Rongchao Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rongchao Pan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Christof Schulz
University of Duisburg-Essen
4 shared publications T. Dreier
Institute for Combustion and Gas Dynamics–Reactive Fluids, University of Duisburg-Essen, Carl-Benz-Str. 199, 47057 Duisburg, Germany
4 shared publicationsJ. B. Jeffries
Institute for Combustion and Gas Dynamics – Reactive Fluids, University of Duisburg-Essen, Duisburg, Germany
3 shared publicationsC. Brocksieper
Institute for Combustion and Gas Dynamics – Reactive Fluids, University of Duisburg-Essen, Duisburg, Germany
1 shared publication- Franz J. T. Huber
Lehrstuhl für Technische Thermodynamik (LTT), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Am Weichselgarten 8, 91058 Erlangen, Germany
1 shared publication K. J. Daun
Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave West, Waterloo, Ontario N2L 3G1, Canada
1 shared publication
Latest Publications
- Open Access
- 28 June 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (14) , 18105-18114
Burst-mode OH/CH2O planar laser-induced fluorescence imaging of the heat release zone in an unsteady flame
The paper presents simultaneous high-speed (7.5 kHz) planar laser-induced fluorescence (PLIF) of formaldehyde (CH2O) and the hydroxyl-radical (OH) for visualization of the flame structure and heat release zone in a non-premixed unsteady CH4/O2/N2 flame. For this purpose, a dye laser designed for high-speed operation is pumped by the second-harmonic 532 nm output of a Nd:YAG burst-mode laser to produce a tunable, 566 nm beam. After frequency doubling a high-energy kHz-rate narrowband pulse train of approximately 2.2 mJ/pulse at 283 nm is used for excitation of the OH radical. Simultaneously, CH2O is excited by the frequency-tripled output of the same Nd:YAG laser, providing a high-frequency pulse train over 10 ms in duration at high pulse energies (>100 mJ/pulse). The excitation energies enable signal-to-noise ratios (SNRs) of ~10 and ~60 for CH2O and OH PLIF, respectively, using a single high-speed intensified CMOS camera equipped with an image doubler. This allows sufficient SNR for investigation of the temporal evolution of the primary heat release zone and the local flame structure at kHz rates from the spatial overlap of the OH- and CH2O-PLIF signals.
- 28 June 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (14) , 18105-18114
Open AccessBurst-mode OH/CH2O planar laser-induced fluorescence imaging of the heat release zone in an unsteady flame
The paper presents simultaneous high-speed (7.5 kHz) planar laser-induced fluorescence (PLIF) of formaldehyde (CH2O) and the hydroxyl-radical (OH) for visualization of the flame structure and heat release zone in a non-premixed unsteady CH4/O2/N2 flame. For this purpose, a dye laser designed for high-speed operation is pumped by the second-harmonic 532 nm output of a Nd:YAG burst-mode laser to produce a tunable, 566 nm beam. After frequency doubling a high-energy kHz-rate narrowband pulse train of approximately 2.2 mJ/pulse at 283 nm is used for excitation of the OH radical. Simultaneously, CH2O is excited by the frequency-tripled output of the same Nd:YAG laser, providing a high-frequency pulse train over 10 ms in duration at high pulse energies (>100 mJ/pulse). The excitation energies enable signal-to-noise ratios (SNRs) of ~10 and ~60 for CH2O and OH PLIF, respectively, using a single high-speed intensified CMOS camera equipped with an image doubler. This allows sufficient SNR for investigation of the temporal evolution of the primary heat release zone and the local flame structure at kHz rates from the spatial overlap of the OH- and CH2O-PLIF signals.
- 18 January 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (11) , E1-E7
Uncertainty quantification and design-of-experiment in absorption-based aqueous film parameter measurements using Bayesian inference
Diode laser-based multi-wavelength near-infrared (NIR) absorption in aqueous films is a promising diagnostic for making temporally resolved, simultaneous measurements of film thickness, temperature, and concentration of a solute. Our previous work in aqueous urea solutions aimed at determining simultaneously two of these system parameters, while the third one must be fixed or specified by additional measurements. The current work presents a simultaneous NIR absorption-based multi-parameter measurement of thickness, temperature, and solute concentration coupled with the Bayesian methodology that is used to infer probability densities for the obtained data. The Bayesian analysis is based on a temperature- and concentration-dependent spectral database generated with a Fourier transform infrared spectrometer in the range for water with variable temperature and urea concentration. The concept was first validated with measurements using a calibration cell. Probability densities in the measured parameters were quantified using a Markov chain Monte Carlo algorithm, which were used to derive credibility intervals. As a practical demonstration, the temporal variation of film thickness, urea concentration, and liquid temperature were recorded during evaporation of a liquid film deposited on a transparent heated quartz plate.- 18 January 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (11) , E1-E7
Uncertainty quantification and design-of-experiment in absorption-based aqueous film parameter measurements using Bayesian inference
Diode laser-based multi-wavelength near-infrared (NIR) absorption in aqueous films is a promising diagnostic for making temporally resolved, simultaneous measurements of film thickness, temperature, and concentration of a solute. Our previous work in aqueous urea solutions aimed at determining simultaneously two of these system parameters, while the third one must be fixed or specified by additional measurements. The current work presents a simultaneous NIR absorption-based multi-parameter measurement of thickness, temperature, and solute concentration coupled with the Bayesian methodology that is used to infer probability densities for the obtained data. The Bayesian analysis is based on a temperature- and concentration-dependent spectral database generated with a Fourier transform infrared spectrometer in the range for water with variable temperature and urea concentration. The concept was first validated with measurements using a calibration cell. Probability densities in the measured parameters were quantified using a Markov chain Monte Carlo algorithm, which were used to derive credibility intervals. As a practical demonstration, the temporal variation of film thickness, urea concentration, and liquid temperature were recorded during evaporation of a liquid film deposited on a transparent heated quartz plate.- 13 September 2016
- Published by Springer Nature in Applied Physics B
- Vol. 122 (9) , 1-7
Diode laser-based standoff absorption measurement of water film thickness in retro-reflection
- 13 September 2016
- Published by Springer Nature in Applied Physics B
- Vol. 122 (9) , 1-7
Diode laser-based standoff absorption measurement of water film thickness in retro-reflection
- 19 January 2016
- Published by Springer Nature in Applied Physics B
- Vol. 122 (1) , 1-10
Measurements of liquid film thickness, concentration, and temperature of aqueous urea solution by NIR absorption spectroscopy
- 19 January 2016
- Published by Springer Nature in Applied Physics B
- Vol. 122 (1) , 1-10
Measurements of liquid film thickness, concentration, and temperature of aqueous urea solution by NIR absorption spectroscopy
- 7 June 2015
- Published by Springer Nature in Applied Physics B
- Vol. 120 (3) , 397-406
Measurements of liquid film thickness, concentration and temperature of aqueous NaCl solution by NIR absorption spectroscopy
- 7 June 2015
- Published by Springer Nature in Applied Physics B
- Vol. 120 (3) , 397-406
Measurements of liquid film thickness, concentration and temperature of aqueous NaCl solution by NIR absorption spectroscopy