Mingjing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mingjing Chen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Guanzheng Liu
School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, China
4 shared publications - Keming Wei
School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, China
2 shared publications - Qian Wang
School of Biomedical Engineering, Guangzhou Medical University, Guangzhou 511436, P. R. China
2 shared publications - Aodi He
School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China
1 shared publication - Changhong Wang
School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, Guangdong, China
1 shared publication - Jingtao Zhang
School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University
1 shared publication
Latest Publications
- Open Access
- 6 January 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13, e75465
Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study
Background: Entrapment of sickled red blood cells in the microvasculature leads to sudden painful vaso-occlusive crises (VOCs) in sickle cell disease (SCD). This is potentially triggered by autonomic nervous system–mediated vasoconstriction in the microvasculature. Indeed, vasoconstriction biomarkers derived from a single night of laboratory-based fingertip photoplethysmography (PPG) recording were predictive of a higher frequency of future VOC in SCD. Noninvasive, remote, and longitudinal monitoring of autonomic vasoreactivity will facilitate the development of predictive biomarkers of imminent VOC. Objective: This study aimed to assess the feasibility and performance of a wearable wristband device to longitudinally monitor nocturnal peripheral autonomic vasoreactivity and to cross-validate the vasoconstriction parameters across the “gold-standard” finger sensor. Methods: A total of 12 patients with SCD and 6 healthy controls were recruited to wear a wristband device (Biostrap) with a PPG sensor on a nightly basis. For cross-validation studies, 50% (3/6) controls wore both the wristband and a sleep monitoring device (AliceNightOne) with a finger PPG sensor. We quantified autonomic vasoreactivity by processing PPG signals and deriving vasoconstriction parameters—magnitude of vasoconstriction (Mvasoc) and photoplethysmography amplitude coefficient of variation (PPGampCV). We performed a correlation analysis of the vasoconstriction parameters within each device to investigate whether Mvasoc and PPGampCV can be used as surrogate markers of vasoconstriction, and then cross-validated the PPGampCV across the wristband and finger PPG devices. Results: A total of 131 nocturnal PPG recordings were made with a wristband device (1‐19 nights per participant; patients with SCD: n=79, 60%; controls: n=52, 40%). A total of 9 nocturnal recordings (3 nights per participant) were made with both wristband and finger sensor devices. Longitudinal continuous PPG recordings were feasible with the wearable device, with significant within-night and night-to-night variability in vasoconstriction parameters, suggesting dynamic changes in autonomic vasoreactivity. Mvasoc and PPGampCV significantly correlated within devices—the maximum overnight correlation was 0.82 ( P <.001) for the finger sensor and 0.69 ( P <.001) for the wristband sensor, suggesting that PPGampCV can serve as a surrogate for Mvasoc. Cross-validation analysis of PPGampCV across wristband and fingertip sensors showed statistically significant correlations on all 9 nights (overnight correlation coefficient ranging from 0.24‐0.7), with some nightly segments of PPGampCV showing very strong correlation across devices. Conclusions: Wearable wristband devices are feasible tools for the collection of continuous PPG measurements and vasoconstriction parameters, which serve as objective markers of autonomic vasoreactivity in users with and without SCD. We have optimized the methods of quantifying vasoconstriction from wearable device PPG signals, and cross-validated them with standardized sensors. These findings enable large-scale, real-time monitoring of autonomic vasoreactivity along with pain outcomes for the development of vasoconstriction parameters as biomarkers imminent VOC in patients with SCD. This biomarker also has the potential to impact other diseases involving autonomic vascular dysregulation.
- 6 January 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13, e75465
Open AccessWearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study
Background: Entrapment of sickled red blood cells in the microvasculature leads to sudden painful vaso-occlusive crises (VOCs) in sickle cell disease (SCD). This is potentially triggered by autonomic nervous system–mediated vasoconstriction in the microvasculature. Indeed, vasoconstriction biomarkers derived from a single night of laboratory-based fingertip photoplethysmography (PPG) recording were predictive of a higher frequency of future VOC in SCD. Noninvasive, remote, and longitudinal monitoring of autonomic vasoreactivity will facilitate the development of predictive biomarkers of imminent VOC. Objective: This study aimed to assess the feasibility and performance of a wearable wristband device to longitudinally monitor nocturnal peripheral autonomic vasoreactivity and to cross-validate the vasoconstriction parameters across the “gold-standard” finger sensor. Methods: A total of 12 patients with SCD and 6 healthy controls were recruited to wear a wristband device (Biostrap) with a PPG sensor on a nightly basis. For cross-validation studies, 50% (3/6) controls wore both the wristband and a sleep monitoring device (AliceNightOne) with a finger PPG sensor. We quantified autonomic vasoreactivity by processing PPG signals and deriving vasoconstriction parameters—magnitude of vasoconstriction (Mvasoc) and photoplethysmography amplitude coefficient of variation (PPGampCV). We performed a correlation analysis of the vasoconstriction parameters within each device to investigate whether Mvasoc and PPGampCV can be used as surrogate markers of vasoconstriction, and then cross-validated the PPGampCV across the wristband and finger PPG devices. Results: A total of 131 nocturnal PPG recordings were made with a wristband device (1‐19 nights per participant; patients with SCD: n=79, 60%; controls: n=52, 40%). A total of 9 nocturnal recordings (3 nights per participant) were made with both wristband and finger sensor devices. Longitudinal continuous PPG recordings were feasible with the wearable device, with significant within-night and night-to-night variability in vasoconstriction parameters, suggesting dynamic changes in autonomic vasoreactivity. Mvasoc and PPGampCV significantly correlated within devices—the maximum overnight correlation was 0.82 ( P <.001) for the finger sensor and 0.69 ( P <.001) for the wristband sensor, suggesting that PPGampCV can serve as a surrogate for Mvasoc. Cross-validation analysis of PPGampCV across wristband and fingertip sensors showed statistically significant correlations on all 9 nights (overnight correlation coefficient ranging from 0.24‐0.7), with some nightly segments of PPGampCV showing very strong correlation across devices. Conclusions: Wearable wristband devices are feasible tools for the collection of continuous PPG measurements and vasoconstriction parameters, which serve as objective markers of autonomic vasoreactivity in users with and without SCD. We have optimized the methods of quantifying vasoconstriction from wearable device PPG signals, and cross-validated them with standardized sensors. These findings enable large-scale, real-time monitoring of autonomic vasoreactivity along with pain outcomes for the development of vasoconstriction parameters as biomarkers imminent VOC in patients with SCD. This biomarker also has the potential to impact other diseases involving autonomic vascular dysregulation.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Graph-Weighted High-Dimensional Information-Based Similarity for Detecting Altered Brain Functional Connectivity in Sleep Apnea Patients
Sleep apnea (SA) is a common respiratory disease associated with changes in the cortical connectivity pattern of the brain, leading to a growing social and medical burden. The electroencephalogram (EEG)-based analysis can help to understand the pathological mechanism of SA in the brain. Information-based similarity (IBS) is an effective method for measuring the nonlinear similarity of two physiological signals and has the potential for SA screening. However, the traditional IBS method can only extract local information, failing to fully capture pathological EEG patterns characterized by critical cross-frequency dynamics and regional variability. To address these issues, we propose graph-weighted high-dimensional information-based similarity (HGIBS), which integrates 2-D IBS into global information, thus improving the accuracy and reliability of SA detection. We use EEG energy sequences from multiple brain regions and frequency bands, divide their wave patterns into several modes, and calculate their similarity by comparing the distribution of the appearance frequency of the modes. Additionally, we construct the brain network graph and extend the calculation of similarity to high-dimensional space, thereby integrating local information into global information. We evaluated the performance of the HGIBS method on dataset of 88 participants and achieved a correlation between HGIBS and apnea-hypopnea index (AHI) of 0.730, with an accuracy of 89.4% in severe SA classification, demonstrating the superiority. This method has the potential to become a new SA screening indicator and provide a deeper understanding of the pathological mechanism of SA research.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Graph-Weighted High-Dimensional Information-Based Similarity for Detecting Altered Brain Functional Connectivity in Sleep Apnea Patients
Sleep apnea (SA) is a common respiratory disease associated with changes in the cortical connectivity pattern of the brain, leading to a growing social and medical burden. The electroencephalogram (EEG)-based analysis can help to understand the pathological mechanism of SA in the brain. Information-based similarity (IBS) is an effective method for measuring the nonlinear similarity of two physiological signals and has the potential for SA screening. However, the traditional IBS method can only extract local information, failing to fully capture pathological EEG patterns characterized by critical cross-frequency dynamics and regional variability. To address these issues, we propose graph-weighted high-dimensional information-based similarity (HGIBS), which integrates 2-D IBS into global information, thus improving the accuracy and reliability of SA detection. We use EEG energy sequences from multiple brain regions and frequency bands, divide their wave patterns into several modes, and calculate their similarity by comparing the distribution of the appearance frequency of the modes. Additionally, we construct the brain network graph and extend the calculation of similarity to high-dimensional space, thereby integrating local information into global information. We evaluated the performance of the HGIBS method on dataset of 88 participants and achieved a correlation between HGIBS and apnea-hypopnea index (AHI) of 0.730, with an accuracy of 89.4% in severe SA classification, demonstrating the superiority. This method has the potential to become a new SA screening indicator and provide a deeper understanding of the pathological mechanism of SA research.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 737-748
A Novel Heart Rate Variability Measurement Method for Detecting Obstructive Sleep Apnea Using Local Difference Visibility Graphs
Obstructive sleep apnea (OSA) is a common and chronic respiratory disorder. Autonomic dysfunction and heart rate change usually occur during apneic events. Damaged autonomic nerve system modulation can lead to morphological differences in R-to-R intervals (RRI) series. Capable of capturing structural properties of RRI series and thus assessing the heart rate dynamics, the local difference visibility graphs (LDVG) method was proposed as a novel OSA detection method in this study. The LDVG method focuses on long continuous ascent range, which is likely to be induced by OSA attack, demonstrating the characteristics of bradycardia and tachycardia in OSA. Combined with the local strategy, it avoids heavy workload while maintaining major correlations. Degree mean of LDVG (LDVG_M) and degree uncertainty of LDVG (LDVG_SEn) were calculated as the mean and Shannon entropy of the degree sequence of LDVG, which can quantify the tightness and uncertainty of structural characteristics of the RR interval series, respectively. 60 ECG recordings from the Physionet database were used in this study. Both LDVG_M and LDVG_SEn achieved a good performance in differentiating the severity of diseases, while the classic index low-frequency power to high-frequency power ratio value (LF/HF) cannot. Then, binary classification was performed. In OSA detection, the accuracy, specificity, sensitivity of both LDVG-related indices were all above 90%. LDVG_SEn achieved the highest accuracy (96.7%), while maintaining a good balance between sensitivity (97.5%) and specificity (95.0%). Therefore, this LDVG method provides an insight into the underlying pathological mechanism of OSA and is promising for clinical and home monitoring.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 737-748
A Novel Heart Rate Variability Measurement Method for Detecting Obstructive Sleep Apnea Using Local Difference Visibility Graphs
Obstructive sleep apnea (OSA) is a common and chronic respiratory disorder. Autonomic dysfunction and heart rate change usually occur during apneic events. Damaged autonomic nerve system modulation can lead to morphological differences in R-to-R intervals (RRI) series. Capable of capturing structural properties of RRI series and thus assessing the heart rate dynamics, the local difference visibility graphs (LDVG) method was proposed as a novel OSA detection method in this study. The LDVG method focuses on long continuous ascent range, which is likely to be induced by OSA attack, demonstrating the characteristics of bradycardia and tachycardia in OSA. Combined with the local strategy, it avoids heavy workload while maintaining major correlations. Degree mean of LDVG (LDVG_M) and degree uncertainty of LDVG (LDVG_SEn) were calculated as the mean and Shannon entropy of the degree sequence of LDVG, which can quantify the tightness and uncertainty of structural characteristics of the RR interval series, respectively. 60 ECG recordings from the Physionet database were used in this study. Both LDVG_M and LDVG_SEn achieved a good performance in differentiating the severity of diseases, while the classic index low-frequency power to high-frequency power ratio value (LF/HF) cannot. Then, binary classification was performed. In OSA detection, the accuracy, specificity, sensitivity of both LDVG-related indices were all above 90%. LDVG_SEn achieved the highest accuracy (96.7%), while maintaining a good balance between sensitivity (97.5%) and specificity (95.0%). Therefore, this LDVG method provides an insight into the underlying pathological mechanism of OSA and is promising for clinical and home monitoring.
- 1 November 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 211, 106442
Sleep apnea screening based on Photoplethysmography data from wearable bracelets using an information-based similarity approach
- 1 November 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 211, 106442
Sleep apnea screening based on Photoplethysmography data from wearable bracelets using an information-based similarity approach
- Open Access
Empirical Mode Decomposition as a Novel Approach to Study Heart Rate Variability in Congestive Heart Failure Assessment
Congestive heart failure (CHF) is a cardiovascular disease related to autonomic nervous system (ANS) dysfunction and fragmented patterns. There is a growing demand for assessing CHF accurately. In this work, 24-h RR interval signals (the time elapsed between two successive R waves of the QRS signal on the electrocardiogram) of 98 subjects (54 healthy and 44 CHF subjects) were analyzed. Empirical mode decomposition (EMD) was chosen to decompose RR interval signals into four intrinsic mode functions (IMFs). Then transfer entropy (TE) was employed to study the information transaction among four IMFs. Compared with the normal group, significant decrease in TE (*→1; information transferring from other IMFs to IMF1, p < 0.001) and TE (3→*; information transferring from IMF3 to other IMFs, p < 0.05) was observed. Moreover, the combination of TE (*→1), TE (3→*) and LF/HF reached the highest CHF screening accuracy (85.7%) in IBM SPSS Statistics discriminant analysis, while LF/HF only achieved 79.6%. This novel method and indices could serve as a new way to assessing CHF and studying the interaction of the physiological phenomena. Simulation examples and transfer entropy applications are provided to demonstrate the effectiveness of the proposed EMD decomposition method in assessing CHF.
Open AccessEmpirical Mode Decomposition as a Novel Approach to Study Heart Rate Variability in Congestive Heart Failure Assessment
Congestive heart failure (CHF) is a cardiovascular disease related to autonomic nervous system (ANS) dysfunction and fragmented patterns. There is a growing demand for assessing CHF accurately. In this work, 24-h RR interval signals (the time elapsed between two successive R waves of the QRS signal on the electrocardiogram) of 98 subjects (54 healthy and 44 CHF subjects) were analyzed. Empirical mode decomposition (EMD) was chosen to decompose RR interval signals into four intrinsic mode functions (IMFs). Then transfer entropy (TE) was employed to study the information transaction among four IMFs. Compared with the normal group, significant decrease in TE (*→1; information transferring from other IMFs to IMF1, p < 0.001) and TE (3→*; information transferring from IMF3 to other IMFs, p < 0.05) was observed. Moreover, the combination of TE (*→1), TE (3→*) and LF/HF reached the highest CHF screening accuracy (85.7%) in IBM SPSS Statistics discriminant analysis, while LF/HF only achieved 79.6%. This novel method and indices could serve as a new way to assessing CHF and studying the interaction of the physiological phenomena. Simulation examples and transfer entropy applications are provided to demonstrate the effectiveness of the proposed EMD decomposition method in assessing CHF.