Xuanren Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuanren Meng has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Junhua Xu
Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
2 shared publications - Xiaocong Li
College of Electrical Engineering, Guangxi University, Nanning 530004, China
2 shared publications Hui Liu
1 shared publication- Hui Liu
School of Electrical Engineering, Guangxi University, Nanning 530004, China
1 shared publication Jianbo Qin
1 shared publicationXiaocong Li
1 shared publication
Latest Publications
- 1 December 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 479
Modeling and analysis of a single-phase fractional-order voltage source pulse width modulation rectifier
- 1 December 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 479
Modeling and analysis of a single-phase fractional-order voltage source pulse width modulation rectifier
- Open Access
- 9 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 13507-13515
Fractional-Order Modeling and Analysis of a Three-Phase Voltage Source PWM Rectifier
In this paper, the fractional-order modeling and analysis of a three-phase voltage source PWM rectifier (VSR) are researched considering the fractional-order characteristics of actual inductors and capacitors. While the Caputo fractional calculus operator is used to describe the fractional-order characteristics of an inductor and a capacitor, the fractional-order model of a three-phase VSR is established in the three-phase static coordinate system. With the coordinate transformation, the fractional-order model is expressed in the two-phase static coordinate system and in the synchronous rotation coordinate system, respectively. Simulation results verify the effectiveness of the established models, and indicate that the fractional-order models can describe the operating characteristics of a three-phase VSR more accurately. Besides, compared with the traditional integer-order three-phase VSRs, the three-phase VSRs which contain the fractional-order inductors and the fractional-order capacitor can present better static and dynamic performance indexes (such as smaller overshoot and shorter regulation time) by appropriately selecting the orders of the inductors and the capacitor.
- 9 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 13507-13515
Open AccessFractional-Order Modeling and Analysis of a Three-Phase Voltage Source PWM Rectifier
In this paper, the fractional-order modeling and analysis of a three-phase voltage source PWM rectifier (VSR) are researched considering the fractional-order characteristics of actual inductors and capacitors. While the Caputo fractional calculus operator is used to describe the fractional-order characteristics of an inductor and a capacitor, the fractional-order model of a three-phase VSR is established in the three-phase static coordinate system. With the coordinate transformation, the fractional-order model is expressed in the two-phase static coordinate system and in the synchronous rotation coordinate system, respectively. Simulation results verify the effectiveness of the established models, and indicate that the fractional-order models can describe the operating characteristics of a three-phase VSR more accurately. Besides, compared with the traditional integer-order three-phase VSRs, the three-phase VSRs which contain the fractional-order inductors and the fractional-order capacitor can present better static and dynamic performance indexes (such as smaller overshoot and shorter regulation time) by appropriately selecting the orders of the inductors and the capacitor.
- Open Access
- 13 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 165345-165355
An Instantaneous Frequency Identification Algorithm for Time-Varying Frequency Signals
A high-precision instantaneous frequency (IF) identification algorithm is proposed in this paper. The algorithm is based on the relationship between the signal phase and time, and uses Taylor’s expansion to parameterize the time-varying frequency. It can accurately identify the IF of various frequency-modulated (FM) signals. The simulation results show that high identification precision can be obtained when the frequency of the signal is stable or modulated by linear and nonlinear functions. Compared to the conventional IF identification algorithms Hilbert transform (HT) and Wigner-Ville distribution (WVD), the proposed algorithm performs better in accuracy. Besides, the proposed algorithm is not sensitive to the amplitude-modulation behavior, and it shows better precision than the Direct Quadrature (DQ) algorithm, which is an IF identification algorithm of the amplitude-modulated signal. The calculation amount of the proposed algorithm is not related to the sampling rate. Increasing the sampling rate can make the identification precision higher without changing the calculation speed. It can provide the theoretical basis for the IF identification of a grid-connected inverter and other automatic devices in the power system.
- 13 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 165345-165355
Open AccessAn Instantaneous Frequency Identification Algorithm for Time-Varying Frequency Signals
A high-precision instantaneous frequency (IF) identification algorithm is proposed in this paper. The algorithm is based on the relationship between the signal phase and time, and uses Taylor’s expansion to parameterize the time-varying frequency. It can accurately identify the IF of various frequency-modulated (FM) signals. The simulation results show that high identification precision can be obtained when the frequency of the signal is stable or modulated by linear and nonlinear functions. Compared to the conventional IF identification algorithms Hilbert transform (HT) and Wigner-Ville distribution (WVD), the proposed algorithm performs better in accuracy. Besides, the proposed algorithm is not sensitive to the amplitude-modulation behavior, and it shows better precision than the Direct Quadrature (DQ) algorithm, which is an IF identification algorithm of the amplitude-modulated signal. The calculation amount of the proposed algorithm is not related to the sampling rate. Increasing the sampling rate can make the identification precision higher without changing the calculation speed. It can provide the theoretical basis for the IF identification of a grid-connected inverter and other automatic devices in the power system.