Xiaocong Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaocong Li has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Junhua Xu
Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
3 shared publications - Xuanren Meng
College of Electrical Engineering, Guangxi University, Nanning, CO 530004 China
2 shared publications - Ali Mustafa
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Chunwei Wang
College of Electrical Engineering, Guangxi University, Nanning 530004, China
1 shared publication Dengyi Chen
College of Electrical Engineering Guangxi University Nanning 530004 Guangxi Zhuang Autonomous Region China
1 shared publication- Ermeng Zeng
College of Electrical Engineering, Guangxi University, Nanning 530004, China
1 shared publication
Latest Publications
- Open Access
- 12 April 2025
- Published by MDPI AG in Fractal and Fractional
- Vol. 9 (4) , 244
Mechanism Modeling and Analysis of Fractional-Order Synchronous Generator
This paper investigates the fractional-order characteristics of the stator and rotor windings of a synchronous generator. Utilizing mechanism-based modeling methodology, it pioneers the derivation of the fractional-order voltage equations for a synchronous generator across both the three-phase stationary coordinate system (A, B, C) and the synchronous rotating coordinate system (d, q, 0). Through simplifying assumptions and rigorous derivations, a 2 + α (α ∈ (0, 2)) order synchronous generator model is formulated. This paper develops a digital simulation model of a fractional-order single-machine infinite bus system and analyzes the impact of the order α on the synchronous generator system’s dynamic performance through disturbance simulation experiments. Experimental results demonstrate that under conventional disturbances, increasing α from 0.8 to 1.2 reduces the system oscillation period and frequency while enhancing mechanical oscillation suppression, whereas decreasing α to 0.8 accelerates the generator terminal voltage response, lowers electromagnetic power overshoot, and improves excitation control effectiveness.
- 12 April 2025
- Published by MDPI AG in Fractal and Fractional
- Vol. 9 (4) , 244
Open AccessMechanism Modeling and Analysis of Fractional-Order Synchronous Generator
This paper investigates the fractional-order characteristics of the stator and rotor windings of a synchronous generator. Utilizing mechanism-based modeling methodology, it pioneers the derivation of the fractional-order voltage equations for a synchronous generator across both the three-phase stationary coordinate system (A, B, C) and the synchronous rotating coordinate system (d, q, 0). Through simplifying assumptions and rigorous derivations, a 2 + α (α ∈ (0, 2)) order synchronous generator model is formulated. This paper develops a digital simulation model of a fractional-order single-machine infinite bus system and analyzes the impact of the order α on the synchronous generator system’s dynamic performance through disturbance simulation experiments. Experimental results demonstrate that under conventional disturbances, increasing α from 0.8 to 1.2 reduces the system oscillation period and frequency while enhancing mechanical oscillation suppression, whereas decreasing α to 0.8 accelerates the generator terminal voltage response, lowers electromagnetic power overshoot, and improves excitation control effectiveness.
- Open Access
- 5 January 2024
- Published by MDPI AG in Fractal and Fractional
- Vol. 8 (1) , 38
Fractional-Order LCL Filters: Principle, Frequency Characteristics, and Their Analysis
The fractional-order LCL filter, composed of two fractional-order inductors and one fractional-order capacitor, is a novel fractional-order π-type circuit introduced in recent years. Based on mathematical modeling, this article comprehensively studies the principles and frequency characteristics of fractional-order LCL filters. Five critical properties are derived and rigorously demonstrated. One of the most significant findings is that we identify the necessary and sufficient condition for resonance in fractional-order LCL filters when the sum of the orders of the fractional-order inductors and the fractional-order capacitor is equal to 2, which provides a theoretical foundation for effectively avoiding resonance in fractional-order LCL filters. The correctness of our theoretical derivation and analysis was confirmed through digital simulations. This study reveals that fractional-order LCL filters exhibit more versatile operational characteristics than traditional integer-order LCL filters, paving the way for broader application prospects.
- 5 January 2024
- Published by MDPI AG in Fractal and Fractional
- Vol. 8 (1) , 38
Open AccessFractional-Order LCL Filters: Principle, Frequency Characteristics, and Their Analysis
The fractional-order LCL filter, composed of two fractional-order inductors and one fractional-order capacitor, is a novel fractional-order π-type circuit introduced in recent years. Based on mathematical modeling, this article comprehensively studies the principles and frequency characteristics of fractional-order LCL filters. Five critical properties are derived and rigorously demonstrated. One of the most significant findings is that we identify the necessary and sufficient condition for resonance in fractional-order LCL filters when the sum of the orders of the fractional-order inductors and the fractional-order capacitor is equal to 2, which provides a theoretical foundation for effectively avoiding resonance in fractional-order LCL filters. The correctness of our theoretical derivation and analysis was confirmed through digital simulations. This study reveals that fractional-order LCL filters exhibit more versatile operational characteristics than traditional integer-order LCL filters, paving the way for broader application prospects.
- Open Access
Application of Underdetermined Blind Source Separation Algorithm on the Low-Frequency Oscillation in Power Systems
The timely discovery of low-frequency oscillations in power systems and accurate identification of their modal parameters is critical in numerous applications. Therefore, we investigated the feasibility of using multi-channel signals and established a relative theory. An algorithm based on the underdetermined blind source separation (UBSS) algorithm was proposed using this theory. First, the energy ratio function was used to determine the fault occurrence time. Then, the Bayesian information criterion was used to estimate the number of fault sources, and the boundary conditions were set to determine the number of fault sources. Next, the UBSS algorithm was used to analyze raw data, extract individual components that characterize faults, and subsequently measure low-frequency oscillation modal parameters through the Hilbert transform. Finally, the fast independent component analysis (FastICA) algorithm was used to separate noise signal from raw data. This separation considerably reduced noise disturbance and ensured the stability of the proposed method. Model simulation was conducted in MATLAB and experimental measurement revealed that the proposed method effectively reduced noise disturbance and could be applied to conditions with considerable disturbance.
Open AccessApplication of Underdetermined Blind Source Separation Algorithm on the Low-Frequency Oscillation in Power Systems
The timely discovery of low-frequency oscillations in power systems and accurate identification of their modal parameters is critical in numerous applications. Therefore, we investigated the feasibility of using multi-channel signals and established a relative theory. An algorithm based on the underdetermined blind source separation (UBSS) algorithm was proposed using this theory. First, the energy ratio function was used to determine the fault occurrence time. Then, the Bayesian information criterion was used to estimate the number of fault sources, and the boundary conditions were set to determine the number of fault sources. Next, the UBSS algorithm was used to analyze raw data, extract individual components that characterize faults, and subsequently measure low-frequency oscillation modal parameters through the Hilbert transform. Finally, the fast independent component analysis (FastICA) algorithm was used to separate noise signal from raw data. This separation considerably reduced noise disturbance and ensured the stability of the proposed method. Model simulation was conducted in MATLAB and experimental measurement revealed that the proposed method effectively reduced noise disturbance and could be applied to conditions with considerable disturbance.
- 1 February 2022
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 17 (5) , 637-645
Study on torsional vibration suppression effect of double‐ended driving turbo‐generator shafting structure
- 1 February 2022
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 17 (5) , 637-645
Study on torsional vibration suppression effect of double‐ended driving turbo‐generator shafting structure
- Open Access
Metaheuristic Based Solution for the Non‐Linear Controller of the Multiterminal High‐Voltage Direct Current Networks
The purpose of this study is to improve the P-I controllers of the voltage-source converters (VSC)-based multiterminal high voltage direct-current (MT-HVDC) networks. Since the VSCs are the non-linear elements of the MT-HVDC stations, the classical optimization methods, which approximately implement the linear model to optimize the P-I controllers of the VSCs, do not generate optimal results. Therefore, this paper presents a novel technique to optimize the VSC-based MT-HVDC grids’ P-I controllers by embedding the artificial bee colony (ABC) algorithm. The voltage-droop control method is employed at on-shore grids to ensure the active and reactive power balance within MT-HVDC networks. During an evaluation, achieved via a detailed four-terminal MT-HVDC model designed in PSCAD/EMTDC, the improved results obtained under different dynamic situations such as unbalance wind power generation, change in load demand at the on-shore side grids, and eventual VSC disconnection, respectively.
Open AccessMetaheuristic Based Solution for the Non‐Linear Controller of the Multiterminal High‐Voltage Direct Current Networks
The purpose of this study is to improve the P-I controllers of the voltage-source converters (VSC)-based multiterminal high voltage direct-current (MT-HVDC) networks. Since the VSCs are the non-linear elements of the MT-HVDC stations, the classical optimization methods, which approximately implement the linear model to optimize the P-I controllers of the VSCs, do not generate optimal results. Therefore, this paper presents a novel technique to optimize the VSC-based MT-HVDC grids’ P-I controllers by embedding the artificial bee colony (ABC) algorithm. The voltage-droop control method is employed at on-shore grids to ensure the active and reactive power balance within MT-HVDC networks. During an evaluation, achieved via a detailed four-terminal MT-HVDC model designed in PSCAD/EMTDC, the improved results obtained under different dynamic situations such as unbalance wind power generation, change in load demand at the on-shore side grids, and eventual VSC disconnection, respectively.
- Open Access
A Multi-Index Feedback Linearization Control for a Buck-Boost Converter
Due to the nonlinear and nonminimum phase characteristics of the buck-boost converter, the design of its controller has always been a challenging problem. In this paper, a multi-index feedback linearization control strategy is proposed to design the controller of the buck-boost converter. Firstly, by constructing an appropriate output function, the original nonlinear system is mapped into a combination of a linear subsystem and a nonlinear subsystem. Then, according to the structural characteristics of these two subsystems, the linear optimal control theory is adopted for the control design of the linear subsystem to make it have a good output performance, while for the nonlinear subsystem, the coefficient of the output function is adjusted to ensure its stability. Finally, based on the Hartman–Grobman theorem, the internal mechanism and coefficient adjustment basis of the proposed method are revealed; that is, by adjusting the coefficient of the output function and the feedback coefficient of the linear control law, the poles of the system are configured to achieve the purpose of adjusting the static and dynamic performance of the system. The simulation results show the feasibility and superiority of using the multi-index feedback linearization control strategy to design the nonlinear control law of the buck-boost converter.
Open AccessA Multi-Index Feedback Linearization Control for a Buck-Boost Converter
Due to the nonlinear and nonminimum phase characteristics of the buck-boost converter, the design of its controller has always been a challenging problem. In this paper, a multi-index feedback linearization control strategy is proposed to design the controller of the buck-boost converter. Firstly, by constructing an appropriate output function, the original nonlinear system is mapped into a combination of a linear subsystem and a nonlinear subsystem. Then, according to the structural characteristics of these two subsystems, the linear optimal control theory is adopted for the control design of the linear subsystem to make it have a good output performance, while for the nonlinear subsystem, the coefficient of the output function is adjusted to ensure its stability. Finally, based on the Hartman–Grobman theorem, the internal mechanism and coefficient adjustment basis of the proposed method are revealed; that is, by adjusting the coefficient of the output function and the feedback coefficient of the linear control law, the poles of the system are configured to achieve the purpose of adjusting the static and dynamic performance of the system. The simulation results show the feasibility and superiority of using the multi-index feedback linearization control strategy to design the nonlinear control law of the buck-boost converter.
- Open Access
- 9 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 13507-13515
Fractional-Order Modeling and Analysis of a Three-Phase Voltage Source PWM Rectifier
In this paper, the fractional-order modeling and analysis of a three-phase voltage source PWM rectifier (VSR) are researched considering the fractional-order characteristics of actual inductors and capacitors. While the Caputo fractional calculus operator is used to describe the fractional-order characteristics of an inductor and a capacitor, the fractional-order model of a three-phase VSR is established in the three-phase static coordinate system. With the coordinate transformation, the fractional-order model is expressed in the two-phase static coordinate system and in the synchronous rotation coordinate system, respectively. Simulation results verify the effectiveness of the established models, and indicate that the fractional-order models can describe the operating characteristics of a three-phase VSR more accurately. Besides, compared with the traditional integer-order three-phase VSRs, the three-phase VSRs which contain the fractional-order inductors and the fractional-order capacitor can present better static and dynamic performance indexes (such as smaller overshoot and shorter regulation time) by appropriately selecting the orders of the inductors and the capacitor.
- 9 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 13507-13515
Open AccessFractional-Order Modeling and Analysis of a Three-Phase Voltage Source PWM Rectifier
In this paper, the fractional-order modeling and analysis of a three-phase voltage source PWM rectifier (VSR) are researched considering the fractional-order characteristics of actual inductors and capacitors. While the Caputo fractional calculus operator is used to describe the fractional-order characteristics of an inductor and a capacitor, the fractional-order model of a three-phase VSR is established in the three-phase static coordinate system. With the coordinate transformation, the fractional-order model is expressed in the two-phase static coordinate system and in the synchronous rotation coordinate system, respectively. Simulation results verify the effectiveness of the established models, and indicate that the fractional-order models can describe the operating characteristics of a three-phase VSR more accurately. Besides, compared with the traditional integer-order three-phase VSRs, the three-phase VSRs which contain the fractional-order inductors and the fractional-order capacitor can present better static and dynamic performance indexes (such as smaller overshoot and shorter regulation time) by appropriately selecting the orders of the inductors and the capacitor.
- Open Access
- 13 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 165345-165355
An Instantaneous Frequency Identification Algorithm for Time-Varying Frequency Signals
A high-precision instantaneous frequency (IF) identification algorithm is proposed in this paper. The algorithm is based on the relationship between the signal phase and time, and uses Taylor’s expansion to parameterize the time-varying frequency. It can accurately identify the IF of various frequency-modulated (FM) signals. The simulation results show that high identification precision can be obtained when the frequency of the signal is stable or modulated by linear and nonlinear functions. Compared to the conventional IF identification algorithms Hilbert transform (HT) and Wigner-Ville distribution (WVD), the proposed algorithm performs better in accuracy. Besides, the proposed algorithm is not sensitive to the amplitude-modulation behavior, and it shows better precision than the Direct Quadrature (DQ) algorithm, which is an IF identification algorithm of the amplitude-modulated signal. The calculation amount of the proposed algorithm is not related to the sampling rate. Increasing the sampling rate can make the identification precision higher without changing the calculation speed. It can provide the theoretical basis for the IF identification of a grid-connected inverter and other automatic devices in the power system.
- 13 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 165345-165355
Open AccessAn Instantaneous Frequency Identification Algorithm for Time-Varying Frequency Signals
A high-precision instantaneous frequency (IF) identification algorithm is proposed in this paper. The algorithm is based on the relationship between the signal phase and time, and uses Taylor’s expansion to parameterize the time-varying frequency. It can accurately identify the IF of various frequency-modulated (FM) signals. The simulation results show that high identification precision can be obtained when the frequency of the signal is stable or modulated by linear and nonlinear functions. Compared to the conventional IF identification algorithms Hilbert transform (HT) and Wigner-Ville distribution (WVD), the proposed algorithm performs better in accuracy. Besides, the proposed algorithm is not sensitive to the amplitude-modulation behavior, and it shows better precision than the Direct Quadrature (DQ) algorithm, which is an IF identification algorithm of the amplitude-modulated signal. The calculation amount of the proposed algorithm is not related to the sampling rate. Increasing the sampling rate can make the identification precision higher without changing the calculation speed. It can provide the theoretical basis for the IF identification of a grid-connected inverter and other automatic devices in the power system.
- 18 November 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 14 (3) , 366-375
Wide‐area‐signals‐based nonlinear excitation control in multi‐machine power systems
- 18 November 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 14 (3) , 366-375
Wide‐area‐signals‐based nonlinear excitation control in multi‐machine power systems
- 25 February 2016
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 94 (6) , 1184-1190
Vapour phase selective oxidation of 2‐methylnaphthalene to 2‐methyl‐1,4‐naphthoquinone on composite vanadium catalyst
The selective vapour‐phase oxidation of 2‐MN to 2‐MNQ was investigated effectively in the presence of a composite vanadium catalyst. The catalyst was prepared by impregnation. It was characterized by XRD, BET, SEM, etc. The activity of the catalyst was tested in a fixed bed reactor by the selective oxidation of 2‐MN to 2‐MNQ, and the process conditions were optimized. The proper reaction temperature was 663 K, the space velocity was 200 mL · (g · min)−1, and the material flow was 3 μL · min−1. The 2‐MN conversion rate was 80.01 %, and the yield of 2‐MNQ was 45.84 %. Compared to previous procedures for this type of reaction, the reaction is more environmentally friendly and is suitable for large‐scale industrial production.
- 25 February 2016
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 94 (6) , 1184-1190
Vapour phase selective oxidation of 2‐methylnaphthalene to 2‐methyl‐1,4‐naphthoquinone on composite vanadium catalyst
The selective vapour‐phase oxidation of 2‐MN to 2‐MNQ was investigated effectively in the presence of a composite vanadium catalyst. The catalyst was prepared by impregnation. It was characterized by XRD, BET, SEM, etc. The activity of the catalyst was tested in a fixed bed reactor by the selective oxidation of 2‐MN to 2‐MNQ, and the process conditions were optimized. The proper reaction temperature was 663 K, the space velocity was 200 mL · (g · min)−1, and the material flow was 3 μL · min−1. The 2‐MN conversion rate was 80.01 %, and the yield of 2‐MNQ was 45.84 %. Compared to previous procedures for this type of reaction, the reaction is more environmentally friendly and is suitable for large‐scale industrial production.