SeyyedKazem HashemizadehKolowri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
SeyyedKazem HashemizadehKolowri has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Edward V. R. DiBella
Department of Biomedical Engineering, University of Utah, SLC, USA
5 shared publications Ganesh Adluru
Department of Radiology and Imaging Sciences University of Utah Salt Lake City UT USA
2 shared publicationsRong-Rong Chen
Electrical and Computer Engineering Department, University of Utah, Salt Lake City, UT, USA
2 shared publications- Xiaodong Ma
Department of Radiology and Imaging Sciences University of Utah Salt Lake City Utah USA
2 shared publications - Abhishek Tiwari
Department of Computer Science and Engineering, Shiv Nadar Institution of Eminence, Delhi NCR, India
1 shared publication - Abrar Faiyaz
Department of Neurology, University of Rochester, Rochester, NY 14642, USA
1 shared publication
Latest Publications
- Open Access
- 10 April 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 727-740
Simultaneous Assessment of Intracranial Artery and Paravascular CSF Pulsation Using 3D Whole‐Brain Diffusion‐Prepared Cine bSSFP ( DECAF ) MRI
Purpose: To propose a noninvasive and quantitative MRI approach to simultaneously assessing intracranial artery pulsation and paravascular cerebrospinal fluid (CSF) pulsation in the human brain. Methods: We developed a 3D whole‐brain Diffusion‐prepared Cine bSSFP (DECAF) MRI technique, with improved motion‐sensitized driven‐equilibrium providing blood suppression and diffusion weighting. 3D golden‐angle radial trajectory, retrospective pulse gating, and GRASP image reconstruction were employed to generate cine images of 25 phases. Semi‐automatic image processing pipelines were established to quantify the arterial wall pulsatility index and the paravascular CSF pulsatility index. The ADC quantification was corrected using an analytical approach to remove T1 and T2 effects based on bSSFP. The efficacy of our proposed technique was validated on six healthy participants. Results: The developed MRI sequence was able to generate high‐resolution whole‐brain cine images with 25 cardiac phases in approximately 8 min. Reliable arterial wall and paravascular CSF pulsatility indices were quantified in the human brain with good scan–rescan reproducibility. A strong temporal relationship between those two pulsations was observed in the six participants. There is a spatial relationship between CSF pulsation and distance to arteries. In addition, the arterial wall and paravascular CSF pulsation indices are significantly correlated. Conclusion: We developed and demonstrated a DECAF MR technique, combined with an automatic image processing pipeline, enabling simultaneous quantification of intracranial artery pulsation and paravascular CSF pulsation across the cardiac cycle. This technique can be a noninvasive and quantitative imaging tool for investigating the relationship between vascular or aging‐related diseases and glymphatic dysfunction.
- 10 April 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 727-740
Open AccessSimultaneous Assessment of Intracranial Artery and Paravascular CSF Pulsation Using 3D Whole‐Brain Diffusion‐Prepared Cine bSSFP ( DECAF ) MRI
Purpose: To propose a noninvasive and quantitative MRI approach to simultaneously assessing intracranial artery pulsation and paravascular cerebrospinal fluid (CSF) pulsation in the human brain. Methods: We developed a 3D whole‐brain Diffusion‐prepared Cine bSSFP (DECAF) MRI technique, with improved motion‐sensitized driven‐equilibrium providing blood suppression and diffusion weighting. 3D golden‐angle radial trajectory, retrospective pulse gating, and GRASP image reconstruction were employed to generate cine images of 25 phases. Semi‐automatic image processing pipelines were established to quantify the arterial wall pulsatility index and the paravascular CSF pulsatility index. The ADC quantification was corrected using an analytical approach to remove T1 and T2 effects based on bSSFP. The efficacy of our proposed technique was validated on six healthy participants. Results: The developed MRI sequence was able to generate high‐resolution whole‐brain cine images with 25 cardiac phases in approximately 8 min. Reliable arterial wall and paravascular CSF pulsatility indices were quantified in the human brain with good scan–rescan reproducibility. A strong temporal relationship between those two pulsations was observed in the six participants. There is a spatial relationship between CSF pulsation and distance to arteries. In addition, the arterial wall and paravascular CSF pulsation indices are significantly correlated. Conclusion: We developed and demonstrated a DECAF MR technique, combined with an automatic image processing pipeline, enabling simultaneous quantification of intracranial artery pulsation and paravascular CSF pulsation across the cardiac cycle. This technique can be a noninvasive and quantitative imaging tool for investigating the relationship between vascular or aging‐related diseases and glymphatic dysfunction.
- Open Access
- 15 August 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (8) , 249
Efficient and Accurate 3D Thickness Measurement in Vessel Wall Imaging: Overcoming Limitations of 2D Approaches Using the Laplacian Method
The clinical significance of measuring vessel wall thickness is widely acknowledged. Recent advancements have enabled high-resolution 3D scans of arteries and precise segmentation of their lumens and outer walls; however, most existing methods for assessing vessel wall thickness are 2D. Despite being valuable, reproducibility and accuracy of 2D techniques depend on the extracted 2D slices. Additionally, these methods fail to fully account for variations in wall thickness in all dimensions. Furthermore, most existing approaches are difficult to be extended into 3D and their measurements lack spatial localization and are primarily confined to lumen boundaries. We advocate for a shift in perspective towards recognizing vessel wall thickness measurement as inherently a 3D challenge and propose adapting the Laplacian method as an outstanding alternative. The Laplacian method is implemented using convolutions, ensuring its efficient and rapid execution on deep learning platforms. Experiments using digital phantoms and vessel wall imaging data are conducted to showcase the accuracy, reproducibility, and localization capabilities of the proposed approach. The proposed method produce consistent outcomes that remain independent of centerlines and 2D slices. Notably, this approach is applicable in both 2D and 3D scenarios. It allows for voxel-wise quantification of wall thickness, enabling precise identification of wall volumes exhibiting abnormal wall thickness. Our research highlights the urgency of transitioning to 3D methodologies for vessel wall thickness measurement. Such a transition not only acknowledges the intricate spatial variations of vessel walls, but also opens doors to more accurate, localized, and insightful diagnostic insights.
- 15 August 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (8) , 249
Open AccessEfficient and Accurate 3D Thickness Measurement in Vessel Wall Imaging: Overcoming Limitations of 2D Approaches Using the Laplacian Method
The clinical significance of measuring vessel wall thickness is widely acknowledged. Recent advancements have enabled high-resolution 3D scans of arteries and precise segmentation of their lumens and outer walls; however, most existing methods for assessing vessel wall thickness are 2D. Despite being valuable, reproducibility and accuracy of 2D techniques depend on the extracted 2D slices. Additionally, these methods fail to fully account for variations in wall thickness in all dimensions. Furthermore, most existing approaches are difficult to be extended into 3D and their measurements lack spatial localization and are primarily confined to lumen boundaries. We advocate for a shift in perspective towards recognizing vessel wall thickness measurement as inherently a 3D challenge and propose adapting the Laplacian method as an outstanding alternative. The Laplacian method is implemented using convolutions, ensuring its efficient and rapid execution on deep learning platforms. Experiments using digital phantoms and vessel wall imaging data are conducted to showcase the accuracy, reproducibility, and localization capabilities of the proposed approach. The proposed method produce consistent outcomes that remain independent of centerlines and 2D slices. Notably, this approach is applicable in both 2D and 3D scenarios. It allows for voxel-wise quantification of wall thickness, enabling precise identification of wall volumes exhibiting abnormal wall thickness. Our research highlights the urgency of transitioning to 3D methodologies for vessel wall thickness measurement. Such a transition not only acknowledges the intricate spatial variations of vessel walls, but also opens doors to more accurate, localized, and insightful diagnostic insights.
- Open Access
- 28 July 2023
- Published by Elsevier in NeuroImage: Clinical
- Vol. 39, 103483
Validation of deep learning techniques for quality augmentation in diffusion MRI for clinical studies
- 28 July 2023
- Published by Elsevier in NeuroImage: Clinical
- Vol. 39, 103483
Open AccessValidation of deep learning techniques for quality augmentation in diffusion MRI for clinical studies
- 5 December 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1141) , 20220222
A comparison of simultaneous multislice and conventional diffusion tensor imaging techniques for ischemic stroke evaluation at 1.5T
Objective: Diffusion tensor imaging (DTI) is a promising technique for ischemic stroke evaluation; however, acquisition time is longer than DWI. Simultaneous multislice (SMS) imaging acquires multiple slices together and reduces scan time. This study compared conventional and SMS DTI for ischemic stroke workup. Methods: Following IRB approval, the departmental stroke protocol was supplemented with SMS DTI on a clinical 1.5T MRI. Cases suspicious for ischemic stroke outside the treatment window were included. Standard DTI (STD-DTI, 20-direction, b = 2000 s/mm2), was followed by SMS-2-DTI (two slices simultaneously imaged). Two blinded neuroradiologists independently assessed image quality and DTI-trace status (positive/negative = stroke/other). Average image quality, interrater reliability (κ), receiver operating characteristic area under the curve (AUC), signal-to-noise ratio (SNR = DTI-source min/max/average), coefficient of variation (CV), mean diffusivity (MD), and fractional anisotropy (FA, of DTI-trace) were compared using two-tailed t-tests and a p < .05. Results: 41 patients were evaluated. SMS-2-DTI decreased DTI time by 132.17 ± 15.33 s, a 45% reduction. SMS-2-DTI reduced image quality (STD-DTI 4.7 ± 0.5 vs SMS-2-DTI 3.8 ± 0.6, p < .001). Diagnostic accuracy persisted, AUC was high for observer 1 (STD-DTI 0.95, 95%CI = 0.88–1.00 vs SMS-2-DTI 0.94, 95%CI = 0.87–1.00, p = .86) and observer 2 (STD-DTI 0.89, 95%CI = 0.79–0.99 vs SMS-2-DTI 0.86, 95%CI = 0.76–0.97, p = .66). Interrater reliability was high for STD-DTI (κ = 0.80, 95%CI = 0.61–0.98) and SMS-2-DTI (κ = 0.84, 95%CI = 0.67–1.00). SMS-2-DTI significantly decreased average SNR (STD-DTI 42.85 ± 4.44 vs SMS-2-DTI 32.58 ± 4.30, p < .001), and CV MD (STD-DTI 0.23 ± 0.03 vs 0.20 ± 0.04, p < .001). CV FA and CV DTI-trace were not statistically different. Conclusions: This study supports using SMS to accelerate DTI for ischemic stroke workup at 1.5T in the non-hyper-acute setting. Advances in knowledge: This study highlights the feasibility of accelerated multislice DTI for faster diagnostic DTI-trace images capable of ischemic stroke detection.
- 5 December 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1141) , 20220222
A comparison of simultaneous multislice and conventional diffusion tensor imaging techniques for ischemic stroke evaluation at 1.5T
Objective: Diffusion tensor imaging (DTI) is a promising technique for ischemic stroke evaluation; however, acquisition time is longer than DWI. Simultaneous multislice (SMS) imaging acquires multiple slices together and reduces scan time. This study compared conventional and SMS DTI for ischemic stroke workup. Methods: Following IRB approval, the departmental stroke protocol was supplemented with SMS DTI on a clinical 1.5T MRI. Cases suspicious for ischemic stroke outside the treatment window were included. Standard DTI (STD-DTI, 20-direction, b = 2000 s/mm2), was followed by SMS-2-DTI (two slices simultaneously imaged). Two blinded neuroradiologists independently assessed image quality and DTI-trace status (positive/negative = stroke/other). Average image quality, interrater reliability (κ), receiver operating characteristic area under the curve (AUC), signal-to-noise ratio (SNR = DTI-source min/max/average), coefficient of variation (CV), mean diffusivity (MD), and fractional anisotropy (FA, of DTI-trace) were compared using two-tailed t-tests and a p < .05. Results: 41 patients were evaluated. SMS-2-DTI decreased DTI time by 132.17 ± 15.33 s, a 45% reduction. SMS-2-DTI reduced image quality (STD-DTI 4.7 ± 0.5 vs SMS-2-DTI 3.8 ± 0.6, p < .001). Diagnostic accuracy persisted, AUC was high for observer 1 (STD-DTI 0.95, 95%CI = 0.88–1.00 vs SMS-2-DTI 0.94, 95%CI = 0.87–1.00, p = .86) and observer 2 (STD-DTI 0.89, 95%CI = 0.79–0.99 vs SMS-2-DTI 0.86, 95%CI = 0.76–0.97, p = .66). Interrater reliability was high for STD-DTI (κ = 0.80, 95%CI = 0.61–0.98) and SMS-2-DTI (κ = 0.84, 95%CI = 0.67–1.00). SMS-2-DTI significantly decreased average SNR (STD-DTI 42.85 ± 4.44 vs SMS-2-DTI 32.58 ± 4.30, p < .001), and CV MD (STD-DTI 0.23 ± 0.03 vs 0.20 ± 0.04, p < .001). CV FA and CV DTI-trace were not statistically different. Conclusions: This study supports using SMS to accelerate DTI for ischemic stroke workup at 1.5T in the non-hyper-acute setting. Advances in knowledge: This study highlights the feasibility of accelerated multislice DTI for faster diagnostic DTI-trace images capable of ischemic stroke detection.
- 10 March 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (5) , 661-669
Beyond Diffusion Tensor MRI Methods for Improved Characterization of the Brain after Ischemic Stroke: A Review
SUMMARY: Ischemic stroke is a worldwide problem, with 15 million people experiencing a stroke annually. MR imaging is a valuable tool for understanding and assessing brain changes after stroke and predicting recovery. Of particular interest is the use of diffusion MR imaging in the nonacute stage 1–30 days poststroke. Thousands of articles have been published on the use of diffusion MR imaging in stroke, including several recent articles reviewing the use of DTI for stroke. The goal of this work was to survey and put into context the recent use of diffusion MR imaging methods beyond DTI, including diffusional kurtosis, generalized fractional anisotropy, spherical harmonics methods, and neurite orientation and dispersion models, in patients poststroke. Early studies report that these types of beyond-DTI methods outperform DTI metrics either in being more sensitive to poststroke changes or by better predicting outcome motor scores. More and larger studies are needed to confirm the improved prediction of stroke recovery with the beyond-DTI methods.
- 10 March 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (5) , 661-669
Beyond Diffusion Tensor MRI Methods for Improved Characterization of the Brain after Ischemic Stroke: A Review
SUMMARY: Ischemic stroke is a worldwide problem, with 15 million people experiencing a stroke annually. MR imaging is a valuable tool for understanding and assessing brain changes after stroke and predicting recovery. Of particular interest is the use of diffusion MR imaging in the nonacute stage 1–30 days poststroke. Thousands of articles have been published on the use of diffusion MR imaging in stroke, including several recent articles reviewing the use of DTI for stroke. The goal of this work was to survey and put into context the recent use of diffusion MR imaging methods beyond DTI, including diffusional kurtosis, generalized fractional anisotropy, spherical harmonics methods, and neurite orientation and dispersion models, in patients poststroke. Early studies report that these types of beyond-DTI methods outperform DTI metrics either in being more sensitive to poststroke changes or by better predicting outcome motor scores. More and larger studies are needed to confirm the improved prediction of stroke recovery with the beyond-DTI methods.
- 26 January 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (6) , 2957-2971
Jointly estimating parametric maps of multiple diffusion models from undersampled q‐space data: A comparison of three deep learning approaches
Purpose While advanced diffusion techniques have been found valuable in many studies, their clinical availability has been hampered partly due to their long scan times. Moreover, each diffusion technique can only extract a few relevant microstructural features. Using multiple diffusion methods may help to better understand the brain microstructure, which requires multiple expensive model fittings. In this work, we compare deep learning (DL) approaches to jointly estimate parametric maps of multiple diffusion representations/models from highly undersampled q-space data. Methods We implement three DL approaches to jointly estimate parametric maps of diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), neurite orientation dispersion and density imaging (NODDI), and multi-compartment spherical mean technique (SMT). A per-voxel q-space deep learning (1D-qDL), a per-slice convolutional neural network (2D-CNN), and a 3D-patch-based microstructure estimation with sparse coding using a separable dictionary (MESC-SD) network are considered. Results The accuracy of estimated diffusion maps depends on the q-space undersampling, the selected network architecture, and the region and the parameter of interest. The smallest errors are observed for the MESC-SD network architecture (less than 10 normalized RMSE in most brain regions). Conclusion Our experiments show that DL methods are very efficient tools to simultaneously estimate several diffusion maps from undersampled q-space data. These methods can significantly reduce both the scan (6-fold) and processing times (25-fold) for estimating advanced parametric diffusion maps while achieving a reasonable accuracy.- 26 January 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (6) , 2957-2971
Jointly estimating parametric maps of multiple diffusion models from undersampled q‐space data: A comparison of three deep learning approaches
Purpose While advanced diffusion techniques have been found valuable in many studies, their clinical availability has been hampered partly due to their long scan times. Moreover, each diffusion technique can only extract a few relevant microstructural features. Using multiple diffusion methods may help to better understand the brain microstructure, which requires multiple expensive model fittings. In this work, we compare deep learning (DL) approaches to jointly estimate parametric maps of multiple diffusion representations/models from highly undersampled q-space data. Methods We implement three DL approaches to jointly estimate parametric maps of diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), neurite orientation dispersion and density imaging (NODDI), and multi-compartment spherical mean technique (SMT). A per-voxel q-space deep learning (1D-qDL), a per-slice convolutional neural network (2D-CNN), and a 3D-patch-based microstructure estimation with sparse coding using a separable dictionary (MESC-SD) network are considered. Results The accuracy of estimated diffusion maps depends on the q-space undersampling, the selected network architecture, and the region and the parameter of interest. The smallest errors are observed for the MESC-SD network architecture (less than 10 normalized RMSE in most brain regions). Conclusion Our experiments show that DL methods are very efficient tools to simultaneously estimate several diffusion maps from undersampled q-space data. These methods can significantly reduce both the scan (6-fold) and processing times (25-fold) for estimating advanced parametric diffusion maps while achieving a reasonable accuracy.- 1 May 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 70, 102000
Simultaneous multi-slice image reconstruction using regularized image domain split slice-GRAPPA for diffusion MRI
- 1 May 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 70, 102000
Simultaneous multi-slice image reconstruction using regularized image domain split slice-GRAPPA for diffusion MRI
- 1 February 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 66, 9-21
Coil-combined split slice-GRAPPA for simultaneous multi-slice diffusion MRI
- 1 February 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 66, 9-21
Coil-combined split slice-GRAPPA for simultaneous multi-slice diffusion MRI