Ran Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ran Guo has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ji Chen
University of Houston
1 shared publication - Jianfeng Zheng
Department of Electrical and Computer Engineering University of Houston Houston Texas USA
1 shared publication - Rui Yang
Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204 USA
1 shared publication - Wolfgang Kainz
High Performance Computing for MRI Safety, Jasper, GA, USA
1 shared publication - Yu Wang
Department of Electrical and Computer Engineering, University of Houston, Houston, TX, USA
1 shared publication
Latest Publications
- 26 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 61 (6) , 1726-1732
An Absorbing Radio Frequency Shield to Reduce RF Heating Induced by Deep Brain Stimulator During 1.5-T MRI
In this paper, an absorbing radio frequency shield (ARFS) is developed to reduce the radio frequency (RF)-induced heating for active implantable medical device (AIMD) during magnetic resonance imaging (MRI). Using the ARFS, the strength of the incident electric field within the shielded region is significantly decreased, and subsequently the induced temperature rises near the tip of AIMD. Both numerical and experimental studies show that the proposed design of ARFS can effectively reduce the temperature rise induced by an AIMD and can mitigate the MRI RF heating risks for patients with AIMDs.
- 26 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 61 (6) , 1726-1732
An Absorbing Radio Frequency Shield to Reduce RF Heating Induced by Deep Brain Stimulator During 1.5-T MRI
In this paper, an absorbing radio frequency shield (ARFS) is developed to reduce the radio frequency (RF)-induced heating for active implantable medical device (AIMD) during magnetic resonance imaging (MRI). Using the ARFS, the strength of the incident electric field within the shielded region is significantly decreased, and subsequently the induced temperature rises near the tip of AIMD. Both numerical and experimental studies show that the proposed design of ARFS can effectively reduce the temperature rise induced by an AIMD and can mitigate the MRI RF heating risks for patients with AIMDs.