  • Lead-Specific Optimization of Transfer Function Validation Pathways for Magnetic Resonance RF Safety Evaluation

    by Zhichao Wang, Ziyu Zuo, Shuo Song, Jianfeng Zheng, Qingyan Wang, Yu Wang, Wolfgang Kainz, Ji Chen

    This article presents a novel lead-specific validation method for magnetic resonance radiofrequency safety evaluations on active implantable medical devices (AIMDs). The proposed method designs a set of optimized validation pathways for the specific AIMD lead which achieve 1) high temperature rise or high induced voltages during the validation measurements with 2) minimally correlated electric fields along the pathways inside a electric field generating phantom box. The novel strategy 1) calculates the heating, or the induced voltage, for 603 preselected pathways and ranks these pathways based on temperature rise or voltage values and 2) performs matrix operations on these pathways to select pathways with minimally correlated tangential electric fields to each other. Two commercially available AIMDs were used to demonstrate the effectiveness of this novel strategy. Consequently, the strategy potentially provides a better transfer function validation for AIMD leads in terms of accuracy and completion.


  • A Cascaded Heterogeneous Equivalent Network for Evaluating RF-Induced Hazards on Active Implantable Medical Devices

    by Jingshen Liu, Yu Wang, Ran Guo, Qingyan Wang, Jianfeng Zheng, Krishna Kurpad, Wolfgang Kainz, Ji Chen

    This article presents a cascaded heterogeneous equivalent network for the evaluation of radiofrequency (RF) induced safety hazards on electrically long active implantable medical devices (AIMDs) exposed to magnetic resonance imaging systems. AIMDs in a highly heterogeneous human body are represented by cascaded transmission line models consisting of segments with different values of effective wavenumbers and characteristic impedances. Two terminations, implantable pulse generator (IPG), and lead-tip are modeled as lumped elements. Methods to extract values for lead-tip impedance, IPG impedance, wavenumber, and characteristic impedance of the AIMDs are proposed and validated through numerical simulations and experimental investigations. Based on these values, one can build up a unique AIMD model along each implanted trajectory inside human body models. The developed models can be used to accurately evaluate the RF-induced voltage and heating for each implantation scenario.


  • Magnetic resonance conditionality of abandoned leads from active implantable medical devices at 1.5 T

    by Yu Wang, Ran Guo, Wei Hu, Jianfeng Zheng, Qingyan Wang, Jay Jiang, Krishna K. N. Kurpad, Norbert Kaula, Stuart Long, Ji Chen, et al.

    Purpose During MR scans, abandoned leads from active implantable medical devices (AIMDs) can experience excessive heating at the lead tip, depending on the type of termination applied to the proximal contacts (proximal end treatment). The influence of different proximal end treatments (ie, [1] freely exposed in the tissue, [2] terminated with metal in contact with the tissue, or [3] capped with plastic, and thereby fully insulated, on the RF-induced lead-tip heating) are studied. A technique to ensure that MR Conditional AIMD leads remain MR Conditional even when abandoned is recommended. Methods Abandoned leads from three MR Conditional AIMDs ([1] a sacral neuromodulation system, [2] a cardiac rhythm management pacemaker system, and [3] a deep brain stimulator system) were investigated in this study. The computational lead models (ie, the transfer functions) for different proximal end treatments were measured and used to assess the in vivo lead-tip heating for four virtual human models (FATS, Duke, Ella, and Billie) and compared with the lead-tip heating of the complete MR Conditional AIMD system. Result The average and maximum lead-tip heating for abandoned leads proximally capped with metal is always lower than that from the complete AIMD system. Abandoned leads proximally insulated could lead to an average in vivo temperature rise up to 3.5 times higher than that from the complete AIMD system. Conclusion For the three investigated AIMDs under 1.5T MR scanning, our results indicate that RF-induced lead-tip heating of abandoned leads strongly depends on the proximal lead termination. A metallic cap applied to the proximal termination of the tested leads could significantly reduce the RF-induced lead-tip heating.


  • A technique for the reduction of RF‐induced heating of active implantable medical devices during MRI

    by Yu Wang, Jianfeng Zheng, Ran Guo, Qingyan Wang, Wolfgang Kainz, Stuart Long, Ji Chen

    Purpose The paper presents a novel method to reduce the RF-induced heating of active implantable medical devices during MRI. Methods With the addition of an energy decoying and dissipating structure, RF energy can be redirected toward the dissipating rings through the decoying conductor. Three lead groups (45 cm-50 cm) and 4 (50 cm-100 cm) were studied in 1.5 Tesla MR systems by simulation and measurement, respectively. In vivo modeling was performed using human models to estimate the RF-induced heating of an active implantable medical device for spinal cord treatment. Result In the simulation study, it was shown that the peak 1g-averaged specific absorption rate near the lead-tips can be reduced by 70% to 80% compared to those from the control leads. In the experimental measurements during a 2-min exposure test in a 1.5 Telsa MR system, the temperature rises dropped from the original 18.3℃, 25.8℃, 8.1℃, and 16.1℃ (control leads 1-4) to 5.4℃, 6.9℃, 1.6℃, and 3.3℃ (leads 1-4 with the energy decoying and dissipation structure). The in vivo calculation results show that the maximum induced temperature rise among all cases can be substantially reduced (up to 80%) when the energy decoying and dissipating structures were used. Conclusion Our studies confirm the effectiveness of the novel technique for a variety of scanning scenarios. The results also indicate that the decoying conductor length, number of rings, and ring area must be carefully chosen and validated.


  • Body‐loop related MRI radiofrequency‐induced heating hazards: Observations, characterizations, and recommendations

    by Xiaolin Yang, Jianfeng Zheng, Yu Wang, Stuart A. Long, Wolfgang Kainz, Ji Chen

    Purpose: To assess RF‐induced heating hazards in 1.5T MR systems caused by body‐loop postures.Methods: Twelve advanced high‐resolution anatomically correct human body models with different body‐loop postures are created based on poseable human adult male models. Numerical simulations are performed to assess the radiofrequency (RF)‐induced heating of these 12 models at 11 landmarks. A customized phantom is developed to validate the numerical simulations and quantitatively analyze factors affecting the RF‐induced heating, eg, the contact area, the loop size, and the loading position. The RF‐induced heating inside three differently posed phantoms is measured.Results: The RF‐induced heating from the body‐loop postures can be up to 11 times higher than that from the original posture. The RF‐induced heating increases with increasing body‐loop size and decreasing contact area. The magnetic flux increases when the body‐loop center and the RF coil isocenter are close to each other, leading to increased RF‐induced heating. An air gap created in the body loop or generating a polarized magnetic field parallel to the body loop can reduce the heating by a factor of three at least. Experimental measurements are provided, validating the correctness of the numerical results.Conclusion: Safe patient posture during MR examinations is recommended with the use of insulation materials to prevent loop formation and consequently avoiding high RF‐induced heating. If body loops cannot be avoided, the body loop should be placed outside the RF transmitting coil. In addition, linear polarization with magnetic fields parallel to the body loop can be used to circumvent high RF‐induced heating.


  • Abstract 1274: CCX559 is a potent orally-administered small molecule PD-L1 inhibitor that induces anti-tumor immunity

    by Chris Li, Marta Vilalta, Linda S. Ertl, Yu Wang, Yibin Zeng, Pingchen Fan, Christopher Lange, Darren McMurtrie, Ju Yang, Rebecca Lui, et al.

    Introduction: Cancer cells can escape tumor-specific T cell responses via engagement of inhibitory immune checkpoints. PD-L1/PD-1 interaction is one of the major checkpoints that limit effector T cell function against cancer cells, and monoclonal antibodies that block this interaction have been approved as therapies in multiple tumor indications. As a next generation therapy, small molecule inhibitors of PD-L1 potentially have advantageous properties compared to approved monoclonal antibodies, such as better penetration into solid tumors, reduced immunogenicity, lack of Fc-mediated side effects, convenience of oral administration, and lower cost of goods. We therefore embarked on an effort to identify and develop an orally available small molecule capable of targeting PD-L1/PD-1 interactions. Methods: Inhibition of the PD-L1/PD-1 interaction was measured using a binding assay, followed by a cell culture system assessing PD-1 inhibition of T cell receptor (TCR) activation. Human T cell responses were assessed in vitro using the mixed lymphocyte reaction (MLR) assay, and a human peripheral blood mononuclear cell (PBMC)-mediated tumor cell killing assay. For in vivo studies CCX559 was dosed orally in a syngeneic tumor model and in a human tumor cell/PBMC co-implantation model in immune deficient mice. Results: Using structural information and focused medicinal chemistry, we identified CCX559 as a potent inhibitor of PD-L1 interaction with PD-1. CCX559 prevented PD-L1/PD-1 inhibition of TCR signaling in a cell-based reporter assay, increased IFNγ secretion in allogeneic MLR assays, and increased tumor cell killing by human PBMCs. We demonstrated that CCX559 potentially employs multiple mechanisms to inhibit PD-L1, which are distinct from those published for human anti-PD-L1 antibodies. In murine tumor models, orally administered CCX559 reduced tumor growth similarly to a clinically-approved anti-human PD-L1 antibody. Summary: CCX559 is a highly potent, small molecule PD-L1 inhibitor that can be orally administered. CCX559 enhanced primary human T cell activity in vitro and demonstrated anti-tumor efficacy in two murine tumor models. Based on its unique mechanism of PD-L1 inhibition, strong anti-tumor activity, desirable drug properties, and good safety profile, we plan to advance CCX559 into clinical development in the first half of 2021. Citation Format: Chris Li, Marta Vilalta, Linda S. Ertl, Yu Wang, Yibin Zeng, Pingchen Fan, Christopher Lange, Darren McMurtrie, Ju Yang, Rebecca Lui, Ryan Scamp, Vicky Chhina, Alice Kumamoto, Ryan Ong, Ton Dang, Ashton Easterday, Niky Zhao, Shirley Liu, Rajinder Singh, Israel Charo, Kathleen Sullivan, Thomas J. Schall, Penglie Zhang. CCX559 is a potent orally-administered small molecule PD-L1 inhibitor that induces anti-tumor immunity [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2021; 2021 Apr 10-15 and May 17-21. Philadelphia (PA): AACR; Cancer Res 2021;81(13_Suppl):Abstract nr 1274.


  • A Fast and Accurate Transfer Function Validation Strategy Using Optimized Rotation-Invariant Lead Trajectories

    by Yu Wang, Jianfeng Zheng, Qingyan Wang, Ji Chen, Wolfgang Kainz

    This article demonstrates a novel strategy to effectively and efficiently validate the lead transfer function model, which is used to predict the radiofrequency induced heating near the distal end of active implantable medical devices under magnetic resonance imaging exposure. The strategy uses the particle swarm optimization (PSO) algorithm to generate optimized rotation-invariant lead trajectories for arbitrary lead lengths in a rectangular phantom. The validation trajectories are generated by rotating a PSO optimized trajectory on a circular plate. The incident electric fields along these trajectories are minimally correlated resulting in very accurate validation. Compared with other validation trajectories used in the literature and recommended by ISO/TS 10974, the new method is significantly more robust, effective, accurate, and time efficient; and therefore, an ideal candidate for standardization.


  • Dual-Frequency High-Electric-Field Generator for MRI Safety Testing of Passive Implantable Medical Devices

    by Shuo Song, Jianfeng Zheng, Yu Wang, Qingyan Wang, Wolfgang Kainz, Stuart A. Long, Ji Chen

    In this article, an electric (E) field generator is developed to generate uniform and high-strength E-fields at multiple frequencies. The system can be used to assess the radio frequency (RF) hazards of implantable medical devices (IMDs) in magnetic resonance imaging (MRI) environments. The novel system consists of three parts: 1) a signal generating and amplifying block; 2) a four-channel feeding network; and 3) a rectangular resonator box. Mixed modes are utilized to generate locally uniform E-fields inside the rectangular resonator at both 64 and 128 MHz. RF-induced heating for two passive IMD families are evaluated using both numerical and experimental methods inside the E-field generator. These results are compared with those obtained from standard American Society of Testing and Materials (ASTM) phantom testing. The results show that the novel E-field generator is capable of evaluating RF-induced heating for passive IMDs similar to that of the ASTM phantom. Furthermore, it integrates both 1.5- and 3-T RF-induced heating tests in a single system. It is much simpler compared to the ASTM test method which needs the RF coil as a source. Consequently, this small and efficient E-field generator can be used as an alternative system for RF-induced heating tests of passive IMDs in the MRI environment.


  • Erratum to “On the Model Validation of Active Implantable Medical Device for MRI Safety Assessment”

    by Zhichao Wang, Jianfeng Zheng, Yu Wang, Wolfgang Kainz, Ji Chen

    In the original article [1] , a declaration of financial interest is missing. The declaration is given as follows:

  • A Novel Device Model Validation Strategy for 1.5- and 3-T MRI Heating Safety Assessment

    by Yu Wang, Shuo Song, Jianfeng Zheng, Qingyan Wang, Stuart A. Long, Wolfgang Kainz, Ji Chen

    This paper presents a novel test instrument and strategy for active implantable medical device (AIMD) model validation under a radio-frequency (RF) field generated by a magnetic resonance imaging (MRI) system. A high electric field generator is developed as an alternative instrument for standard MRI RF coils. This system is both compact and power efficient. In addition, a set of validation pathways are proposed based on the Hadamard matrix. These pathways provide low correlations among incident electric fields and yet generate relative high temperature rises. Two generic AIMDs with different lengths are used to validate the strategy experimentally. It is demonstrated that this method provides an efficient and effective alternative for future AIMDs model validation under MRI RF emissions.