Marcos Aurélio Bomfim da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcos Aurélio Bomfim da Silva has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Aline Barbirato Fardin
Department of Restorative Dentistry, Alagoas Federal University (UFAL), Av Lourival Melo Mota, s/n, Tabuleiro do Martins, 57072-970, Maceió, Alagoas, Brazil
1 shared publication- Josealdo Tonholo
Universidade Federal de Alagoas
1 shared publication José Ginaldo da Silva Júnior
Institute of Chemistry and Biotechnology, Alagoas Federal University (UFAL), Av Lourival Melo Mota, s/n, Tabuleiro do Martins, 57072-970, Maceió, Alagoas, Brazil
1 shared publicationJosé Ivo Limeira dos Reis
Department of Restorative Dentistry, Alagoas Federal University (UFAL), Av Lourival Melo Mota, s/n, Tabuleiro do Martins, 57072-970, Maceió, Alagoas, Brazil
1 shared publicationLucineide de Melo Santos
Department of Restorative Dentistry, Alagoas Federal University (UFAL), Av Lourival Melo Mota, s/n, Tabuleiro do Martins, 57072-970, Maceió, Alagoas, Brazil
1 shared publicationMarcelo Ferraz Mesquita
DDS, MSc, PhD, Professor of Prosthodontics, Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 October 2012
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 20 (5) , 588-593
Linear dimensional change, compressive strength and detail reproduction in type IV dental stone dried at room temperature and in a microwave oven
The type IV dental stone is widely used for the fabrication of dyes and master casts for fixed and removable partial prostheses. It is typically normal to wait at least 24 hours for the casts to dry prior to beginning the laboratory procedures. The waiting time has been shown to be greatly reduced by using microwave drying. This study evaluated the influence of drying techniques at room temperature and microwave oven on the linear dimensional change, compressive strength and detail reproduction in type IV dental stones. Three type IV dental stone brands were selected; elite Rock, Shera Premium and Durone IV. Two different drying protocols were tested in 4 groups (n=10); G-room temperature (25±4 ºC) dried for 2 hours; G2--room temperature dried for 24 hours; G3-room temperature dried for 7 days and G4--microwave oven dried at 800 W for 5 minutes and after 2 hours at room temperature. After drying, the samples were assayed for dimensional charges. The sample surface was submitted to the ImageTool 3.0 software for compressive strength in a universal testing machine with a cell load of 50 KN at a crosshead speed of 0.5 mm/minutes and the detail reproduction was analyzed with a stereomicroscope at 25x magnification. The statistical analysis of the linear dimensional change and compressive strength data were conducted by the ANOVA test followed by the Tukey test (p<0.05). Detailed reproduction values were reported in percentages. For the compressive strength test, Elite Rock and Durone IV did not present significant differences between G2 and G4, while Shera Premium did not present differences between G3 and G4. The best reproduction levels were observed for G3. Dental stone microwave oven drying showed a linear dimensional change similar to after room temperature drying for 24 hours and 7 days. The compressive strength of the stone dried in the microwave oven was similar to those dried at room temperature for 24 hours, with the exception of Shera Premium, which had similar results for microwave and room temperature drying for 7 days. For the microwave drying method the detail reproduction levels for samples dried at room temperature for 24 hours and 7 days were similar, except for the Durone IV.
- 1 October 2012
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 20 (5) , 588-593
Open AccessLinear dimensional change, compressive strength and detail reproduction in type IV dental stone dried at room temperature and in a microwave oven
The type IV dental stone is widely used for the fabrication of dyes and master casts for fixed and removable partial prostheses. It is typically normal to wait at least 24 hours for the casts to dry prior to beginning the laboratory procedures. The waiting time has been shown to be greatly reduced by using microwave drying. This study evaluated the influence of drying techniques at room temperature and microwave oven on the linear dimensional change, compressive strength and detail reproduction in type IV dental stones. Three type IV dental stone brands were selected; elite Rock, Shera Premium and Durone IV. Two different drying protocols were tested in 4 groups (n=10); G-room temperature (25±4 ºC) dried for 2 hours; G2--room temperature dried for 24 hours; G3-room temperature dried for 7 days and G4--microwave oven dried at 800 W for 5 minutes and after 2 hours at room temperature. After drying, the samples were assayed for dimensional charges. The sample surface was submitted to the ImageTool 3.0 software for compressive strength in a universal testing machine with a cell load of 50 KN at a crosshead speed of 0.5 mm/minutes and the detail reproduction was analyzed with a stereomicroscope at 25x magnification. The statistical analysis of the linear dimensional change and compressive strength data were conducted by the ANOVA test followed by the Tukey test (p<0.05). Detailed reproduction values were reported in percentages. For the compressive strength test, Elite Rock and Durone IV did not present significant differences between G2 and G4, while Shera Premium did not present differences between G3 and G4. The best reproduction levels were observed for G3. Dental stone microwave oven drying showed a linear dimensional change similar to after room temperature drying for 24 hours and 7 days. The compressive strength of the stone dried in the microwave oven was similar to those dried at room temperature for 24 hours, with the exception of Shera Premium, which had similar results for microwave and room temperature drying for 7 days. For the microwave drying method the detail reproduction levels for samples dried at room temperature for 24 hours and 7 days were similar, except for the Durone IV.
- 1 February 2011
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 17 (3) , 446-451
Analysis of Roughness and Surface Hardness of a Dental Composite Using Atomic Force Microscopy and Microhardness Testing
The objective of this study was to evaluate the influence of a cola soft drink (CSD) and coffee on the microhardness and surface roughness of composite resin. Fifty cavities were prepared on the vestibular surface of bovine incisors and restored with nanoparticulate resin. The teeth were divided into five groups (n= 10): group A (control), immersion in artificial saliva (AS) for 14 days; group B, immersion in coffee for 15 min (3×/day) for 7 days followed by immersion in AS for another 7 days; group C, immersion in CSD for 15 min (3×/day) for 7 days followed by immersion in AS for another 7 days; group D, immersion in AS for 7 days, immersion in coffee for 15 min (3×/day) for 7 days; group E, immersion in AS for 7 days, immersion in CSD for 15 min (3×/day) for 7 days. After the immersion periods the specimens were analyzed for their microhardness and surface roughness. The data were subjected to analysis of variance (ANOVA) followed byt-test with 5% significance. Group A presented the highest average microhardness and lowest surface roughness, so it was possible to conclude that the consumption of CSD and coffee alters the microhardness and surface roughness of new restorations.
- 1 February 2011
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 17 (3) , 446-451
Analysis of Roughness and Surface Hardness of a Dental Composite Using Atomic Force Microscopy and Microhardness Testing
The objective of this study was to evaluate the influence of a cola soft drink (CSD) and coffee on the microhardness and surface roughness of composite resin. Fifty cavities were prepared on the vestibular surface of bovine incisors and restored with nanoparticulate resin. The teeth were divided into five groups (n= 10): group A (control), immersion in artificial saliva (AS) for 14 days; group B, immersion in coffee for 15 min (3×/day) for 7 days followed by immersion in AS for another 7 days; group C, immersion in CSD for 15 min (3×/day) for 7 days followed by immersion in AS for another 7 days; group D, immersion in AS for 7 days, immersion in coffee for 15 min (3×/day) for 7 days; group E, immersion in AS for 7 days, immersion in CSD for 15 min (3×/day) for 7 days. After the immersion periods the specimens were analyzed for their microhardness and surface roughness. The data were subjected to analysis of variance (ANOVA) followed byt-test with 5% significance. Group A presented the highest average microhardness and lowest surface roughness, so it was possible to conclude that the consumption of CSD and coffee alters the microhardness and surface roughness of new restorations.