Avraham Shitzer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Avraham Shitzer has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
David Degani
A Department of Mechanical Engineering , Technion, Israel Institute of Technology , Haifa , Israel
2 shared publications- Richard de Dear
The University of Sydney
2 shared publications Yael Ben Shabat
Department of Mechanical Engineering Technion, Israel Institute of Technology, Haifa, 32000, Israel
2 shared publicationsD. Degani
Department of Mechanical Engineering, Technion, Israel Institute of Technology, Haifa 32000, Israel
1 shared publicationDusan Fiala
Ergonsim, Stuttgart, Germany
1 shared publicationEdward Arens
Center for the Built Environment, University of California, Berkeley, CA, 94720, USA
1 shared publication
Latest Publications
- 11 February 2016
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 19 (13) , 1462-1474
An efficient technique for estimating the two-dimensional temperature distributions around multiple cryo-surgical probes based on combining contributions of unit circles
This study presents an efficient, fast and accurate method for estimating the two-dimensional temperature distributions around multiple cryo-surgical probes. The identical probes are inserted into the same depth and are operated simultaneously and uniformly. The first step in this method involves numerical derivation of the temporal performance data of a single probe, embedded in a semi-infinite, tissue-like medium. The results of this derivation are approximated by algebraic expressions that form the basis for computing the temperature distributions of multiple embedded probes by combining the data of a single probe. Comparison of isothermal contours derived by this method to those computed numerically for a variety of geometrical cases, up to 15 inserted probes and 2–10 min times of operation, yielded excellent results. Since this technique obviates the solution of the differential equations of multiple probes, the computational time required for a particular case is several orders of magnitude shorter than that needed for obtaining the full numerical solution. Blood perfusion and metabolic heat generation rates are demonstrated to inhibit the advancement of isothermal fronts. Application of this method will significantly shorten computational times without compromising the accuracy of the results. It may also facilitate expeditious consideration of the advantages of different modes of operation and the number of inserted probes at the early design stage.
- 11 February 2016
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 19 (13) , 1462-1474
An efficient technique for estimating the two-dimensional temperature distributions around multiple cryo-surgical probes based on combining contributions of unit circles
This study presents an efficient, fast and accurate method for estimating the two-dimensional temperature distributions around multiple cryo-surgical probes. The identical probes are inserted into the same depth and are operated simultaneously and uniformly. The first step in this method involves numerical derivation of the temporal performance data of a single probe, embedded in a semi-infinite, tissue-like medium. The results of this derivation are approximated by algebraic expressions that form the basis for computing the temperature distributions of multiple embedded probes by combining the data of a single probe. Comparison of isothermal contours derived by this method to those computed numerically for a variety of geometrical cases, up to 15 inserted probes and 2–10 min times of operation, yielded excellent results. Since this technique obviates the solution of the differential equations of multiple probes, the computational time required for a particular case is several orders of magnitude shorter than that needed for obtaining the full numerical solution. Blood perfusion and metabolic heat generation rates are demonstrated to inhibit the advancement of isothermal fronts. Application of this method will significantly shorten computational times without compromising the accuracy of the results. It may also facilitate expeditious consideration of the advantages of different modes of operation and the number of inserted probes at the early design stage.
- 5 November 2015
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 60 (7) , 1051-1064
Compilation of basal metabolic and blood perfusion rates in various multi-compartment, whole-body thermoregulation models
The assignments of basal metabolic rates (BMR), basal cardiac output (BCO), and basal blood perfusion rates (BBPR) were compared in nine multi-compartment, whole-body thermoregulation models. The data are presented at three levels of detail: total body, specific body regions, and regional body tissue layers. Differences in the assignment of these quantities among the compared models increased with the level of detail, in the above order. The ranges of variability in the total body BMR was 6.5 % relative to the lowest value, with a mean of 84.3 ± 2 W, and in the BCO, it was 8 % with a mean of 4.70 ± 0.13 l/min. The least variability among the body regions is seen in the combined torso (shoulders, thorax, and abdomen: ±7.8 % BMR and ±5.9 % BBPR) and in the combined head (head, face, and neck ±9.9 % BMR and ±10.9 % BBPR), determined by the ratio of the standard deviation to the mean. Much more variability is apparent in the extremities with the most showing in the BMR of the feet (±117 %), followed by the BBPR in the arms (±61.3 %). In the tissue layers, most of the bone layers were assigned zero BMR and BBPR, except in the shoulders and in the extremities that were assigned non-zero values in a number of models. The next lowest values were assigned to the fat layers, with occasional zero values. Skin basal values were invariably non-zero but involved very low values in certain models, e.g., BBPR in the feet and the hands. Muscle layers were invariably assigned high values with the highest found in the thorax, abdomen, and legs. The brain, lung, and viscera layers were assigned the highest of all values of both basal quantities with those of the brain layers showing rather tight ranges of variability in both basal quantities. Average basal values of the “time-seasoned” models presented in this study could be useful as a first step in future modeling efforts subject to appropriate adjustment of values to conform to most recently available and reliable data.
- 5 November 2015
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 60 (7) , 1051-1064
Compilation of basal metabolic and blood perfusion rates in various multi-compartment, whole-body thermoregulation models
The assignments of basal metabolic rates (BMR), basal cardiac output (BCO), and basal blood perfusion rates (BBPR) were compared in nine multi-compartment, whole-body thermoregulation models. The data are presented at three levels of detail: total body, specific body regions, and regional body tissue layers. Differences in the assignment of these quantities among the compared models increased with the level of detail, in the above order. The ranges of variability in the total body BMR was 6.5 % relative to the lowest value, with a mean of 84.3 ± 2 W, and in the BCO, it was 8 % with a mean of 4.70 ± 0.13 l/min. The least variability among the body regions is seen in the combined torso (shoulders, thorax, and abdomen: ±7.8 % BMR and ±5.9 % BBPR) and in the combined head (head, face, and neck ±9.9 % BMR and ±10.9 % BBPR), determined by the ratio of the standard deviation to the mean. Much more variability is apparent in the extremities with the most showing in the BMR of the feet (±117 %), followed by the BBPR in the arms (±61.3 %). In the tissue layers, most of the bone layers were assigned zero BMR and BBPR, except in the shoulders and in the extremities that were assigned non-zero values in a number of models. The next lowest values were assigned to the fat layers, with occasional zero values. Skin basal values were invariably non-zero but involved very low values in certain models, e.g., BBPR in the feet and the hands. Muscle layers were invariably assigned high values with the highest found in the thorax, abdomen, and legs. The brain, lung, and viscera layers were assigned the highest of all values of both basal quantities with those of the brain layers showing rather tight ranges of variability in both basal quantities. Average basal values of the “time-seasoned” models presented in this study could be useful as a first step in future modeling efforts subject to appropriate adjustment of values to conform to most recently available and reliable data.
- 10 June 2014
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 58 (6) , 1019-1020
Reply to comments by R. Osczevski on “Modified wind chill temperatures determined by a whole body thermoregulation model and human-based convective coefficients” by Ben Shabat, Shitzer, and Fiala (2013) and “Facial convective heat exchange coefficients in cold and windy environments estimated from human experiments” by Ben Shabat and Shitzer (2012)
- 10 June 2014
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 58 (6) , 1019-1020
Reply to comments by R. Osczevski on “Modified wind chill temperatures determined by a whole body thermoregulation model and human-based convective coefficients” by Ben Shabat, Shitzer, and Fiala (2013) and “Facial convective heat exchange coefficients in cold and windy environments estimated from human experiments” by Ben Shabat and Shitzer (2012)
- 28 June 2013
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 58 (6) , 1007-1015
Modified wind chill temperatures determined by a whole body thermoregulation model and human-based facial convective coefficients
- 28 June 2013
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 58 (6) , 1007-1015
Modified wind chill temperatures determined by a whole body thermoregulation model and human-based facial convective coefficients
- 4 July 2011
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 56 (4) , 639-651
Facial convective heat exchange coefficients in cold and windy environments estimated from human experiments
Facial heat exchange convection coefficients were estimated from experimental data in cold and windy ambient conditions applicable to wind chill calculations. Measured facial temperature datasets, that were made available to this study, originated from 3 separate studies involving 18 male and 6 female subjects. Most of these data were for a −10°C ambient environment and wind speeds in the range of 0.2 to 6 m s−1. Additional single experiments were for −5°C, 0°C and 10°C environments and wind speeds in the same range. Convection coefficients were estimated for all these conditions by means of a numerical facial heat exchange model, applying properties of biological tissues and a typical facial diameter of 0.18 m. Estimation was performed by adjusting the guessed convection coefficients in the computed facial temperatures, while comparing them to measured data, to obtain a satisfactory fit (r 2 > 0.98, in most cases). In one of the studies, heat flux meters were additionally used. Convection coefficients derived from these meters closely approached the estimated values for only the male subjects. They differed significantly, by about 50%, when compared to the estimated female subjects' data. Regression analysis was performed for just the −10°C ambient temperature, and the range of experimental wind speeds, due to the limited availability of data for other ambient temperatures. The regressed equation was assumed in the form of the equation underlying the “new” wind chill chart. Regressed convection coefficients, which closely duplicated the measured data, were consistently higher than those calculated by this equation, except for one single case. The estimated and currently used convection coefficients are shown to diverge exponentially from each other, as wind speed increases. This finding casts considerable doubts on the validity of the convection coefficients that are used in the computation of the "new" wind chill chart and their applicability to humans in cold and windy environments.
- 4 July 2011
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 56 (4) , 639-651
Facial convective heat exchange coefficients in cold and windy environments estimated from human experiments
Facial heat exchange convection coefficients were estimated from experimental data in cold and windy ambient conditions applicable to wind chill calculations. Measured facial temperature datasets, that were made available to this study, originated from 3 separate studies involving 18 male and 6 female subjects. Most of these data were for a −10°C ambient environment and wind speeds in the range of 0.2 to 6 m s−1. Additional single experiments were for −5°C, 0°C and 10°C environments and wind speeds in the same range. Convection coefficients were estimated for all these conditions by means of a numerical facial heat exchange model, applying properties of biological tissues and a typical facial diameter of 0.18 m. Estimation was performed by adjusting the guessed convection coefficients in the computed facial temperatures, while comparing them to measured data, to obtain a satisfactory fit (r 2 > 0.98, in most cases). In one of the studies, heat flux meters were additionally used. Convection coefficients derived from these meters closely approached the estimated values for only the male subjects. They differed significantly, by about 50%, when compared to the estimated female subjects' data. Regression analysis was performed for just the −10°C ambient temperature, and the range of experimental wind speeds, due to the limited availability of data for other ambient temperatures. The regressed equation was assumed in the form of the equation underlying the “new” wind chill chart. Regressed convection coefficients, which closely duplicated the measured data, were consistently higher than those calculated by this equation, except for one single case. The estimated and currently used convection coefficients are shown to diverge exponentially from each other, as wind speed increases. This finding casts considerable doubts on the validity of the convection coefficients that are used in the computation of the "new" wind chill chart and their applicability to humans in cold and windy environments.
- 27 September 2010
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (1) , 011005
Cryosurgery: Analysis and Experimentation of Cryoprobes in Phase Changing Media
This article presents a retrospective of work performed at the Technion, Israel Institute of Technology, over the last 3-odd decades. Results of analytical and numerical studies are presented briefly as well as in vitro and in vivo experimental data and their comparison to the derived results. Studies include the analysis of both the direct (Stefan) and the inverse-Stefan phase-change heat transfer problems in a tissue-simulating medium (gel) by the application of both surface and insertion cryoprobes. The effects of blood perfusion and metabolic heat generation rates on the advancement of the freezing front are discussed. The simultaneous operation of needle cryoprobes in a number of different configurations and the effects of a thermally significant blood vessel in the vicinity of the cryoprobe are also presented. Typical results demonstrate that metabolic rate in the yet nonfrozen tissue, will have only minor effects on the advancement of the frozen front. Capillary blood perfusion, on the other hand, does affect the course of change of the temperature distribution, hindering, as it is increased, the advancement of the frozen front. The volumes enclosed by the “lethal” isotherm (assumed as −40°C), achieve most of their final size in the first few minutes of operation, thus obviating the need for prolonged applications. Volumes occupied by this lethal isotherm were shown to be rather small. Thus, after 10 min of operation, these volumes will occupy only about 6% (single probe), 6–11% (two probes, varying distances apart), and 6–15% (three probes, different placement configurations), relative to the total frozen volume. For cryosurgery to become the treatment-of-choice, much more work will be required to cover the following issues: (1) A clear cut understanding and definition of the tissue-specific thermal conditions that are required to ensure the complete destruction of a tissue undergoing a controlled cryosurgical process. (2) Comprehensive analyses of the complete freeze/thaw cycle(s) and it effects on the final outcome. (3) Improved technical means to control the temperature variations of the cryoprobe to achieve the desired thermal conditions required for tissue destruction. (4) Improvement in the pretreatment design process to include optimal placement schemes of multiprobes and their separate and specific operation. (5) Understanding the effects of thermally significant blood vessels, and other related thermal perturbations, which are situated adjacent to, or even within, the tissue volume to be treated.
- 27 September 2010
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (1) , 011005
Cryosurgery: Analysis and Experimentation of Cryoprobes in Phase Changing Media
This article presents a retrospective of work performed at the Technion, Israel Institute of Technology, over the last 3-odd decades. Results of analytical and numerical studies are presented briefly as well as in vitro and in vivo experimental data and their comparison to the derived results. Studies include the analysis of both the direct (Stefan) and the inverse-Stefan phase-change heat transfer problems in a tissue-simulating medium (gel) by the application of both surface and insertion cryoprobes. The effects of blood perfusion and metabolic heat generation rates on the advancement of the freezing front are discussed. The simultaneous operation of needle cryoprobes in a number of different configurations and the effects of a thermally significant blood vessel in the vicinity of the cryoprobe are also presented. Typical results demonstrate that metabolic rate in the yet nonfrozen tissue, will have only minor effects on the advancement of the frozen front. Capillary blood perfusion, on the other hand, does affect the course of change of the temperature distribution, hindering, as it is increased, the advancement of the frozen front. The volumes enclosed by the “lethal” isotherm (assumed as −40°C), achieve most of their final size in the first few minutes of operation, thus obviating the need for prolonged applications. Volumes occupied by this lethal isotherm were shown to be rather small. Thus, after 10 min of operation, these volumes will occupy only about 6% (single probe), 6–11% (two probes, varying distances apart), and 6–15% (three probes, different placement configurations), relative to the total frozen volume. For cryosurgery to become the treatment-of-choice, much more work will be required to cover the following issues: (1) A clear cut understanding and definition of the tissue-specific thermal conditions that are required to ensure the complete destruction of a tissue undergoing a controlled cryosurgical process. (2) Comprehensive analyses of the complete freeze/thaw cycle(s) and it effects on the final outcome. (3) Improved technical means to control the temperature variations of the cryoprobe to achieve the desired thermal conditions required for tissue destruction. (4) Improvement in the pretreatment design process to include optimal placement schemes of multiprobes and their separate and specific operation. (5) Understanding the effects of thermally significant blood vessels, and other related thermal perturbations, which are situated adjacent to, or even within, the tissue volume to be treated.
- 18 September 2010
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 56 (3) , 495-503
Advances, shortcomings, and recommendations for wind chill estimation
This article discusses briefly the advances made and the remaining short-comings in the "new" wind chill charts adopted in the US and Canada in 2001. A number of indicated refinements are proposed, including the use of whole body models in the computations, verification of heat exchange coefficients by human experiments, reconsideration of "calm" wind conditions, reconsideration of frostbite threshold levels, the inclusion of cold-related pain and numbness in the charts, etc. A dynamic numerical model is applied to compare the effects of wind speeds, on the one hand, and air temperatures, on the other, on the steady-state exposed facial and bare finger temperatures. An apparent asymmetry is demonstrated, favoring the effects of wind speeds over those of air temperatures for an identical final facial temperature. This asymmetry is reversed, however, when SI unit changes in these quantities are considered.
- 18 September 2010
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 56 (3) , 495-503
Advances, shortcomings, and recommendations for wind chill estimation
This article discusses briefly the advances made and the remaining short-comings in the "new" wind chill charts adopted in the US and Canada in 2001. A number of indicated refinements are proposed, including the use of whole body models in the computations, verification of heat exchange coefficients by human experiments, reconsideration of "calm" wind conditions, reconsideration of frostbite threshold levels, the inclusion of cold-related pain and numbness in the charts, etc. A dynamic numerical model is applied to compare the effects of wind speeds, on the one hand, and air temperatures, on the other, on the steady-state exposed facial and bare finger temperatures. An apparent asymmetry is demonstrated, favoring the effects of wind speeds over those of air temperatures for an identical final facial temperature. This asymmetry is reversed, however, when SI unit changes in these quantities are considered.
- 20 March 2009
- Published by Wiley in Journal of Heat Transfer
- Vol. 131 (5) , 051101
Numerical Simulation of the Effects of a Thermally Significant Blood Vessel on Freezing by a Circular Surface Cryosurgical Probe Compared With Experimental Data
The dynamic thermal interaction between a surface cryosurgical probe (heat sink) and an embedded cylindrical tube (heat source), simulating a thermally-significant blood vessel, has been studied. The cryoprobe was operated by liquid nitrogen while the embedded tube was perfused by water at a constant inlet temperature. Previous experimental data were obtained in a phase-changing medium (PCM) made of 30%/70% by volume mashed potato flakes/distilled-water solution. A parametric study was conducted without the embedded tube, and with flow rates of 30 ml/min and 100 ml/min in the tube, while cooling rates at the tip of the cryoprobe were maintained at −4°C/min, −8°C/min, or −12°C/min. Numerical thermal analysis was performed by ANSYS7.0 and showed good conformity to the experimental data. The results quantify the effects of these parameters on both the shape and extent of freezing obtained in the PCM. For 20 min of operation of the cryoprobe, water temperatures inside the tube remained well above the freezing point for all assumed operating conditions. Frozen volumes of the 0°C isotherm, approximating the “frozen front,” and the −40°C isotherm, representing the “lethal temperature,” were smallest for the combination of highest cooling rate at the cryoprobe and the highest flow rate in the tube, (−12°C/min and 100 ml/min). The results indicate that both the flow rates in the embedded tube, and the cooling rates applied at the cryoprobe, have similar qualitative effects on the size of the PCM frozen volumes; increasing either one will cause these volumes to decrease. Under the conditions of this study the effects of flow rate in the tube are more pronounced, however, effecting relative frozen volumes decreases by about 10–20% while those of the cooling rate at the cryoprobe are in the range of 7–14%.
- 20 March 2009
- Published by Wiley in Journal of Heat Transfer
- Vol. 131 (5) , 051101
Numerical Simulation of the Effects of a Thermally Significant Blood Vessel on Freezing by a Circular Surface Cryosurgical Probe Compared With Experimental Data
The dynamic thermal interaction between a surface cryosurgical probe (heat sink) and an embedded cylindrical tube (heat source), simulating a thermally-significant blood vessel, has been studied. The cryoprobe was operated by liquid nitrogen while the embedded tube was perfused by water at a constant inlet temperature. Previous experimental data were obtained in a phase-changing medium (PCM) made of 30%/70% by volume mashed potato flakes/distilled-water solution. A parametric study was conducted without the embedded tube, and with flow rates of 30 ml/min and 100 ml/min in the tube, while cooling rates at the tip of the cryoprobe were maintained at −4°C/min, −8°C/min, or −12°C/min. Numerical thermal analysis was performed by ANSYS7.0 and showed good conformity to the experimental data. The results quantify the effects of these parameters on both the shape and extent of freezing obtained in the PCM. For 20 min of operation of the cryoprobe, water temperatures inside the tube remained well above the freezing point for all assumed operating conditions. Frozen volumes of the 0°C isotherm, approximating the “frozen front,” and the −40°C isotherm, representing the “lethal temperature,” were smallest for the combination of highest cooling rate at the cryoprobe and the highest flow rate in the tube, (−12°C/min and 100 ml/min). The results indicate that both the flow rates in the embedded tube, and the cooling rates applied at the cryoprobe, have similar qualitative effects on the size of the PCM frozen volumes; increasing either one will cause these volumes to decrease. Under the conditions of this study the effects of flow rate in the tube are more pronounced, however, effecting relative frozen volumes decreases by about 10–20% while those of the cooling rate at the cryoprobe are in the range of 7–14%.
- Open Access
- 1 October 2008
- Published by American Meteorological Society in Journal of Applied Meteorology and Climatology
- Vol. 47 (10) , 2739-2740
Reply
- 1 October 2008
- Published by American Meteorological Society in Journal of Applied Meteorology and Climatology
- Vol. 47 (10) , 2739-2740
Open AccessReply
- 1 March 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (3) , 032301
Experimental and Numerical Study of One, Two, and Three Embedded Needle Cryoprobes Simultaneously Operated by High Pressure Argon Gas
One, two, and three needle cryoprobes, 1.47mm outside diameter, simultaneously and uniformly operated by high pressure argon gas, were tested in a gel simulating the thermal properties of biological tissues. The probes were inserted into the same depth in the gel through two parallel templates with holes drilled on a 5×5mm2 mesh. The temperature of the active segment of the probe was monitored by a single soldered thermocouple (TC). Temperatures in the gel were monitored by K-type TC strings in the radial, and in the downward and upward axial directions. The phase-change problem in the gel was solved by ANSYS7.0, based on the enthalpy method. Calculated and measured results compared reasonably well with the most deviations observed in the upward axial direction. Results of this study may be summarized as follows: (a) Due to the cylindrical structure of the probe, the advancement of the frozen fronts was more pronounced in the upward axial and the radial directions than in the downward direction. (b) The farthest placement of the two probes (10mm) yielded the largest volumes enclosed by the isothermal contours. (c) In the tightest two placement configurations of the three probes, the −40°C fronts of all frozen lumps have joined together even after 1min of operation, while in the less tight configurations, joining occurred later. (d) In multiprobe applications and for a given duration of application, there exists a certain placement configuration that will produce the maximal volume of any temperature-specific frozen lump. The computational tool presented in this study could assist the surgeon in the preplanning of cryosurgical procedures and thus reduce uncertainties and enhance its success rate.
- 1 March 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (3) , 032301
Experimental and Numerical Study of One, Two, and Three Embedded Needle Cryoprobes Simultaneously Operated by High Pressure Argon Gas
One, two, and three needle cryoprobes, 1.47mm outside diameter, simultaneously and uniformly operated by high pressure argon gas, were tested in a gel simulating the thermal properties of biological tissues. The probes were inserted into the same depth in the gel through two parallel templates with holes drilled on a 5×5mm2 mesh. The temperature of the active segment of the probe was monitored by a single soldered thermocouple (TC). Temperatures in the gel were monitored by K-type TC strings in the radial, and in the downward and upward axial directions. The phase-change problem in the gel was solved by ANSYS7.0, based on the enthalpy method. Calculated and measured results compared reasonably well with the most deviations observed in the upward axial direction. Results of this study may be summarized as follows: (a) Due to the cylindrical structure of the probe, the advancement of the frozen fronts was more pronounced in the upward axial and the radial directions than in the downward direction. (b) The farthest placement of the two probes (10mm) yielded the largest volumes enclosed by the isothermal contours. (c) In the tightest two placement configurations of the three probes, the −40°C fronts of all frozen lumps have joined together even after 1min of operation, while in the less tight configurations, joining occurred later. (d) In multiprobe applications and for a given duration of application, there exists a certain placement configuration that will produce the maximal volume of any temperature-specific frozen lump. The computational tool presented in this study could assist the surgeon in the preplanning of cryosurgical procedures and thus reduce uncertainties and enhance its success rate.