CSChristian Seim

Christian Seim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christian Seim has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Bernhard Hesse

    Xploraytion GmbH, Invalidenstraße 34, 10115 Berlin, Germany

    2 shared publications
  • Andreas Luch

    Department of Chemical & Product Safety, German Federal Institute for Risk Assessment (BfR), Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany

    1 shared publication
  • Antje Ludwig

    Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Medizinische Klinik für Kardiologie und Angiologie, Campus Mitte, Charitéplatz 1, 10117 Berlin, Germany

    1 shared publication
  • Aurelie Dehlinger

    Technische Universität Berlin, Institut für Optik und Atomare Physik, Hardenbergstraße 36, Berlin 10623, Germany

    1 shared publication
  • Aurélie Dehlinger

    Technische Universität Berlin, Institut für Physik und Astronomie , Hardenbergstr. 36 Berlin 10623

    1 shared publication
  • Bernd Küstner

    Merck KGaA, 64293 Darmstadt, Germany

    1 shared publication

Latest Publications

  • Laboratory-Based Soft X-Ray Tomography: A Novel Laser Design, Source Monitoring, and Data-Processing Workflow

    by Aurélie Dehlinger, Valentina Alberini, Vladimir Usatikov, Céline Dyhring, Sarah Jung, Jonas Grage, Daniel Grötzsch, Johannes Tümmler, Stefan Rehbein, Holger Stiel, et al.

    Method development for laboratory-based X-ray microscopes operating in the water-window range invariably involves the development of the X-ray source as well. This paper presents major upgrades to the laboratory soft X-ray microscope (L-TXM) plasma chamber and data analysis protocol. Characterization of the laser-plasma source demonstrates improved performance, while a proof-of-principle tomogram of a diatom showcases a robust data treatment protocol and the system's capabilities for three-dimensional imaging and segmentation. These developments mark significant progress toward making L-TXM a more robust and user-friendly tool for soft X-ray microscopy applications.


  • Static and in-situ synchrotron X-ray microtomography analysis of pharmaceutical tablets

    by Christian Seim, Javier Gerber, Jussi-Petteri Suuronen, Emely Bortel, Bernd Küstner, Lena Müller, Jean Doucet, Luiz Schweitzer, Enni Mattern, Peter Westenberger, et al.


  • Laboratory Soft X-Ray Microscopy with an Integrated Visible-Light Microscope—Correlative Workflow for Faster 3D Cell Imaging

    by Aurélie Dehlinger, Christian Seim, Holger Stiel, Shailey Twamley, Antje Ludwig, Mikael Kördel, Daniel Grötzsch, Stefan Rehbein, Birgit Kanngießer

    Laboratory transmission soft X-ray microscopy (L-TXM) has emerged as a complementary tool to synchrotron-based TXM and high-resolution biomedical 3D imaging in general in recent years. However, two major operational challenges in L-TXM still need to be addressed: a small field of view and a potentially misaligned rotation stage. As it is not possible to alter the magnification during operation, the field of view in L-TXM is usually limited to a few tens of micrometers. This complicates locating areas and objects of interest in the sample. Additionally, if the rotation axis of the sample stage cannot be adjusted prior to the experiments, an efficient workflow for tomographic imaging cannot be established, as refocusing and sample repositioning will become necessary after each recorded projection. Both these limitations have been overcome with the integration of a visible-light microscope (VLM) into the L-TXM system. Here, we describe the calibration procedure of the goniometer sample stage and the integrated VLM and present the resulting 3D imaging of a test sample. In addition, utilizing this newly integrated VLM, the extracellular matrix of cryofixed THP-1 cells (human acute monocytic leukemia cells) was visualized by L-TXM for the first time in the context of an ongoing biomedical research project.


  • Open Access

    Identification of pigments related to allergic tattoo reactions in 104 human skin biopsies

    by Jørgen Serup, Katrina Hutton Carlsen, Nils Dommershausen, Mitra Sepehri, Bernhard Hesse, Christian Seim, Andreas Luch, Ines Schreiver

    Background: Red tattoos are prone to allergic reactions. The identity of the allergen(s) is mostly unknown.Objectives: Chemical analysis of human skin biopsies from chronic allergic reactions in red tattoos to identify culprit pigment(s) and metals.Material and methods: One hundred four dermatome biopsies were analyzed by matrix‐assisted laser desorption/ionization tandem mass spectrometry (MALDI‐MS/MS) for identification of commonly used organic pigments. Metal concentrations were assessed by inductively coupled plasma (ICP)‐MS and x‐ray fluorescence (XRF). Fourteen patients had cross‐reactions in other red tattoos.Results: In total, the identified pigments were mainly azo Pigment Red (P.R.) 22 (35%), P.R. 210 (24%), P.R. 170 (12%), P.R. 5 (0.9%), P.R. 112 (0.9%), and Pigment Orange (P.O.) 13 (11%). P.R. 122 (0.9%) and Pigment Violet (P.V.) 23 (8%) were also common. P.R. 22, P.R. 170, and P.R. 210 also dominated in patients with cross‐reactions. In 22% of the biopsies, no red pigment was detected. Element analysis indicated the presence of the sensitizers nickel and chromium.Conclusions: P.R. 22, P.R. 170, and P.R. 210 were identified as the prevailing pigments behind chronic allergic reactions in red tattoos. The epitope causing the reaction might be a pigment‐degradation product. Metal contamination may derive from different sources, and its role in red tattoo allergy cannot be ascertained.