Uditha L. Jayarathne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Uditha L. Jayarathne has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Elvis C. S. Chen
Department of Medical Biophysics, Robarts Research Institute, Western University, London, ON, Canada
4 shared publications - Terry M. Peters
Robarts Research Institute, Western University, London, Canada
3 shared publications Terry M. Peters
Robarts Research Institute
2 shared publications- Xiongbiao Luo
Western University
2 shared publications A. Jonathan McLeod
Western University, London, Ontario, Canada
1 shared publication- Adam Rankin
Robarts Research Institute, Western University, London, ON, Canada
1 shared publication
Latest Publications
- 4 September 2017
- Published by Springer Nature
- p. 602-609
Real-Time 3D Ultrasound Reconstruction and Visualization in the Context of Laparoscopy
- 4 September 2017
- Published by Springer Nature
- p. 602-609
Real-Time 3D Ultrasound Reconstruction and Visualization in the Context of Laparoscopy
- 19 April 2017
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (7) , 1141-1149
Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution
Purpose Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate “hand-eye” calibration to determine the geometrical relationship between the surgical camera and tracking markers. Methods Using a tracked ball-tip stylus, we formulated hand-eye calibration as a Perspective-n-Point problem, which can be solved efficiently and accurately using as few as 15 measurements. Results The proposed hand-eye calibration algorithm was applied to three types of camera and validated against five other widely used methods. Using projection error as the accuracy metric, our proposed algorithm compared favourably with existing methods. Conclusion We present a fully automated hand-eye calibration technique, based on Procrustean point-to-line registration, which provides superior results for calibrating surgical cameras when compared to existing methods.
- 19 April 2017
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (7) , 1141-1149
Hand-eye calibration for surgical cameras: a Procrustean Perspective-n-Point solution
Purpose Surgical cameras are prevalent in modern operating theatres often used as surrogates for direct vision. A surgical navigational system is a useful adjunct, but requires an accurate “hand-eye” calibration to determine the geometrical relationship between the surgical camera and tracking markers. Methods Using a tracked ball-tip stylus, we formulated hand-eye calibration as a Perspective-n-Point problem, which can be solved efficiently and accurately using as few as 15 measurements. Results The proposed hand-eye calibration algorithm was applied to three types of camera and validated against five other widely used methods. Using projection error as the accuracy metric, our proposed algorithm compared favourably with existing methods. Conclusion We present a fully automated hand-eye calibration technique, based on Procrustean point-to-line registration, which provides superior results for calibrating surgical cameras when compared to existing methods.
- 10 December 2015
- Published by Springer Nature
- p. 134-144
Simultaneous Estimation of Feature Correspondence and Stereo Object Pose with Application to Ultrasound Augmented Robotic Laparoscopy
- 10 December 2015
- Published by Springer Nature
- p. 134-144
Simultaneous Estimation of Feature Correspondence and Stereo Object Pose with Application to Ultrasound Augmented Robotic Laparoscopy
- 4 August 2015
- Published by Springer Nature
- p. 664-676
Binocular Endoscopic 3-D Scene Reconstruction Using Color and Gradient-Boosted Aggregation Stereo Matching for Robotic Surgery
- 4 August 2015
- Published by Springer Nature
- p. 664-676
Binocular Endoscopic 3-D Scene Reconstruction Using Color and Gradient-Boosted Aggregation Stereo Matching for Robotic Surgery
- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 16, 363-370
Robust Intraoperative US Probe Tracking Using a Monocular Endoscopic Camera
In the context of minimally-invasive procedures involving both endoscopic video and ultrasound, we present a vision-based method to track the ultrasound probe using a standard monocular video laparoscopic instrument. This approach requires only cosmetic modification to the ultrasound probe and obviates the need for magnetic tracking of either instrument. We describe an Extended Kalman Filter framework that solves for both the feature correspondence and pose estimation, and is able to track a 3D pattern on the surface of the ultrasound probe in near real-time. The tracking capability is demonstrated by performing an ultrasound calibration of a visually-tracked ultrasound probe, using a standard endoscopic video camera. Ultrasound calibration resulted in a mean TRE of 2.3mm, and comparison with an external optical tracker demonstrated a mean FRE of 4.4mm between the two tracking systems.
- 1 January 2013
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 16, 363-370
Robust Intraoperative US Probe Tracking Using a Monocular Endoscopic Camera
In the context of minimally-invasive procedures involving both endoscopic video and ultrasound, we present a vision-based method to track the ultrasound probe using a standard monocular video laparoscopic instrument. This approach requires only cosmetic modification to the ultrasound probe and obviates the need for magnetic tracking of either instrument. We describe an Extended Kalman Filter framework that solves for both the feature correspondence and pose estimation, and is able to track a 3D pattern on the surface of the ultrasound probe in near real-time. The tracking capability is demonstrated by performing an ultrasound calibration of a visually-tracked ultrasound probe, using a standard endoscopic video camera. Ultrasound calibration resulted in a mean TRE of 2.3mm, and comparison with an external optical tracker demonstrated a mean FRE of 4.4mm between the two tracking systems.