding the PD signals loss of different defects. By constructing the experimental platform of optical-UHF integrated detection for GIL, phase-resolved partial discharge (PRPD) patterns of three defects were obtained. After that, the image fusion algorithm based on the local entropy and the phase congruency was used to produce the photoelectric fusion PD pattern. Before the pattern recognition, 28 characteristic parameters are extracted from the photoelectric fusion pattern, and then the dimension of the feature space is reduced to eight by the principal component analysis. Finally, three kinds of classifiers, including the linear discriminant analysis (LDA), support vector machine (SVM), and k-nearest neighbor (KNN), are used for the pattern recognition. The results show that the recognition rate of all the photoelectric fusion pattern under different classifiers is higher than that of optical and UHF patterns, up to the maximum of 95%. Moreover, the photoelectric fusion pattern not only greatly improves the recognition rate of the needle defect and the free particle defect, but the recognition accuracy of the floating defect is also slightly improved.
Open AccessA Novel Partial Discharge Detection Method Based on the Photoelectric Fusion Pattern in GIL
Optical detection and ultrahigh frequency (UHF) detection are two significant methods of partial discharge (PD) detection in the gas-insulated transmission lines (GIL), however, there is a phenomenon of signals loss when using two types of detections to monitor PD signals of different defects, such as needle defect and free particle defect. This makes the optical and UHF signals not correspond strictly to the actual PD signals, and therefore the characteristic information of optical PD patterns and UHF PD patterns is incomplete which reduces the accuracy of the pattern recognition. Therefore, an image fusion algorithm based on improved non-subsampled contourlet transform (NSCT) is proposed in this study. The optical pattern is fused with the UHF pattern to achieve the complementarity of the two detection methods, avoiding the PD signals loss of different defects. By constructing the experimental platform of optical-UHF integrated detection for GIL, phase-resolved partial discharge (PRPD) patterns of three defects were obtained. After that, the image fusion algorithm based on the local entropy and the phase congruency was used to produce the photoelectric fusion PD pattern. Before the pattern recognition, 28 characteristic parameters are extracted from the photoelectric fusion pattern, and then the dimension of the feature space is reduced to eight by the principal component analysis. Finally, three kinds of classifiers, including the linear discriminant analysis (LDA), support vector machine (SVM), and k-nearest neighbor (KNN), are used for the pattern recognition. The results show that the recognition rate of all the photoelectric fusion pattern under different classifiers is higher than that of optical and UHF patterns, up to the maximum of 95%. Moreover, the photoelectric fusion pattern not only greatly improves the recognition rate of the needle defect and the free particle defect, but the recognition accuracy of the floating defect is also slightly improved.