Qian Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qian Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Guanzheng Liu
School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, China
2 shared publications - Mingjing Chen
Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States
2 shared publications - Aodi He
School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510275, China
1 shared publication - Biyuan Lin
School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
1 shared publication - Boyuan Cheng
School of Automation, Northwestern Polytechnical University, Xian, China
1 shared publication Changhong Wang
Shenzhen Campus of Sun Yat-sen University
1 shared publication
Latest Publications
- Open Access
- 3 June 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
In vivo assessment of the testosterone-induced PCOS process on adult zebrafish model with spectral-domain optical coherence tomography
Polycystic ovary syndrome (PCOS) is a common endocrine disorder characterized by ovarian dysfunction and hyperandrogenism. Research into its dynamic pathological mechanisms is limited by the invasive nature of conventional histological methods, which preclude monitoring in live models. The zebrafish has emerged as a valuable model for PCOS due to its physiological similarities to humans. This study explores the application of spectral-domain optical coherence tomography (SD-OCT) as a high-resolution imaging tool for the assessment of PCOS progression and treatment in zebrafish. A testosterone-induced PCOS model was established in adult female zebrafish. The therapeutic efficacy of two doses of Metformin was evaluated. The core methodology involved in vivo SD-OCT imaging of ovarian follicles at multiple time points over 72[ ]h. These morphological changes observed via SD-OCT were consistently corroborated by histology. Metformin treatment, particularly at the high dose (100[ ]mg/L), demonstrated a pronounced therapeutic effect, effectively reversing the testosterone-induced follicular arrest and normalizing ovarian testosterone levels and gonadosomatic index (GSI). This study validates SD-OCT as a powerful and reliable modality for non-invasive monitoring of PCOS in a live zebrafish model.
- 3 June 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
Open AccessIn vivo assessment of the testosterone-induced PCOS process on adult zebrafish model with spectral-domain optical coherence tomography
Polycystic ovary syndrome (PCOS) is a common endocrine disorder characterized by ovarian dysfunction and hyperandrogenism. Research into its dynamic pathological mechanisms is limited by the invasive nature of conventional histological methods, which preclude monitoring in live models. The zebrafish has emerged as a valuable model for PCOS due to its physiological similarities to humans. This study explores the application of spectral-domain optical coherence tomography (SD-OCT) as a high-resolution imaging tool for the assessment of PCOS progression and treatment in zebrafish. A testosterone-induced PCOS model was established in adult female zebrafish. The therapeutic efficacy of two doses of Metformin was evaluated. The core methodology involved in vivo SD-OCT imaging of ovarian follicles at multiple time points over 72[ ]h. These morphological changes observed via SD-OCT were consistently corroborated by histology. Metformin treatment, particularly at the high dose (100[ ]mg/L), demonstrated a pronounced therapeutic effect, effectively reversing the testosterone-induced follicular arrest and normalizing ovarian testosterone levels and gonadosomatic index (GSI). This study validates SD-OCT as a powerful and reliable modality for non-invasive monitoring of PCOS in a live zebrafish model.
- Open Access
- 18 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 230-236
Heuristics for Digital Educators: Transforming Teaching Method with ECP-Pyramid Model in Eng-medicine Inter-disciplines
- 18 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 230-236
Open AccessHeuristics for Digital Educators: Transforming Teaching Method with ECP-Pyramid Model in Eng-medicine Inter-disciplines
- Open Access
- 7 April 2025
- Published by Springer Nature in Research Square
A Non-invasive Blood Glucose Detection Method: Using Fluctuation Analysis to Evaluate Heart Rate Variability
Blood glucose (BG) detection is of great importance for diabetes prevention in healthy individuals. However, the traditional invasive detection methods have disadvantages, such as causing pain and inconvenience. Additionally, BG changes can disrupt the balance of the autonomic nervous system, which can be evaluated using heart rate variability (HRV). For these reasons, this study aims to develop a non-invasive BG level detection method based on HRV. This study proposed dynamic and static fluctuation analysis based on detrended fluctuation analysis (DFA) and multifractal detrended fluctuation analysis (MF-DFA). A physiological measuring system was employed to record the electrocardiogram and obtain R-wave interval (RR) time series during 40 oral glucose tolerance tests in 20 healthy individuals, and the corresponding BG concentrations were measured every 10 minutes. Besides, dynamic and static fluctuation analysis were used to extract HRV features from the RR series and compared with the classical frequency-domain method. Additionally, four machine learning models were applied to classify high and low BG levels to evaluate the effect of non-invasive BG detection. The results demonstrated that both dynamic and static features of DFA and MF-DFA could significantly distinguish different BG levels (p < 0.05). The accuracy, specificity, and sensitivity of the light gradient boosting machine were 80.0%, 74.5%, and 87.2%, respectively. Our model also displayed generalization potential on the D1NAMO dataset. The dynamic and static fluctuation analysis could evaluate the change in HRV under different BG levels. This novel method is a promising technique for non-invasive BG detection in healthy individuals.
- 7 April 2025
- Published by Springer Nature in Research Square
Open AccessA Non-invasive Blood Glucose Detection Method: Using Fluctuation Analysis to Evaluate Heart Rate Variability
Blood glucose (BG) detection is of great importance for diabetes prevention in healthy individuals. However, the traditional invasive detection methods have disadvantages, such as causing pain and inconvenience. Additionally, BG changes can disrupt the balance of the autonomic nervous system, which can be evaluated using heart rate variability (HRV). For these reasons, this study aims to develop a non-invasive BG level detection method based on HRV. This study proposed dynamic and static fluctuation analysis based on detrended fluctuation analysis (DFA) and multifractal detrended fluctuation analysis (MF-DFA). A physiological measuring system was employed to record the electrocardiogram and obtain R-wave interval (RR) time series during 40 oral glucose tolerance tests in 20 healthy individuals, and the corresponding BG concentrations were measured every 10 minutes. Besides, dynamic and static fluctuation analysis were used to extract HRV features from the RR series and compared with the classical frequency-domain method. Additionally, four machine learning models were applied to classify high and low BG levels to evaluate the effect of non-invasive BG detection. The results demonstrated that both dynamic and static features of DFA and MF-DFA could significantly distinguish different BG levels (p < 0.05). The accuracy, specificity, and sensitivity of the light gradient boosting machine were 80.0%, 74.5%, and 87.2%, respectively. Our model also displayed generalization potential on the D1NAMO dataset. The dynamic and static fluctuation analysis could evaluate the change in HRV under different BG levels. This novel method is a promising technique for non-invasive BG detection in healthy individuals.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 737-748
A Novel Heart Rate Variability Measurement Method for Detecting Obstructive Sleep Apnea Using Local Difference Visibility Graphs
Obstructive sleep apnea (OSA) is a common and chronic respiratory disorder. Autonomic dysfunction and heart rate change usually occur during apneic events. Damaged autonomic nerve system modulation can lead to morphological differences in R-to-R intervals (RRI) series. Capable of capturing structural properties of RRI series and thus assessing the heart rate dynamics, the local difference visibility graphs (LDVG) method was proposed as a novel OSA detection method in this study. The LDVG method focuses on long continuous ascent range, which is likely to be induced by OSA attack, demonstrating the characteristics of bradycardia and tachycardia in OSA. Combined with the local strategy, it avoids heavy workload while maintaining major correlations. Degree mean of LDVG (LDVG_M) and degree uncertainty of LDVG (LDVG_SEn) were calculated as the mean and Shannon entropy of the degree sequence of LDVG, which can quantify the tightness and uncertainty of structural characteristics of the RR interval series, respectively. 60 ECG recordings from the Physionet database were used in this study. Both LDVG_M and LDVG_SEn achieved a good performance in differentiating the severity of diseases, while the classic index low-frequency power to high-frequency power ratio value (LF/HF) cannot. Then, binary classification was performed. In OSA detection, the accuracy, specificity, sensitivity of both LDVG-related indices were all above 90%. LDVG_SEn achieved the highest accuracy (96.7%), while maintaining a good balance between sensitivity (97.5%) and specificity (95.0%). Therefore, this LDVG method provides an insight into the underlying pathological mechanism of OSA and is promising for clinical and home monitoring.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 737-748
A Novel Heart Rate Variability Measurement Method for Detecting Obstructive Sleep Apnea Using Local Difference Visibility Graphs
Obstructive sleep apnea (OSA) is a common and chronic respiratory disorder. Autonomic dysfunction and heart rate change usually occur during apneic events. Damaged autonomic nerve system modulation can lead to morphological differences in R-to-R intervals (RRI) series. Capable of capturing structural properties of RRI series and thus assessing the heart rate dynamics, the local difference visibility graphs (LDVG) method was proposed as a novel OSA detection method in this study. The LDVG method focuses on long continuous ascent range, which is likely to be induced by OSA attack, demonstrating the characteristics of bradycardia and tachycardia in OSA. Combined with the local strategy, it avoids heavy workload while maintaining major correlations. Degree mean of LDVG (LDVG_M) and degree uncertainty of LDVG (LDVG_SEn) were calculated as the mean and Shannon entropy of the degree sequence of LDVG, which can quantify the tightness and uncertainty of structural characteristics of the RR interval series, respectively. 60 ECG recordings from the Physionet database were used in this study. Both LDVG_M and LDVG_SEn achieved a good performance in differentiating the severity of diseases, while the classic index low-frequency power to high-frequency power ratio value (LF/HF) cannot. Then, binary classification was performed. In OSA detection, the accuracy, specificity, sensitivity of both LDVG-related indices were all above 90%. LDVG_SEn achieved the highest accuracy (96.7%), while maintaining a good balance between sensitivity (97.5%) and specificity (95.0%). Therefore, this LDVG method provides an insight into the underlying pathological mechanism of OSA and is promising for clinical and home monitoring.
- Open Access
- 5 February 2022
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 29 (1) , 30-37
Thermal Elastohydrodynamic Lubrication Analysis of High-Speed and Light-Load Rolling Bearing with Double Rings Rotation
In order to reveal the lubrication performance of the rolling bearing under the condition of double rings s rotation, a novel rolling bearing contact lubrication analysis model for double rings rotation with an improved load distribution is developed...
- 5 February 2022
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 29 (1) , 30-37
Open AccessThermal Elastohydrodynamic Lubrication Analysis of High-Speed and Light-Load Rolling Bearing with Double Rings Rotation
In order to reveal the lubrication performance of the rolling bearing under the condition of double rings s rotation, a novel rolling bearing contact lubrication analysis model for double rings rotation with an improved load distribution is developed...
- 15 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 1438-1442
Fault Diagnosis of Aircraft Power System Based on Long Short-Term Memory Network
The aircraft power system is the source of electrical energy for all onboard electrical equipment, and plays an important and irreplaceable role in the aircraft. Aiming at the problem that traditional aircraft power system fault diagnosis methods often require the establishment of accurate mathematical models and cannot quickly perform fault diagnosis and identification, this paper proposes an aircraft power system fault diagnosis method based on long and short-term memory networks. Taking the typical components of the aircraft power system integrally driving the generator as an example, the fault diagnosis research is carried out. The simulation model is used to collect fault data to make a fault simulation data set. After many parameter tuning experiments, an ideal fault diagnosis model is obtained. Under the existing experimental conditions and data sets, the fault diagnosis accuracy rate reaches 98.57%, which can meet the needs of actual work to a certain extent.
- 15 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 1438-1442
Fault Diagnosis of Aircraft Power System Based on Long Short-Term Memory Network
The aircraft power system is the source of electrical energy for all onboard electrical equipment, and plays an important and irreplaceable role in the aircraft. Aiming at the problem that traditional aircraft power system fault diagnosis methods often require the establishment of accurate mathematical models and cannot quickly perform fault diagnosis and identification, this paper proposes an aircraft power system fault diagnosis method based on long and short-term memory networks. Taking the typical components of the aircraft power system integrally driving the generator as an example, the fault diagnosis research is carried out. The simulation model is used to collect fault data to make a fault simulation data set. After many parameter tuning experiments, an ideal fault diagnosis model is obtained. Under the existing experimental conditions and data sets, the fault diagnosis accuracy rate reaches 98.57%, which can meet the needs of actual work to a certain extent.
- Open Access
Empirical Mode Decomposition as a Novel Approach to Study Heart Rate Variability in Congestive Heart Failure Assessment
Congestive heart failure (CHF) is a cardiovascular disease related to autonomic nervous system (ANS) dysfunction and fragmented patterns. There is a growing demand for assessing CHF accurately. In this work, 24-h RR interval signals (the time elapsed between two successive R waves of the QRS signal on the electrocardiogram) of 98 subjects (54 healthy and 44 CHF subjects) were analyzed. Empirical mode decomposition (EMD) was chosen to decompose RR interval signals into four intrinsic mode functions (IMFs). Then transfer entropy (TE) was employed to study the information transaction among four IMFs. Compared with the normal group, significant decrease in TE (*→1; information transferring from other IMFs to IMF1, p < 0.001) and TE (3→*; information transferring from IMF3 to other IMFs, p < 0.05) was observed. Moreover, the combination of TE (*→1), TE (3→*) and LF/HF reached the highest CHF screening accuracy (85.7%) in IBM SPSS Statistics discriminant analysis, while LF/HF only achieved 79.6%. This novel method and indices could serve as a new way to assessing CHF and studying the interaction of the physiological phenomena. Simulation examples and transfer entropy applications are provided to demonstrate the effectiveness of the proposed EMD decomposition method in assessing CHF.
Open AccessEmpirical Mode Decomposition as a Novel Approach to Study Heart Rate Variability in Congestive Heart Failure Assessment
Congestive heart failure (CHF) is a cardiovascular disease related to autonomic nervous system (ANS) dysfunction and fragmented patterns. There is a growing demand for assessing CHF accurately. In this work, 24-h RR interval signals (the time elapsed between two successive R waves of the QRS signal on the electrocardiogram) of 98 subjects (54 healthy and 44 CHF subjects) were analyzed. Empirical mode decomposition (EMD) was chosen to decompose RR interval signals into four intrinsic mode functions (IMFs). Then transfer entropy (TE) was employed to study the information transaction among four IMFs. Compared with the normal group, significant decrease in TE (*→1; information transferring from other IMFs to IMF1, p < 0.001) and TE (3→*; information transferring from IMF3 to other IMFs, p < 0.05) was observed. Moreover, the combination of TE (*→1), TE (3→*) and LF/HF reached the highest CHF screening accuracy (85.7%) in IBM SPSS Statistics discriminant analysis, while LF/HF only achieved 79.6%. This novel method and indices could serve as a new way to assessing CHF and studying the interaction of the physiological phenomena. Simulation examples and transfer entropy applications are provided to demonstrate the effectiveness of the proposed EMD decomposition method in assessing CHF.