Efficient and Accurate 3D Thickness Measurement in Vessel Wall Imaging: Overcoming Limitations of 2D Approaches Using the Laplacian Method
Open Access
- 15 August 2024
- journal article
- research article
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (8) , 249
Abstract
The clinical significance of measuring vessel wall thickness is widely acknowledged. Recent advancements have enabled high-resolution 3D scans of arteries and precise segmentation of their lumens and outer walls; however, most existing methods for assessing vessel wall thickness are 2D. Despite being valuable, reproducibility and accuracy of 2D techniques depend on the extracted 2D slices. Additionally, these methods fail to fully account for variations in wall thickness in all dimensions. Furthermore, most existing approaches are difficult to be extended into 3D and their measurements lack spatial localization and are primarily confined to lumen boundaries. We advocate for a shift in perspective towards recognizing vessel wall thickness measurement as inherently a 3D challenge and propose adapting the Laplacian method as an outstanding alternative. The Laplacian method is implemented using convolutions, ensuring its efficient and rapid execution on deep learning platforms. Experiments using digital phantoms and vessel wall imaging data are conducted to showcase the accuracy, reproducibility, and localization capabilities of the proposed approach. The proposed method produce consistent outcomes that remain independent of centerlines and 2D slices. Notably, this approach is applicable in both 2D and 3D scenarios. It allows for voxel-wise quantification of wall thickness, enabling precise identification of wall volumes exhibiting abnormal wall thickness. Our research highlights the urgency of transitioning to 3D methodologies for vessel wall thickness measurement. Such a transition not only acknowledges the intricate spatial variations of vessel walls, but also opens doors to more accurate, localized, and insightful diagnostic insights.Keywords
Funding Information
- 2023 Radiology Seed Grant at University of Utah (R01-NS127317, R01-HL103609)
- National Institutes of Health (R01-NS127317, R01-HL103609)
This publication has 37 references indexed in Scilit:
- Ex vivo vessel wall thickness measurements of the human circle of Willis using 7T MRIAtherosclerosis, 2018
- Interchangeable neck shape–specific coils for a clinically realizable anterior neck phased array systemMagnetic Resonance in Medicine, 2017
- Improved black‐blood imaging using DANTE‐SPACE for simultaneous carotid and intracranial vessel wall evaluationMagnetic Resonance in Medicine, 2015
- Intracranial arterial wall imaging using three‐dimensional high isotropic resolution black blood MRI at 3.0 TeslaJournal of Magnetic Resonance Imaging, 2011
- Carotid plaque assessment using fast 3D isotropic resolution black‐blood MRIMagnetic Resonance in Medicine, 2010
- Carotid intima-media thickness and distensibility measured by MRI at 3 T versus high-resolution ultrasoundEuropean Radiology, 2009
- On the overestimation of early wall thickening at the carotid bulb by black blood MRI, with implications for coronary and vulnerable plaque imagingMagnetic Resonance in Medicine, 2008
- Automatic vessel wall contour detection and quantification of wall thickness in in‐vivo MR images of the human aortaJournal of Magnetic Resonance Imaging, 2006
- Automated measurement of mean wall thickness in the common carotid artery by MRI: A comparison to intima‐media thickness by B‐mode ultrasoundJournal of Magnetic Resonance Imaging, 2006
- Three-dimensional mapping of cortical thickness using Laplace's EquationHuman Brain Mapping, 2000