LRLuca Rosalia

Luca Rosalia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luca Rosalia has a total of 111 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Gradient Multinozzle 3D Printing

    by Luca Rosalia, Soham Sinha, Jonathan D. Weiss, Senming Hsia, Fredrik S. Solberg, Amit Sharir, Masufumi Shibata, Jianyi Du, Katelyn Mosle, Dominic R Rutsche, et al.

    Direct ink writing is compatible with an expansive materials palette. While enabling diverse applications, this materials versatility brings significant bottlenecks in ink formulation, often requiring the mixing, printing, and testing of dozens to hundreds of ink compositions over the course of a project. To accelerate ink-space exploration, we introduce gradient embedded multinozzle (GEM) printheads that combine the high-throughput parallelized printing of multinozzles with combinatorial ink mixing. These printheads allow simultaneous mixing of two-, three-, and four-input inks which are distributed to printer nozzles to create complex 3D structures with graded compositions of inks. Using a two-way GEM printhead, we vali-date cell compatibility by printing scaffolds containing various concentrations of fibroblasts and observing non-linear compaction behaviours. We next test a three-way GEM multinozzle to print ten compositions of di- and multi-functionalized poly(ethylene-glycol) diacrylate hydrogel tri-leaflet valves, optimizing for stiffness, swelling ratio, and toughness. Our GEM multinozzles are compatible with open-source printers and either pressure- or volume-driven extrusion systems and promise to accelerate iterative ink design and testing.


  • Open Access

    A Low‐Cost, Open‐Source 3D Printer for Multimaterial and High‐Throughput Direct Ink Writing of Soft and Living Materials

    by Jonathan D. Weiss, Alana Mermin‐Bunnell, Fredrik S. Solberg, Tony Tam, Luca Rosalia, Amit Sharir, Dominic Rütsche, Soham Sinha, Perry S. Choi, Masafumi Shibata, et al.

    Direct ink writing is a 3D printing method that is compatible with a wide range of structural, elastomeric, electronic, and living materials, and it continues to expand its uses into physics, engineering, and biology laboratories. However, the large footprint, closed hardware and software ecosystems, and expense of commercial systems often hamper widespread adoption. This work introduces a compact, low‐cost, multimaterial, and high‐throughput direct ink writing 3D printer platform with detailed assembly files and instructions provided freely online. In contrast to existing low‐cost 3D printers and bioprinters, which typically modify off‐the‐shelf plastic 3D printers, this system is built from scratch, offering a lower cost and full customizability. Active mixing of cell‐laden bioinks, high‐throughput production of auxetic lattices using multimaterial multinozzle 3D (MM3D) printing methods, and a high‐toughness, photocurable hydrogel for fabrication of heart valves are introduced. Finally, hardware for embedded multinozzle and 3D gradient nozzle printing is developed for producing high‐throughput and graded 3D parts. This powerful, simple‐to‐build, and customizable printing platform can help stimulate a vibrant biomaker community of engineers, biologists, and educators.


  • Open Access

    Programmable 3D cell alignment of bioprinted tissue via soft robotic dynamic stimulation

    by Luca Rosalia, Katelyn Mosle, Soham Sinha, Yi Yi Du, Fredrik Solberg, Allison Jia, Jonathan Weiss, Tony Tam, Jessica E. Herrmann, Mark Cutkosky, et al.

    Recent breakthroughs in biofabrication have enabled the development of engineered tissues for various organ systems, supporting applications in drug testing and regenerative medicine. However, current approaches do not allow for dynamic mechanical maturation of engineered tissue in 3D. Although uniaxial mechanostimulation techniques have shown promise in generating anisotropic tissues, they fail to recapitulate the biomechanics of complex tissues. As a result, existing biofabricated tissues lack the ability to replicate complex 3D alignment patterns essential for functional biomimicry. Here, we present a soft robotics-driven approach for programmable 3D alignment in 3D bioprinted tissue. Our method introduces the co-printing of biological tissue with a silicone-based soft robot via a custom core-double shell nozzle. The application of 3D, exogenous, dynamic expansion and torsional forces to the tissue via the co-printed silicone robot was found to drive cell alignment. Confocal imaging revealed pronounced anisotropy of the stimulated tissue samples compared to the unstimulated controls. In addition, different cellular orientation patterns resulted from each mode of stimulation, demonstrating the versatility of the soft robotic approach in tailoring the pattern of tissue alignment based on programmed mechanostimulation.


  • Open Access

    A low-cost, open-source 3D printer for multimaterial and high-throughput direct ink writing of soft and living materials

    by Jonathan D. Weiss, Alana Mermin-Bunnell, Fredrik S. Solberg, Tony Tam, Luca Rosalia, Amit Sharir, Dominic Rütsche, Soham Sinha, Perry S. Choi, Masafumi Shibata, et al.

    Direct ink writing is a 3D printing method that is compatible with a wide range of structural, elastomeric, electronic, and living materials, and it continues to expand its uses into physics, engineering, and biology laboratories. However, the large footprint, closed hardware and software ecosystems, and expense of commercial systems often hamper widespread adoption. Here, we present a compact, simple-to-build, low-cost, multimaterial, and high-throughput direct ink writing 3D printer platform with detailed assembly files and instructions provided freely online. In contrast to existing low-cost 3D printers and bioprinters, which typically modify off-the-shelf plastic 3D printers, this system is built from scratch, offering a lower cost and full customizability. Despite its low cost, we demonstrate advanced active mixing and multimaterial multinozzle 3D (MM3D) printing methods, which previously have relied on expensive and custom motion control platforms. We finally introduce embedded multinozzle and 3D gradient nozzle designs that offer high throughput and graded 3D parts. This powerful, easy-to-build, and customizable printing platform can help stimulate a vibrant biomaker community of engineers, biologists, and educators.


  • Soft robotic platform for progressive and reversible aortic constriction in a small-animal model

    by Luca Rosalia, Sophie X. Wang, Caglar Ozturk, Wei Huang, Jean Bonnemain, Rachel Beatty, Garry P. Duffy, Christopher T. Nguyen, Ellen T. Roche

    Our understanding of cardiac remodeling processes due to left ventricular pressure overload derives largely from animal models of aortic banding. However, these studies fail to enable control over both disease progression and reversal, hindering their clinical relevance. Here, we describe a method for progressive and reversible aortic banding based on an implantable expandable actuator that can be finely tuned to modulate aortic banding and debanding in a rat model. Through catheterization, imaging, and histologic studies, we demonstrate that our platform can recapitulate the hemodynamic and structural changes associated with pressure overload in a controllable manner. We leveraged soft robotics to enable noninvasive aortic debanding, demonstrating that these changes can be partly reversed because of cessation of the biomechanical stimulus. By recapitulating longitudinal disease progression and reversibility, this animal model could elucidate fundamental mechanisms of cardiac remodeling and optimize timing of intervention for pressure overload.


  • Open Access

    Modulating Cardiac Hemodynamics Using Tunable Soft Robotic Sleeves in a Porcine Model of HFpEF Physiology for Device Testing Applications

    by Luca Rosalia, Caglar Ozturk, Sophie X. Wang, Diego Quevedo‐Moreno, Mossab Y. Saeed, Adam Mauskapf, Ellen T. Roche

    Heart failure with preserved ejection fraction (HFpEF) is a major challenge in cardiovascular medicine, accounting for ≈50% of all cases of heart failure. Despite the ongoing efforts, no medical device has yet received FDA approval. This is largely due to the lack of an in vivo model of the HFpEF hemodynamics, resulting in the inability to evaluate device effectiveness in vivo prior to clinical trials. Here, the development of a highly tunable porcine model of HFpEF hemodynamics is described using implantable soft robotic sleeves, where controlled actuation of a left ventricular and an aortic sleeve can recapitulate changes in ventricular compliance and afterload associated with a broad spectrum of HFpEF hemodynamic phenotypes. The feasibility of the proposed model in preclinical testing is demonstrated by evaluating the hemodynamic response of the model post‐implantation of an interatrial shunt device, which is found to be consistent with findings from in silico studies and clinical trials. This work overcomes limitations of prior HFpEF models, such as low hemodynamic accuracy, high costs, and long development phases. The versatile and adjustable platform introduced can transform HFpEF device development, aiming to enhance the lives of the 32 million people affected globally.


  • Open Access

    A Soft Robotic Actuator System for In Vivo Modeling of Normal Pressure Hydrocephalus

    by Fabian Flürenbrock, Luca Rosalia, Anthony Podgoršak, Katherina Sapozhnikov, Nina Eva Trimmel, Miriam Weisskopf, Markus Florian Oertel, Ellen Roche, Melanie N. Zeilinger, Leonie Korn, et al.

    Objective : The intracranial pressure (ICP) affects the dynamics of cerebrospinal fluid (CSF) and its waveform contains information that is of clinical importance in medical conditions such as hydrocephalus. Active manipulation of the ICP waveform could enable the investigation of pathophysiological processes altering CSF dynamics and driving hydrocephalus. Methods : A soft robotic actuator system for intracranial pulse pressure amplification was developed to model normal pressure hydrocephalus in vivo . Different end actuators were designed for intraventricular implantation and manufactured by applying cyclic tensile loading on soft rubber tubing. Their mechanical properties were investigated, and the type that achieved the greatest pulse pressure amplification in an in vitro simulator of CSF dynamics was selected for application in vivo . A hydraulic actuation device based on a linear voice coil motor was developed to enable automated and fast operation of the end actuators. The combined system was validated in an acute ovine pilot in vivo study. Results : In vitro results show that variations in the used materials and manufacturing settings altered the end actuator's dynamic properties, such as the pressure-volume characteristics. In the in vivo model, a cardiac-gated actuation volume of 0.125 mL at a heart rate of 62 bpm caused an increase of 205% in mean peak-to-peak amplitude but only an increase of 1.3% in mean ICP. Conclusion : The introduced soft robotic actuator system is capable of ICP waveform manipulation. Significance : Continuous amplification of the intracranial pulse pressure could enable in vivo modeling of normal pressure hydrocephalus and shunt system testing under pathophysiological conditions to improve therapy for hydrocephalus.


  • Open Access

    Soft robotics-enabled large animal model of HFpEF hemodynamics for device testing

    by Luca Rosalia, Caglar Ozturk, Sophie X. Wang, Diego Quevedo-Moreno, Mossab Y. Saeed, Adam Mauskapf, Ellen T. Roche

    Heart failure with preserved ejection fraction (HFpEF) is a major challenge in cardiovascular medicine, accounting for approximately 50% of all cases of heart failure. Due to the lack of effective therapies for this condition, the mortality associated with HFpEF remains higher than that of most cancers. Despite the ongoing efforts, no medical device has yet received FDA approval. This is largely due to the lack of an in vivo model of the HFpEF hemodynamics, resulting in the inability to evaluate device effectiveness in vivo prior to clinical trials. Here, we describe the development of a highly tunable porcine model of HFpEF hemodynamics using implantable soft robotic sleeves, where controlled actuation of a left ventricular and an aortic sleeve can recapitulate changes in ventricular compliance and afterload associated with a broad spectrum of HFpEF hemodynamic phenotypes. We demonstrate the feasibility of the proposed model in preclinical testing by evaluating the hemodynamic response of the model post-implantation of an interatrial shunt device, which was found to be consistent with findings from in silico studies and clinical trials. This work addresses several of the limitations associated with previous models of HFpEF, such as their limited hemodynamic fidelity, elevated costs, lengthy development time, and low throughput. By showcasing exceptional versatility and tunability, the proposed platform has the potential to revolutionize the current approach for HFpEF device development and selection, with the goal of improving the quality of life for the 32 million people affected by HFpEF worldwide.


  • Open Access

    Soft robotic platform for controlled, progressive and reversible aortic constriction in a small animal model

    by Ellen Roche, Luca Rosalia, Sophie Wang, Caglar Ozturk, Wei Huang, Jean Bonnemain, Rachel Beatty, Garry Duffy, Christopher Nguyen

    Our understanding of cardiac remodeling processes due to left ventricular pressure overload derives largely from animal models of aortic banding. However, these studies fail to simultaneously enable control over disease progression and reversal, hindering their clinical relevance. Here, we describe a method for controlled, progressive, and reversible aortic banding based on an implantable expandable actuator that can be finely controlled to modulate aortic banding and debanding in a rat model. Through catheterization, imaging, and histologic studies, we demonstrate that our model can recapitulate the hemodynamic and structural changes associated with pressure overload in a controllable manner. We leverage the ability of our model to enable non-invasive aortic debanding to show that these changes can be partly reversed due to cessation of the biomechanical stimulus. By recapitulating longitudinal disease progression and reversibility, this model could elucidate fundamental mechanisms of cardiac remodeling and optimize timing of intervention for pressure overload.

  • Open Access

    Recapitulation of single ventricle haemodynamics and associated interplay with breathing mechanics using clinically validated multimodal simulators

    by Markus Horvath, David van Story, Luca Rosalia, Bryce Starr, Mulan Jiang, David Annese, Breanna Piekarski, Caglar Ozturk, Stephanie Agudelo, Kinsey Brassaw, et al.

    A range of congenital heart diseases result in a single functioning ventricle. This is palliatively treated by connecting the systemic and pulmonary vasculature in series, establishing what is known as the Fontan circulation. This physiology allows post-natal survival but causes aberrant haemodynamics that causes high morbidity and mortality. Due to limited clinical data, accurate modelling of single ventricle haemodynamics is critical for improving patient care. Although sophisticated haemodynamic models have been developed, their clinical relevance is hindered by their inability to mimic the biomechanical interactions of breathing pressures with vascular reservoirs as one interdependent unit which governs flow patterns and flow reversal in this physiology. Here, we report the development of a tuneable biomimetic single ventricle simulator platform that re-creates breathing mechanics and recapitulates Fontan venous flow patterns. Benchtop characterization, computational modelling, and MRI-based clinical validation demonstrate the ability of the platform to emulate the underlying mechanisms of the coupled breathing and flow mechanics that lead to venous flow reversal. We leverage this multimodal simulator platform to identify respiratory effort and rate as independent drivers for increased caval flow reversal in the Fontan physiology and measure haemodynamic parameters that cannot be obtained comprehensively in the clinic. Enabled by the modularity of this class of simulators, we evaluate the impact of gravity on the relationship between respiration and flow. Finally, we demonstrate the suitability of the clinically validated in vitro and in silico simulators as test platforms for Fontan support strategies which can help guide development of interventions to improve patient’s quality of life.