Gabriela Diaconu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gabriela Diaconu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- David Anderson
Joint Research Centre, European Commission, Geel, Belgium
2 shared publications - Grzegorz Rarata
Joint Research Centre, European Commission, Retieseweg 111, 2440 Geel, Belgium
2 shared publications - Dimitris Kyprianou
Joint Research Centre, European Commission, Retieseweg 111, 2440 Geel, Belgium
1 shared publication - Giovanni Emma
Joint Research Centre, European Commission, Retieseweg 111, 2440 Geel, Belgium
1 shared publication - Michael Berglund
Joint Research Centre, European Commission, Retieseweg 111, 2440 Geel, Belgium
1 shared publication - Miguel Ruiz Oses
Stony Brook Univ. (United States)
1 shared publication
Latest Publications
- Open Access
Synthesis of 2,4,6-Trinitrotoluene (TNT) Using Flow Chemistry
This paper describes the nitration of 2,4-dinitrotoluene (DNT) and its conversion to 2,4,6-trinitrotoluene (TNT) at a gram scale with the use of a fully automated flow chemistry system. The conversion of DNT to TNT traditionally requires the use of highly hazardous reagents like fuming sulfuric acid (oleum), fuming nitric acid (90–100%), and elevated temperatures. Flow chemistry offers advantages compared to conventional syntheses including a high degree of safety and simpler multistep automation. The configuration and development of this automated process based on a commercially available flow chemistry system is described. A high conversion rate (>99%) was achieved. Unlike established synthetic methods, ordinary nitrating mixture (65% HNO3/98% H2SO4) and shorter reaction times (10–30 min) were applied. The viability of flow nitration as a means of safe and continuous synthesis of TNT was investigated. The method was optimized using an experimental design approach, and the resulting process is safer, faster, and more efficient than previously reported TNT synthesis procedures. We compared the flow chemistry and batch approaches, including a provisional cost calculation for laboratory-scale production (a thorough economic analysis is, however, beyond the scope of this article). The method is considered fit for purpose for the safe production of high-purity explosives standards at a gram scale, which are used to verify that the performance of explosive trace detection equipment complies with EU regulatory requirements.
Open AccessSynthesis of 2,4,6-Trinitrotoluene (TNT) Using Flow Chemistry
This paper describes the nitration of 2,4-dinitrotoluene (DNT) and its conversion to 2,4,6-trinitrotoluene (TNT) at a gram scale with the use of a fully automated flow chemistry system. The conversion of DNT to TNT traditionally requires the use of highly hazardous reagents like fuming sulfuric acid (oleum), fuming nitric acid (90–100%), and elevated temperatures. Flow chemistry offers advantages compared to conventional syntheses including a high degree of safety and simpler multistep automation. The configuration and development of this automated process based on a commercially available flow chemistry system is described. A high conversion rate (>99%) was achieved. Unlike established synthetic methods, ordinary nitrating mixture (65% HNO3/98% H2SO4) and shorter reaction times (10–30 min) were applied. The viability of flow nitration as a means of safe and continuous synthesis of TNT was investigated. The method was optimized using an experimental design approach, and the resulting process is safer, faster, and more efficient than previously reported TNT synthesis procedures. We compared the flow chemistry and batch approaches, including a provisional cost calculation for laboratory-scale production (a thorough economic analysis is, however, beyond the scope of this article). The method is considered fit for purpose for the safe production of high-purity explosives standards at a gram scale, which are used to verify that the performance of explosive trace detection equipment complies with EU regulatory requirements.
- Open Access
Development of Inert, Polymer-Bonded Simulants for Explosives Detection Systems Based on Transmission X-ray
Explosives detection systems (EDS) based on X-ray are used at airports to screen baggage for the presence of explosives. In Europe and the United States, EDS equipment is tested extensively by specialist test centres prior to approval for operational use in airports. Once EDS are installed in airports, however, it can be challenging to test the EDS equipment and verify that it continues to perform at the highest level, because of the impracticality of introducing bulk explosives into civil aviation airports. We have developed inert, non-toxic polymer-bonded simulants and validated them against real explosives using EDS equipment. The accuracy of our simulants is within 1% of the target bulk density, and within 2% of the target effective atomic number, and the materials have a stability of at least 4 years, with an uncertainty of 0.5%. The simulants generate alarms in almost 100% of cases on a wide range of commercial EDS models, and we consider the simulants fit for purpose for use during testing of EDS equipment at airports.
Open AccessDevelopment of Inert, Polymer-Bonded Simulants for Explosives Detection Systems Based on Transmission X-ray
Explosives detection systems (EDS) based on X-ray are used at airports to screen baggage for the presence of explosives. In Europe and the United States, EDS equipment is tested extensively by specialist test centres prior to approval for operational use in airports. Once EDS are installed in airports, however, it can be challenging to test the EDS equipment and verify that it continues to perform at the highest level, because of the impracticality of introducing bulk explosives into civil aviation airports. We have developed inert, non-toxic polymer-bonded simulants and validated them against real explosives using EDS equipment. The accuracy of our simulants is within 1% of the target bulk density, and within 2% of the target effective atomic number, and the materials have a stability of at least 4 years, with an uncertainty of 0.5%. The simulants generate alarms in almost 100% of cases on a wide range of commercial EDS models, and we consider the simulants fit for purpose for use during testing of EDS equipment at airports.