Søren Rytter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Søren Rytter has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Maiken Stilling
Aarhus University Hospital
4 shared publications - Anders Odgaard
Department of Orthopaedic Surgery, Rigshospitalet, Copenhagen, Denmark
2 shared publications Frank Madsen
Department of Orthopaedic Surgery, Rigshospitalet, Copenhagen University Hospital, Blegdamsvej 9, 2100 Copenhagen, Denmark
2 shared publications- Torben Bæk Hansen
Department of Orthopedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
2 shared publications - Alexander D. Liddle
MSk Lab - Imperial College London, Department of Surgery & Cancer, Sir Michael Uren Hub, 86 Wood Ln, London W12 0BZ
1 shared publication Bjorn Gotlieb Jensen
Reg Hosp Vejle, Dept Orthopaed Surg, Lillebaelt Hosp, Vejle, Denmark
1 shared publication
Latest Publications
- Open Access
- 20 November 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 17, 101037
Equivocal physical activity outcomes 10 Years after patellofemoral vs total knee replacement: Follow-up of a previously reported randomized controlled trial in isolated patellofemoral joint osteoarthritis
- 20 November 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 17, 101037
Open AccessEquivocal physical activity outcomes 10 Years after patellofemoral vs total knee replacement: Follow-up of a previously reported randomized controlled trial in isolated patellofemoral joint osteoarthritis
- Open Access
- 9 May 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 13 (5) , 226-236
Stable polyethylene inlay fixation and low polyethylene wear rate in fixed-bearing total knee arthroplasty at five to six years’ follow-up
Aims: Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.Methods: A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.Results: At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041).Conclusion: The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear.Cite this article: Bone Joint Res 2024;13(5):226–236.
- 9 May 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 13 (5) , 226-236
Open AccessStable polyethylene inlay fixation and low polyethylene wear rate in fixed-bearing total knee arthroplasty at five to six years’ follow-up
Aims: Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.Methods: A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.Results: At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041).Conclusion: The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear.Cite this article: Bone Joint Res 2024;13(5):226–236.
- 1 September 2019
- Vol. 66 (9)
A prospective study of day of surgery discharge in 368 consecutive patients with unicompartmental knee replacement
INTRODUCTION: There has been an increased focus on fast-track (FT) programmes and the potential to convert unicompartmental knee replacement (UKR) from short-term admission to outpatient surgery. However, relatively few studies have been presented and with differences in selection criteria and completion rates. The purpose of this study was to describe patient selection and completion rates in a patient group undergoing UKR in two high-volume FT knee surgery clinics. METHODS: All consecutive patients (n = 368) referred to and selected for UKR were, screened for eligibility for outpatient surgery with discharge on the day of surgery (DOS). Reasons why the patients were not discharged were recorded in patients not completing the or it patient pathway, and readmissions and complications were recorded until three months postoperatively. RESULTS: Among all referred and screened patients, 69% were considered eligible for outpatient surgery. DOS discharge occurred in 59% of the operated patients and in 37% of all referred and screened patients. Main reasons for why patients were not discharged were active wound drainage and lack of mobilisation due to pain, nausea and vomiting. Two patients were readmitted during the first 24 hours due to wound drainage. One patient had a lung embolus and one patient an acute myocardial infarction during the follow-up period. CONCLUSIONS: This study illustrates that not all patients in a consecutive patient group for UKR were feasible for outpatient surgery. Further studies should focus on optimising pain treatment and reducing postoperative nausea.
- 1 September 2019
- Vol. 66 (9)
A prospective study of day of surgery discharge in 368 consecutive patients with unicompartmental knee replacement
INTRODUCTION: There has been an increased focus on fast-track (FT) programmes and the potential to convert unicompartmental knee replacement (UKR) from short-term admission to outpatient surgery. However, relatively few studies have been presented and with differences in selection criteria and completion rates. The purpose of this study was to describe patient selection and completion rates in a patient group undergoing UKR in two high-volume FT knee surgery clinics. METHODS: All consecutive patients (n = 368) referred to and selected for UKR were, screened for eligibility for outpatient surgery with discharge on the day of surgery (DOS). Reasons why the patients were not discharged were recorded in patients not completing the or it patient pathway, and readmissions and complications were recorded until three months postoperatively. RESULTS: Among all referred and screened patients, 69% were considered eligible for outpatient surgery. DOS discharge occurred in 59% of the operated patients and in 37% of all referred and screened patients. Main reasons for why patients were not discharged were active wound drainage and lack of mobilisation due to pain, nausea and vomiting. Two patients were readmitted during the first 24 hours due to wound drainage. One patient had a lung embolus and one patient an acute myocardial infarction during the follow-up period. CONCLUSIONS: This study illustrates that not all patients in a consecutive patient group for UKR were feasible for outpatient surgery. Further studies should focus on optimising pain treatment and reducing postoperative nausea.
- 19 November 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (7) , 1069-1077
The lateral joint space width can be measured reliably with Telos valgus stress radiography in medial knee osteoarthritis
Objective To examine the reproducibility of valgus stress radiographs with the Telos stress device for assessment of lateral compartment degenerative changes in patients with medial osteoarthritis of the knee. Materials and methods A prospective reliability study was performed. Seventy-nine patients (80 knees) were included, and standardized valgus stress radiographs were obtained using the Telos stress device. Osteophytes and joint space narrowing (JSN) were graded using the OARSI (Osteoarthritis Research Society International) classification, and the joint space width (JSW) was measured in millimeters. Reproducibility was determined as intra-and inter-rater reliability and test–retest reliability. Weighted kappa was used to determine the reliability of osteophyte and JSN grading, and the intra-class correlation coefficient for JSW. Results Grading of osteophytes had an intra- and inter-rater reliability ranging from 0.40 to 0.83 on the medial side and ranging from 0.39 to 0.87 on the lateral side. Grading of medial JSN had an intra- and inter-rater reliability ranging from 0.62 to 0.84, and grading of lateral JSN had an intra- and inter-rater reliability ranging from 0.32 to 0.65. Intra- and inter-rater reliability of JSW ranged from 0.84 to 0.98 on the medial side, and from 0.59 to 0.89 on the lateral side. Test–retest reliability of JSW of the medial and lateral side ranged from 0.69 to 0.92. Conclusions Standardized valgus stress radiographs taken with the Telos stress device are a reliable supplement in the assessment of medial OA of the knee. Evaluation of the lateral compartment on valgus stress radiographs is most reliable with measurement of the lateral JSW.
- 19 November 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (7) , 1069-1077
The lateral joint space width can be measured reliably with Telos valgus stress radiography in medial knee osteoarthritis
Objective To examine the reproducibility of valgus stress radiographs with the Telos stress device for assessment of lateral compartment degenerative changes in patients with medial osteoarthritis of the knee. Materials and methods A prospective reliability study was performed. Seventy-nine patients (80 knees) were included, and standardized valgus stress radiographs were obtained using the Telos stress device. Osteophytes and joint space narrowing (JSN) were graded using the OARSI (Osteoarthritis Research Society International) classification, and the joint space width (JSW) was measured in millimeters. Reproducibility was determined as intra-and inter-rater reliability and test–retest reliability. Weighted kappa was used to determine the reliability of osteophyte and JSN grading, and the intra-class correlation coefficient for JSW. Results Grading of osteophytes had an intra- and inter-rater reliability ranging from 0.40 to 0.83 on the medial side and ranging from 0.39 to 0.87 on the lateral side. Grading of medial JSN had an intra- and inter-rater reliability ranging from 0.62 to 0.84, and grading of lateral JSN had an intra- and inter-rater reliability ranging from 0.32 to 0.65. Intra- and inter-rater reliability of JSW ranged from 0.84 to 0.98 on the medial side, and from 0.59 to 0.89 on the lateral side. Test–retest reliability of JSW of the medial and lateral side ranged from 0.69 to 0.92. Conclusions Standardized valgus stress radiographs taken with the Telos stress device are a reliable supplement in the assessment of medial OA of the knee. Evaluation of the lateral compartment on valgus stress radiographs is most reliable with measurement of the lateral JSW.