Fengze Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fengze Tan has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Changyuan Yu
The Hong Kong Polytechnic University
13 shared publications - Chao Lu
The Hong Kong Polytechnic University
4 shared publications Jiajing Tu
Photonics Research Center, Department of Electronic and Information Engineering, The Hong Kong Polytechnic University, Hong Kong, China
4 shared publicationsGuifang Li
The College of Precision Instruments and Opto-electronic Engineering, Tianjin University, Tianjin, China
3 shared publicationsJian Zhao
The College of Precision Instruments and Opto-electronic Engineering, Tianjin University, Tianjin, China
3 shared publications- Shuyang Chen
Photonics Research Institute, Department of Electrical and Electronic Engineering, Hong Kong Polytechnic University, Hong Kong
3 shared publications
Latest Publications
- 5 April 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (8) , 13121-13133
Deep learning-based ballistocardiography reconstruction algorithm on the optical fiber sensor
Ballistocardiography (BCG) is a vibration signal related to cardiac activity, which can be obtained in a non-invasive way by optical fiber sensors. In this paper, we propose a modified generative adversarial network (GAN) to reconstruct BCG signals by solving signal fading problems in a Mach-Zehnder interferometer (MZI). Based on this algorithm, additional modulators and demodulators are not needed in the MZI, which reduces the cost and hardware complexity. The correlation between reconstructed BCG and reference BCG is 0.952 in test data. To further test the model performance, we collect special BCG signals including sinus arrhythmia data and post-exercise cardiac activities data, and analyze the reconstructed results. In conclusion, a BCG reconstruction algorithm is presented to solve the signal fading problem in the optical fiber interferometer innovatively, which greatly simplifies the BCG monitoring system.
- 5 April 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (8) , 13121-13133
Deep learning-based ballistocardiography reconstruction algorithm on the optical fiber sensor
Ballistocardiography (BCG) is a vibration signal related to cardiac activity, which can be obtained in a non-invasive way by optical fiber sensors. In this paper, we propose a modified generative adversarial network (GAN) to reconstruct BCG signals by solving signal fading problems in a Mach-Zehnder interferometer (MZI). Based on this algorithm, additional modulators and demodulators are not needed in the MZI, which reduces the cost and hardware complexity. The correlation between reconstructed BCG and reference BCG is 0.952 in test data. To further test the model performance, we collect special BCG signals including sinus arrhythmia data and post-exercise cardiac activities data, and analyze the reconstructed results. In conclusion, a BCG reconstruction algorithm is presented to solve the signal fading problem in the optical fiber interferometer innovatively, which greatly simplifies the BCG monitoring system.
- Open Access
Few-Mode Fiber Characterization System Based on the Spatially and Spectrally Imaging Technique
With the widespread use of few-mode fibers, mode characteristics testing becomes essential. In this paper, current few-mode fiber testing techniques are discussed, and the S2 imaging technique is chosen and demonstrated to be capable of few-mode fiber characterization in principle. As a result, the few-mode fiber characterization system with the S2 imaging technique is built and used to obtain accurate mode dispersion of two-mode fibers (a commonly used few-mode fiber) of different lengths. Then, various filters are applied to extract the fundamental and high-order modes to acquire mode coupling components (discrete and distributed mode coupling). The proposed system spectrally characterizes the few-mode fiber by resolving the interference information from the superimposed optical field spatially and has a simple structure and easy operation, which will provide parameter guidance for FMF designing and the FMF sensing experiment optimizing.
Open AccessFew-Mode Fiber Characterization System Based on the Spatially and Spectrally Imaging Technique
With the widespread use of few-mode fibers, mode characteristics testing becomes essential. In this paper, current few-mode fiber testing techniques are discussed, and the S2 imaging technique is chosen and demonstrated to be capable of few-mode fiber characterization in principle. As a result, the few-mode fiber characterization system with the S2 imaging technique is built and used to obtain accurate mode dispersion of two-mode fibers (a commonly used few-mode fiber) of different lengths. Then, various filters are applied to extract the fundamental and high-order modes to acquire mode coupling components (discrete and distributed mode coupling). The proposed system spectrally characterizes the few-mode fiber by resolving the interference information from the superimposed optical field spatially and has a simple structure and easy operation, which will provide parameter guidance for FMF designing and the FMF sensing experiment optimizing.
- Open Access
Vital Signs Monitoring Based on Interferometric Fiber Optic Sensors
Due to the improvement of living standards, people’s attention to health has gradually increased. More and more people are willing to spend money and time on health management. This article reviews work on the vital signs monitoring system based on fiber optic interferometers, including the design of sensor structures, signal demodulation methods and data analysis. After a large number of trials, the system can achieve long-term stable heart rate (HR), respiration rate (RR) and body temperature monitoring, and the collected data can be used for health analysis. Due to the high sensitivity, low cost, and light weight of the interferometric fiber optic sensor, it can be integrated under a mattress or a cushion, which is very suitable for daily use. The system has great application prospects in the field of healthcare.
Open AccessVital Signs Monitoring Based on Interferometric Fiber Optic Sensors
Due to the improvement of living standards, people’s attention to health has gradually increased. More and more people are willing to spend money and time on health management. This article reviews work on the vital signs monitoring system based on fiber optic interferometers, including the design of sensor structures, signal demodulation methods and data analysis. After a large number of trials, the system can achieve long-term stable heart rate (HR), respiration rate (RR) and body temperature monitoring, and the collected data can be used for health analysis. Due to the high sensitivity, low cost, and light weight of the interferometric fiber optic sensor, it can be integrated under a mattress or a cushion, which is very suitable for daily use. The system has great application prospects in the field of healthcare.
- 17 November 2020
- Published by Optica Publishing Group in Optical Materials Express
- Vol. 10 (12) , 3235-3244
Influence of liquid nitrogen cooling on the spectral performance of BAC-P in bismuth-doped phosphosilicate fibers under liquid nitrogen temperature
The first results of the liquid nitrogen cooling effect on the spectral properties of a phosphor-related bismuth active center (BAC-P) have been presented. It is found that the small-signal absorption bands of BACs are mildly affected at liquid nitrogen temperature (LNT, 77 K), while the unsaturable absorption level is lowered moderately. Meanwhile, noticeable shape changes of luminescence spectra and enhanced luminescence intensity (∼ twice) of BAC bands were revealed at LNT upon excitation at 830 or 980 nm, which is contributed by the notable growth of BAC-P. In addition, the influence of cooling on the on-off gain performance of BACs is also explored. Furthermore, the laser-induced effect on the luminescence of BAC-P upon cooling at LNT is also investigated, revealing a noticeable increase (∼10%) instead of photobleaching. These experimental results bring new insights into the temperature-related spectral properties of BACs and provide an effective way for tuning the luminescence scheme for Bi-doped fibers by cryogenics for the desired spectral range 1.26-1.36 μm.
- 17 November 2020
- Published by Optica Publishing Group in Optical Materials Express
- Vol. 10 (12) , 3235-3244
Influence of liquid nitrogen cooling on the spectral performance of BAC-P in bismuth-doped phosphosilicate fibers under liquid nitrogen temperature
The first results of the liquid nitrogen cooling effect on the spectral properties of a phosphor-related bismuth active center (BAC-P) have been presented. It is found that the small-signal absorption bands of BACs are mildly affected at liquid nitrogen temperature (LNT, 77 K), while the unsaturable absorption level is lowered moderately. Meanwhile, noticeable shape changes of luminescence spectra and enhanced luminescence intensity (∼ twice) of BAC bands were revealed at LNT upon excitation at 830 or 980 nm, which is contributed by the notable growth of BAC-P. In addition, the influence of cooling on the on-off gain performance of BACs is also explored. Furthermore, the laser-induced effect on the luminescence of BAC-P upon cooling at LNT is also investigated, revealing a noticeable increase (∼10%) instead of photobleaching. These experimental results bring new insights into the temperature-related spectral properties of BACs and provide an effective way for tuning the luminescence scheme for Bi-doped fibers by cryogenics for the desired spectral range 1.26-1.36 μm.
- Open Access
- 4 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Investigation on Smart Cushion Based on SFS Structure and its Application in Physiological and Activity Monitoring
A smart cushion based on SFS (single-mode-few-mode-single-mode) structure is proposed and experimentally demonstrated, which can be applied in physiological and activity states monitoring simultaneously. The sensing unit embedded in a common cushion is designed as a sandwich structure, consisting of a piece of fiberglass mesh, a SFS structure layer and a polyvinyl chloride (PVC) layer thus the sensitivity can be significantly enhanced. With off-line processing and analyzing of the raw signals collected from the cushion system, the heartbeat rate (HR) and respiratory rate (RR) can be obtained with the maximum error of 1 bpm and the activity states on the cushion can be clearly distinguished within the accuracy of one second. Such a smart cushion has the advantages of low cost, compact structure and high comfort, especially suitable for office workers and the elderly in nursing homes.
- 4 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Open AccessInvestigation on Smart Cushion Based on SFS Structure and its Application in Physiological and Activity Monitoring
A smart cushion based on SFS (single-mode-few-mode-single-mode) structure is proposed and experimentally demonstrated, which can be applied in physiological and activity states monitoring simultaneously. The sensing unit embedded in a common cushion is designed as a sandwich structure, consisting of a piece of fiberglass mesh, a SFS structure layer and a polyvinyl chloride (PVC) layer thus the sensitivity can be significantly enhanced. With off-line processing and analyzing of the raw signals collected from the cushion system, the heartbeat rate (HR) and respiratory rate (RR) can be obtained with the maximum error of 1 bpm and the activity states on the cushion can be clearly distinguished within the accuracy of one second. Such a smart cushion has the advantages of low cost, compact structure and high comfort, especially suitable for office workers and the elderly in nursing homes.
- 21 September 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (19) , 5389-5392
Photo-induced bleaching and thermally stimulated recovery of BAC-P in Bi-doped phosphosilicate fibers
The first results of the study on photobleaching and thermally induced recovery in Bi-doped phosphosilicate fiber have been presented. It was revealed that the rate of bleaching of phosphor-related Bi active center (BAC-P) becomes slower with the decrease of photon energy. The quadratic dependence of the bleaching rate of BAC-P on laser power is obtained under 532 nm laser irradiation. The effect of temperature on the bleaching dynamics of BAC-P is also investigated under 532 nm radiation, suggesting a thermally aggravated bleaching process upon heating at certain temperatures ( ≥ 300 ∘ C ). Furthermore, the thermal recovery of bleached Bi-doped silica-based fiber (BDF) is investigated and a 13% increase of luminescence is achieved upon thermal quenching for 5 min at 400ºC. The underlying mechanism of photobleaching and thermo-stimulated recovery process of BAC-P is also discussed.
- 21 September 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (19) , 5389-5392
Photo-induced bleaching and thermally stimulated recovery of BAC-P in Bi-doped phosphosilicate fibers
The first results of the study on photobleaching and thermally induced recovery in Bi-doped phosphosilicate fiber have been presented. It was revealed that the rate of bleaching of phosphor-related Bi active center (BAC-P) becomes slower with the decrease of photon energy. The quadratic dependence of the bleaching rate of BAC-P on laser power is obtained under 532 nm laser irradiation. The effect of temperature on the bleaching dynamics of BAC-P is also investigated under 532 nm radiation, suggesting a thermally aggravated bleaching process upon heating at certain temperatures ( ≥ 300 ∘ C ). Furthermore, the thermal recovery of bleached Bi-doped silica-based fiber (BDF) is investigated and a 13% increase of luminescence is achieved upon thermal quenching for 5 min at 400ºC. The underlying mechanism of photobleaching and thermo-stimulated recovery process of BAC-P is also discussed.
- 8 September 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (10) , 5458-5469
Ballistocardiography monitoring system based on optical fiber interferometer aided with heartbeat segmentation algorithm
An optical fiber interferometer-based ballistocardiography (BCG) monitoring system aided with the IJK complex detection algorithm is proposed in this paper. A new phase modulation method based on a moving-coil transducer is developed to address the problem of signal fading in the optical fiber interferometer and keep the system in quadrature by the closed loop controller. As a result, a stable BCG signal without baseline drift can be obtained. This BCG monitor based on optical fiber interferometer using phase modulation method owns the advantages of compact, low-cost, portable, and user-friendly. In addition, an end-to-end modified U-net is developed to conduct pixel-wise classification in the BCG signal. This network can achieve high accuracy and shows its capability to segment IJK complex and body movement in the BCG signal. In conclusion, the proposed BCG monitoring system with IJK complex segmentation algorithm is potential and promising in healthcare applications.
- 8 September 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (10) , 5458-5469
Ballistocardiography monitoring system based on optical fiber interferometer aided with heartbeat segmentation algorithm
An optical fiber interferometer-based ballistocardiography (BCG) monitoring system aided with the IJK complex detection algorithm is proposed in this paper. A new phase modulation method based on a moving-coil transducer is developed to address the problem of signal fading in the optical fiber interferometer and keep the system in quadrature by the closed loop controller. As a result, a stable BCG signal without baseline drift can be obtained. This BCG monitor based on optical fiber interferometer using phase modulation method owns the advantages of compact, low-cost, portable, and user-friendly. In addition, an end-to-end modified U-net is developed to conduct pixel-wise classification in the BCG signal. This network can achieve high accuracy and shows its capability to segment IJK complex and body movement in the BCG signal. In conclusion, the proposed BCG monitoring system with IJK complex segmentation algorithm is potential and promising in healthcare applications.
- 29 October 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (11) , 5940-5952
Non-invasive human vital signs monitoring based on twin-core optical fiber sensors
Twin-core fiber (TCF)-based sensor was proposed for non-invasive vital sign monitoring, including respiration and heartbeat. The TCF was homemade and the corresponding sensor was fabricated by sandwiching single-mode fiber (SMF) on both ends. The offset distance between SMF and TCF was optimized while the length of TCF was identified from preliminary vital sign measurement results. Then, the TCF-based sensor was attached under a mattress to realize non-invasive vital sign monitoring. Both respiration and heartbeat signal can be obtained simultaneously, which is consistent with the reference signals. For further application, post-exercise physiological activitity characterization were realized based on this vital sign monitoring system. In discussion, mode coupling in TCF was analyzed and utilized for curvature sensing with achieved sensitivity as high as 18 nm/m−1, which supported its excellent performance for vital signs monitoring. In conclusion, the TCF-based vital signs monitors can be a promising candidate for healthcare and biomedical applications.
- 29 October 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (11) , 5940-5952
Non-invasive human vital signs monitoring based on twin-core optical fiber sensors
Twin-core fiber (TCF)-based sensor was proposed for non-invasive vital sign monitoring, including respiration and heartbeat. The TCF was homemade and the corresponding sensor was fabricated by sandwiching single-mode fiber (SMF) on both ends. The offset distance between SMF and TCF was optimized while the length of TCF was identified from preliminary vital sign measurement results. Then, the TCF-based sensor was attached under a mattress to realize non-invasive vital sign monitoring. Both respiration and heartbeat signal can be obtained simultaneously, which is consistent with the reference signals. For further application, post-exercise physiological activitity characterization were realized based on this vital sign monitoring system. In discussion, mode coupling in TCF was analyzed and utilized for curvature sensing with achieved sensitivity as high as 18 nm/m−1, which supported its excellent performance for vital signs monitoring. In conclusion, the TCF-based vital signs monitors can be a promising candidate for healthcare and biomedical applications.
- Open Access
- 24 July 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (16) , 19835-19844
Torsion sensor based on inter-core mode coupling in seven-core fiber
We proposed a novel torsion sensor based on inter-core mode coupling in seven-core fiber (SCF). The torsion sensor is fabricated by tapering a commercially available SCF spliced with two single mode fibers. Waist diameter and length of the taper structure were experimentally optimized to achieve good transmission spectrum. Based on this structure, the torsion measurement was conducted, and the experimental results demonstrated that the transmission spectrum shows a red shift with the fiber twist. The torsion sensitivity increases with the twisting angle, which can achieve as high as 1.00 nm/°. The direction of wavelength shift was observed to be opposite when twisting the tapered SCF in clockwise and counter-clockwise direction, demonstrating its capability to discriminate the rotation orientation. Moreover, all the measurements were repeated in attempts to confirm its stable performance as well as high accuracy. Mode coupling dynamics and theory of optical anisotropy in twisted fiber are adopted to discuss the sensitivity performance, which agrees well with experimental results. The novel torsion sensor could provide a promising candidate for the applications requiring accurate rotation.
- 24 July 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (16) , 19835-19844
Open AccessTorsion sensor based on inter-core mode coupling in seven-core fiber
We proposed a novel torsion sensor based on inter-core mode coupling in seven-core fiber (SCF). The torsion sensor is fabricated by tapering a commercially available SCF spliced with two single mode fibers. Waist diameter and length of the taper structure were experimentally optimized to achieve good transmission spectrum. Based on this structure, the torsion measurement was conducted, and the experimental results demonstrated that the transmission spectrum shows a red shift with the fiber twist. The torsion sensitivity increases with the twisting angle, which can achieve as high as 1.00 nm/°. The direction of wavelength shift was observed to be opposite when twisting the tapered SCF in clockwise and counter-clockwise direction, demonstrating its capability to discriminate the rotation orientation. Moreover, all the measurements were repeated in attempts to confirm its stable performance as well as high accuracy. Mode coupling dynamics and theory of optical anisotropy in twisted fiber are adopted to discuss the sensitivity performance, which agrees well with experimental results. The novel torsion sensor could provide a promising candidate for the applications requiring accurate rotation.
- 1 January 2018
- Published by Optica Publishing Group
- p. W1K.6
Stable Torsion Sensor with Tunable Sensitivity and Rotation Direction Discrimination Based on a tapered Trench-Assisted Multi Core Fiber
A tapered Trench-Assisted Multi Core Fiber (TA-MCF) is firstly proposed and experimentally demonstrated for torsion sensing. The rotation direction can be discriminated and the torsion sensitivity is tunable up to 1.1 nm/°.
- 1 January 2018
- Published by Optica Publishing Group
- p. W1K.6
Stable Torsion Sensor with Tunable Sensitivity and Rotation Direction Discrimination Based on a tapered Trench-Assisted Multi Core Fiber
A tapered Trench-Assisted Multi Core Fiber (TA-MCF) is firstly proposed and experimentally demonstrated for torsion sensing. The rotation direction can be discriminated and the torsion sensitivity is tunable up to 1.1 nm/°.