Daniel Rosenkranz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Rosenkranz has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Fabian Lukas Kriegel
Department of Chemical & Product Safety, German Federal Institute for Risk Assessment (BfR), Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany
3 shared publications Andreas Luch
Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR)
2 shared publications- Andreas Luch
Department of Chemical & Product Safety, German Federal Institute for Risk Assessment (BfR), Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany
2 shared publications - Benjamin-Christoph Krause
Department of Chemical & Product Safety, German Federal Institute for Risk Assessment (BfR), Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany
2 shared publications Emmanouil Mavrakis
Environmental Chemical Processes Laboratory, Department of Chemistry, University of Crete
2 shared publications- Gunnar Brandhorst
Institute for Clinical Chemistry and Laboratory Medicine, University Medicine Oldenburg , Oldenburg , Germany
2 shared publications
Latest Publications
- Open Access
- 27 May 2025
- Published by Walter de Gruyter GmbH in Journal of Laboratory Medicine
Evaluation of hemolysis index thresholds for 18 biochemistry assays: implications for laboratory-developed tests in the era of the IVDR
Objectives: Hemolysis in laboratory samples is a frequent error that may lead to clinical misinterpretation and incorrect patient treatment. Thus, modern laboratory analyzers are able to assess the hemolysis index (HI). To prevent reporting of erroneous results, manufacturers are obliged to provide reliable HI threshold values. The aim of this study was to proof the quality of manufacturer’s given HI thresholds. Methods: Dilution series with defined degrees of hemolysis were prepared by using blood samples from voluntary participants (n=77). In addition to the HI in each dilution, 18 measurands, namely sodium, potassium, chloride, aspartate aminotransferase (ASAT), alanine aminotransferase (ALAT), gamma-glutamyl transferase (GGT), lactate dehydrogenase (LDH), haptoglobin, total bilirubin, direct bilirubin, glutamate dehydrogenase (GLDH), creatine kinase (CK), iron, amylase, phosphate, total protein, enzymatic creatinine and high-sensitive troponin T, were measured on a cobas®pro analyzer. Thresholds for maximum deviation of measurement results of 5 , 10 and 20 % were calculated. Then we determined cut-offs as the 5th percentile and median. Results: Using potassium as an example we found HI thresholds at 57 (5th percentile) and 70 (median) with a corresponding result deviation of 5 % while the manufacturer HI threshold is given at 20. Thus, a higher HI threshold might be tolerated. Conclusions: We established HI thresholds for 18 biochemistry assays. Eight assays showed considerable deviations of which six may have potential clinical relevance like potassium and high-sensitive troponin T. Optimizing thresholds can help to reduce the risk of unnecessary blocking of results and preventing considerably impaired results from being released.
- 27 May 2025
- Published by Walter de Gruyter GmbH in Journal of Laboratory Medicine
Open AccessEvaluation of hemolysis index thresholds for 18 biochemistry assays: implications for laboratory-developed tests in the era of the IVDR
Objectives: Hemolysis in laboratory samples is a frequent error that may lead to clinical misinterpretation and incorrect patient treatment. Thus, modern laboratory analyzers are able to assess the hemolysis index (HI). To prevent reporting of erroneous results, manufacturers are obliged to provide reliable HI threshold values. The aim of this study was to proof the quality of manufacturer’s given HI thresholds. Methods: Dilution series with defined degrees of hemolysis were prepared by using blood samples from voluntary participants (n=77). In addition to the HI in each dilution, 18 measurands, namely sodium, potassium, chloride, aspartate aminotransferase (ASAT), alanine aminotransferase (ALAT), gamma-glutamyl transferase (GGT), lactate dehydrogenase (LDH), haptoglobin, total bilirubin, direct bilirubin, glutamate dehydrogenase (GLDH), creatine kinase (CK), iron, amylase, phosphate, total protein, enzymatic creatinine and high-sensitive troponin T, were measured on a cobas®pro analyzer. Thresholds for maximum deviation of measurement results of 5 , 10 and 20 % were calculated. Then we determined cut-offs as the 5th percentile and median. Results: Using potassium as an example we found HI thresholds at 57 (5th percentile) and 70 (median) with a corresponding result deviation of 5 % while the manufacturer HI threshold is given at 20. Thus, a higher HI threshold might be tolerated. Conclusions: We established HI thresholds for 18 biochemistry assays. Eight assays showed considerable deviations of which six may have potential clinical relevance like potassium and high-sensitive troponin T. Optimizing thresholds can help to reduce the risk of unnecessary blocking of results and preventing considerably impaired results from being released.
- 26 August 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (2) , 291-299
IVDCheckR – simplifying documentation for laboratory developed tests according to IVDR requirements by introducing a new digital tool
Objectives: A recent challenge for clinical laboratories is the lack of clear guidelines for handling significant modifications of CE-marked assays. The modifications may involve, for example, extending measurement intervals, changing dilution procedures or using non-validated sample materials. The challenge arises due to the amended Regulation (EU) 2017/746 on in vitro diagnostic medical devices (IVDR), which is now poised for implementation, despite the extended transition periods. The IVDR application imposes challenges not only for diagnostic companies but also for clinical laboratories when using laboratory developed tests (LDTs), often referred to as in-house assays. In this context, a coherent and meticulously structured LDT documentation is highly beneficial. While laboratories are obliged to meet the IVDR requirements, the absence of a streamlined framework or guideline hampers the ability to gain a comprehensive overview on the requirements and possible options for their fulfilment. Methods: To address this issue, we introduce a web based digital tool powered by an R Shiny web application. This tool facilitates a seamless implementation of IVDR requirements for LDTs across diverse laboratory environments in terms of their transparency and validity. Our approach focuses on adequate handling of significant modifications of CE-marked in vitro diagnostic medical devices (IVD). Results: IVDRCheckR is an open-source tool that is easily accessible and free from system dependencies. The tool promotes a seamless process and a guide to enhance transparency, reliability, and validity of laboratory examination results based on LDTs. Additionally, the tool further provides modules for evaluating quality control data and quantitative method comparison data. Conclusions: Our Shiny web application-based platform is a digitised, user-friendly tool that simplifies the documentation for LDTs according to IVDR requirements with special emphasis on solutions for handling modifications to CE-marked assays.
- 26 August 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (2) , 291-299
IVDCheckR – simplifying documentation for laboratory developed tests according to IVDR requirements by introducing a new digital tool
Objectives: A recent challenge for clinical laboratories is the lack of clear guidelines for handling significant modifications of CE-marked assays. The modifications may involve, for example, extending measurement intervals, changing dilution procedures or using non-validated sample materials. The challenge arises due to the amended Regulation (EU) 2017/746 on in vitro diagnostic medical devices (IVDR), which is now poised for implementation, despite the extended transition periods. The IVDR application imposes challenges not only for diagnostic companies but also for clinical laboratories when using laboratory developed tests (LDTs), often referred to as in-house assays. In this context, a coherent and meticulously structured LDT documentation is highly beneficial. While laboratories are obliged to meet the IVDR requirements, the absence of a streamlined framework or guideline hampers the ability to gain a comprehensive overview on the requirements and possible options for their fulfilment. Methods: To address this issue, we introduce a web based digital tool powered by an R Shiny web application. This tool facilitates a seamless implementation of IVDR requirements for LDTs across diverse laboratory environments in terms of their transparency and validity. Our approach focuses on adequate handling of significant modifications of CE-marked in vitro diagnostic medical devices (IVD). Results: IVDRCheckR is an open-source tool that is easily accessible and free from system dependencies. The tool promotes a seamless process and a guide to enhance transparency, reliability, and validity of laboratory examination results based on LDTs. Additionally, the tool further provides modules for evaluating quality control data and quantitative method comparison data. Conclusions: Our Shiny web application-based platform is a digitised, user-friendly tool that simplifies the documentation for LDTs according to IVDR requirements with special emphasis on solutions for handling modifications to CE-marked assays.
- Open Access
- 2 March 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (5) , 922
Nanomaterial Characterization in Complex Media—Guidance and Application
A broad range of inorganic nanoparticles (NPs) and their dissolved ions possess a possible toxicological risk for human health and the environment. Reliable and robust measurements of dissolution effects may be influenced by the sample matrix, which challenges the analytical method of choice. In this study, CuO NPs were investigated in several dissolution experiments. Two analytical techniques (dynamic light scattering (DLS) and inductively-coupled plasma mass spectrometry (ICP-MS)) were used to characterize NPs (size distribution curves) time-dependently in different complex matrices (e.g., artificial lung lining fluids and cell culture media). The advantages and challenges of each analytical approach are evaluated and discussed. Additionally, a direct-injection single particle (DI sp)ICP-MS technique for assessing the size distribution curve of the dissolved particles was developed and evaluated. The DI technique provides a sensitive response even at low concentrations without any dilution of the complex sample matrix. These experiments were further enhanced with an automated data evaluation procedure to objectively distinguish between ionic and NP events. With this approach, a fast and reproducible determination of inorganic NPs and ionic backgrounds can be achieved. This study can serve as guidance when choosing the optimal analytical method for NP characterization and for the determination of the origin of an adverse effect in NP toxicity.
- 2 March 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (5) , 922
Open AccessNanomaterial Characterization in Complex Media—Guidance and Application
A broad range of inorganic nanoparticles (NPs) and their dissolved ions possess a possible toxicological risk for human health and the environment. Reliable and robust measurements of dissolution effects may be influenced by the sample matrix, which challenges the analytical method of choice. In this study, CuO NPs were investigated in several dissolution experiments. Two analytical techniques (dynamic light scattering (DLS) and inductively-coupled plasma mass spectrometry (ICP-MS)) were used to characterize NPs (size distribution curves) time-dependently in different complex matrices (e.g., artificial lung lining fluids and cell culture media). The advantages and challenges of each analytical approach are evaluated and discussed. Additionally, a direct-injection single particle (DI sp)ICP-MS technique for assessing the size distribution curve of the dissolved particles was developed and evaluated. The DI technique provides a sensitive response even at low concentrations without any dilution of the complex sample matrix. These experiments were further enhanced with an automated data evaluation procedure to objectively distinguish between ionic and NP events. With this approach, a fast and reproducible determination of inorganic NPs and ionic backgrounds can be achieved. This study can serve as guidance when choosing the optimal analytical method for NP characterization and for the determination of the origin of an adverse effect in NP toxicity.
- 24 September 2020
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 163,p. e61653
Versatile Dual-Inlet Sample Introduction System for Multi-Mode Single Particle Inductively Coupled Plasma Mass Spectrometry Analysis and Validation
Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration. Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet generator (µDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of µDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running. Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle. While mode I (counting) and mode III (µDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic standard solutions only. It is independent of NP reference materials. The µDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.
- 24 September 2020
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 163,p. e61653
Versatile Dual-Inlet Sample Introduction System for Multi-Mode Single Particle Inductively Coupled Plasma Mass Spectrometry Analysis and Validation
Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration. Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet generator (µDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of µDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running. Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle. While mode I (counting) and mode III (µDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic standard solutions only. It is independent of NP reference materials. The µDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.
- Open Access
Tackling Complex Analytical Tasks: An ISO/TS-Based Validation Approach for Hydrodynamic Chromatography Single Particle Inductively Coupled Plasma Mass Spectrometry
Nano-carrier systems such as liposomes have promising biomedical applications. Nevertheless, characterization of these complex samples is a challenging analytical task. In this study a coupled hydrodynamic chromatography-single particle-inductively coupled plasma mass spectrometry (HDC-spICP-MS) approach was validated based on the technical specification (TS) 19590:2017 of the international organization for standardization (ISO). The TS has been adapted to the hyphenated setup. The quality criteria (QC), e.g., linearity of the calibration, transport efficiency, were investigated. Furthermore, a cross calibration of the particle size was performed with values from dynamic light scattering (DLS) and transmission electron microscopy (TEM). Due to an additional Y-piece, an online-calibration routine was implemented. This approach allows the calibration of the ICP-MS during the dead time of the chromatography run, to reduce the required time and enhance the robustness of the results. The optimized method was tested with different gold nanoparticle (Au-NP) mixtures to investigate the characterization properties of HDC separations for samples with increasing complexity. Additionally, the technique was successfully applied to simultaneously determine both the hydrodynamic radius and the Au-NP content in liposomes. With the established hyphenated setup, it was possible to distinguish between different subpopulations with various NP loads and different hydrodynamic diameters inside the liposome carriers.
Open AccessTackling Complex Analytical Tasks: An ISO/TS-Based Validation Approach for Hydrodynamic Chromatography Single Particle Inductively Coupled Plasma Mass Spectrometry
Nano-carrier systems such as liposomes have promising biomedical applications. Nevertheless, characterization of these complex samples is a challenging analytical task. In this study a coupled hydrodynamic chromatography-single particle-inductively coupled plasma mass spectrometry (HDC-spICP-MS) approach was validated based on the technical specification (TS) 19590:2017 of the international organization for standardization (ISO). The TS has been adapted to the hyphenated setup. The quality criteria (QC), e.g., linearity of the calibration, transport efficiency, were investigated. Furthermore, a cross calibration of the particle size was performed with values from dynamic light scattering (DLS) and transmission electron microscopy (TEM). Due to an additional Y-piece, an online-calibration routine was implemented. This approach allows the calibration of the ICP-MS during the dead time of the chromatography run, to reduce the required time and enhance the robustness of the results. The optimized method was tested with different gold nanoparticle (Au-NP) mixtures to investigate the characterization properties of HDC separations for samples with increasing complexity. Additionally, the technique was successfully applied to simultaneously determine both the hydrodynamic radius and the Au-NP content in liposomes. With the established hyphenated setup, it was possible to distinguish between different subpopulations with various NP loads and different hydrodynamic diameters inside the liposome carriers.