AHAndrew B. Haymet

Andrew B. Haymet

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew B. Haymet has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Porcine Model of Bilateral Hindlimb Bypass Graft Surgery Integrating Transit Time Flowmetry

    by Andrew B. Haymet, Cora Lau, Christina Cho, Sean O’lOughlin, Nigel V. Pinto, David C. McGiffin, Michael P. Vallely, Jacky Y. Suen, John F. Fraser

    Bypass graft surgery is a key surgical intervention for ischemic heart disease (coronary bypass graft surgery) and critical limb ischemia (peripheral bypass graft surgery). Graft occlusion remains a significant clinical problem for both types. Further research into the pathobiological mechanisms of graft occlusion are needed in order to design targeted therapeutic strategies. Three Large White female pigs (mean weight 52.3 +/- 4.4 kg) received general anaesthesia prior to surgery. The external jugular vein was harvested bilaterally, and a bilateral femoral peripheral arterial bypass was performed, with the superficial femoral artery permanently ligated. The grafts were interrogated immediately post operatively on-table using Medistim MiraQ transit time flowmetry system (Medistim, Oslo, Norway) to assess graft performance. On postoperative day three, the pigs were returned to the operating room, and the grafts were interrogated once again using transit time flowmetry. Six out of six (100%) successful bilateral EJV to femoral artery bypass grafts were performed. All pigs were successfully recovered, and returned to the operating room at postoperative day 3. The wounds were re-opened and the grafts were inspected. Postoperative graft assessment was performed with transit time flowmetry using the Medistim MiraQTM system (Medistim, Oslo, Norway), demonstrating all grafts were patent (100%). This model may serve as a platform to gain further mechanistic insight into graft failure pathobiology. By combining a bilateral graft model with gold-standard transit time flowmetry, longitudinal experimentation of targeted therapeutic interventions to combat graft failure may be further studied with improved objectivity.

  • Open Access

    The effects of nitric oxide on coagulation and inflammation in ex vivo models of extracorporeal membrane oxygenation and cardiopulmonary bypass

    by Maximilian V. Malfertheiner, Ashlen Garrett, Margaret Passmore, Andrew B. Haymet, Richard I. Webb, Viktor Von Bahr, Jonathan E. Millar, Bailey A. Schneider, Nchafatso G. Obonyo, Debra Black, et al.

    Background: Extracorporeal life support (ECLS) has extensive applications in managing patients with acute cardiac and pulmonary failure. Two primary modalities of ECLS, cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO), include several similarities in their composition, complications, and patient outcomes. Both CPB and ECMO pose a high risk of thrombus formation and platelet activation due to the large surface area of the devices and bleeding due to system anticoagulation. Therefore, novel methods of anticoagulation are needed to reduce the morbidity and mortality associated with extracorporeal support. Nitric oxide (NO) has potent antiplatelet properties and presents a promising alternative or addition to anticoagulation with heparin during extracorporeal support.Methods: We developed two ex vivo models of CPB and ECMO to investigate NO effects on anticoagulation and inflammation in these systems.Results: Sole addition of NO as an anticoagulant was not successful in preventing thrombus formation in the ex vivo setups, therefore a combination of low‐level heparin with NO was used. Antiplatelet effects were observed in the ex vivo ECMO model when NO was delivered at 80 ppm. Platelet count was preserved after 480 min when NO was delivered at 30 ppm.Conclusion: Combined delivery of NO and heparin did not improve haemocompatibility in either ex vivo model of CPB and ECMO. Anti‐inflammatory effects of NO in ECMO systems have to be evaluated further.


  • Open Access

    A comprehensive evaluation of hemodynamic energy production and circuit loss using four different ECMO arterial cannulae

    by Silver Heinsar, Nicole Bartnikowski, Gunter Hartel, Samia M. Farah, E‐Peng Seah, Eric Wu, Sebastiano Maria Colombo, Clayton Semenzin, Andrew Haymet, Indrek Rätsep, et al.

    Objective: Pulsatile‐flow veno‐arterial extracorporeal membrane oxygenation (V‐A ECMO) has shown encouraging results for microcirculation resuscitation and left ventricle unloading in patients with refractory cardiogenic shock. We aimed to comprehensively assess different V‐A ECMO parameters and their contribution to hemodynamic energy production and transfer through the device circuit.Methods: We used the i‐cor® ECMO circuit, which composed of Deltastream DP3 diagonal pump and i‐cor® console (Xenios AG), the Hilite 7000 membrane oxygenator (Xenios AG), venous and arterial tubing and a 1 L soft venous pseudo‐patient reservoir. Four different arterial cannulae (Biomedicus 15 and 17 Fr, Maquet 15 and 17 Fr) were used. For each cannula, 192 different pulsatile modes were investigated by adjusting flow rate, systole/diastole ratio, pulsatile amplitudes and frequency, yielding 784 unique conditions. A dSpace data acquisition system was used to collect flow and pressure data.Results: Increasing flow rates and pulsatile amplitudes were associated with significantly higher hemodynamic energy production (both p < 0.001), while no significant associations were seen while adjusting systole‐to‐diastole ratio (p = 0.73) or pulsing frequency (p = 0.99). Arterial cannula represents the highest resistance to hemodynamic energy transfer with 32%–59% of total hemodynamic energy generated being lost within, depending on pulsatile flow settings used.Conclusions: Herein, we presented the first study to compare hemodynamic energy production with all pulsatile ECLS pump settings and their combinations and widely used yet previously unexamined four different arterial ECMO cannula. Only increased flow rate and amplitude increase hemodynamic energy production as single factors, whilst other factors are relevant when combined.


  • Open Access

    Studying the Endothelial Glycocalyx in vitro: What Is Missing?

    by Andrew B. Haymet, Nicole Bartnikowski, Emily S. Wood, Michael P. Vallely, Angela McBride, Sophie Yacoub, Scott B. Biering, Eva Harris, Jacky Y. Suen, John F. Fraser

    All human cells are coated by a surface layer of proteoglycans, glycosaminoglycans (GAGs) and plasma proteins, called the glycocalyx. The glycocalyx transmits shear stress to the cytoskeleton of endothelial cells, maintains a selective permeability barrier, and modulates adhesion of blood leukocytes and platelets. Major components of the glycocalyx, including syndecans, heparan sulfate, and hyaluronan, are shed from the endothelial surface layer during conditions including ischaemia and hypoxia, sepsis, atherosclerosis, diabetes, renal disease, and some viral infections. Studying mechanisms of glycocalyx damage in vivo can be challenging due to the complexity of immuno-inflammatory responses which are inextricably involved. Previously, both static as well as perfused in vitro models have studied the glycocalyx, and have reported either imaging data, assessment of barrier function, or interactions of blood components with the endothelial monolayer. To date, no model has simultaneously incorporated all these features at once, however such a model would arguably enhance the study of vasculopathic processes. This review compiles a series of current in vitro models described in the literature that have targeted the glycocalyx layer, their limitations, and potential opportunities for further developments in this field.


  • Assessing potential for aortoiliac vascular injury from venoarterial extracorporeal membrane oxygenation cannulae: An in vitro particle image velocimetry study

    by Andrew B. Haymet, Alice Boone, Michael P. Vallely, Maximilian Valentin Malfertheiner, Jo P. Pauls, Jacky Y. Suen, John F. Fraser

    Background Limb ischemia is a major complication associated with peripheral veno‐arterial extracorporeal membrane oxygenation (VA ECMO). The high velocity jet from arterial cannulae can cause “sandblasting” injuries to the arterial endothelium, with the potential risk of distal embolization and end organ damage. Aim The aim of this study was to identify, for a range of clinically relevant VA ECMO cannulae and flow rates, any regions of peak flow velocity on the aortic wall which may predispose to vascular injury, and any regions of low velocity flow which may predispose to thrombus formation. Methods A silicone model of the aortic and iliac vessels was sourced and the right external iliac artery was cannulated. Cannulae ranged from 15 – 21 Fr in size. Simulated steady state ECMO flow rates were instituted using a magnetically levitated pump (CentriMag pump). Adaptive particle image velocimetry was performed for each cannula at 3, 3.5, 4 and 4.5 L/min. Results For all cannulae, in both horizontal and vertical side hole orientations, the peak velocity on the aortic wall ranged from 0.3 m/s ‐ 0.45 m/s, and the regions of lowest velocity flow were 0.05 m/s. The magnitude of peak velocity flow on the aortic wall was not different between a single pair versus multiple pairs of side holes. Maximum velocity flow on the aortic wall occurred earlier at a lower pump flow rate in the vertical orientation of distal side holes compared to a horizontal position. The presence of multiple paired side holes was associated with fewer low velocity flow regions, and some retrograde flow, in the distal abdominal aorta compared to cannulae with a single pair of side holes. Conclusion From this in vitro visualization study, the selection of a cannula design with multiple versus single pairs of side holes did not change the magnitude of peak velocity flow delivered to the vessel wall. Cannulae with multiple side holes were associated with fewer regions of low velocity flow in the distal abdominal aorta. Further in vivo studies, and ideally clinical data would be required to assess any correlation of peak velocity flows with incidence of vascular injury, and any low velocity flow regions with incidence of thrombosis.


  • Metabolic and Mitochondrial Alterations Following Brain Death and Heart Transplantation

    by L.E. See Hoe, M.A. Wells, M. Bouquet, K. Hyslop, M.R. Passmore, N. Bartnikowski, N.G. Obonyo, J. Reid, H. O'NEill, T. Shuker, et al.


  • When the Conventional Treatment Fails: A Rare Approach to Superior Mesenteric Arterial Embolization

    by Andrew B. Haymet, Daniel Lee, Kevin Ho-Shon, Richard Waugh

    Retroperitoneal haemorrhage is a rare but potentially life-threatening event. It may occur either spontaneously or secondary to percutaneous vascular access procedures, trauma, or ruptured aortic, iliac, or mesenteric aneurysms. As a result, the clinical presentation is variable. Computed tomography and/or angiography are vital for diagnosis. Management may range from conservative treatment for stable patients to emergency laparotomy or embolization for catastrophic haemorrhage. Direct percutaneous puncture of a deep intra-abdominal pseudoaneurysm is an accepted but infrequently performed technique due to a number of diagnostic and technical challenges. We describe the successful percutaneous transabdominal angioembolization of a superior mesenteric artery rupture in a 77-year-old woman with a large retroperitoneal haematoma. This was performed after a conventional femoral transarterial approach was unsuccessful.


  • Aortic perforation following transcatheter aortic valve deployment

    by Andrew B. Haymet, J. James B. Edelman, Michael Seco, Johan Duflou, Michael P. Vallely, H. K. Bernard Ng, Martin K. Ng, Michael K. Wilson