Brian Eng
Research Subjects
Research Interests
Brian Eng has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Probir K. Ghoshal
Jefferson Lab, Newport News, VA, USA
3 shared publications - Michael P. Dion
Jefferson Lab, Newport News, VA, USA
2 shared publications - Renuka Rajput-Ghoshal
Jefferson Lab, Newport News, VA, USA
2 shared publications - Sandesh Gopinath
Jefferson Lab, Newport News, VA, USA
2 shared publications Aaron Brown
Magnet Group, Experimental Nuclear Physics Division, Jefferson Lab, Newport News, VA, USA
1 shared publication- B. U. Don
Department of Physics and Astronomy, University of Manitoba 4 , Winnipeg, Manitoba R3T 2N2
1 shared publication
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Measurement of a lepton–lepton electroweak reaction (MOLLER) spectrometer magnet—Magnetic field measurement and analysis at Jefferson lab
The Thomas Jefferson National Accelerator Facility has developed a specialized spectrometer system for the MOLLER (Measurement Of a Lepton Lepton Electroweak Reaction) experiment, which is designed to probe weak interactions between electrons using 12 GeV electron LINAC. Scheduled to operate over a three-year period, the experiment relies on five water-cooled toroidal magnets—each with seven-fold symmetry and unique geometry—engineered to focus scattered particles. These magnets generate the magnetic field necessary to separate Moller-scattered electrons from elastically scattered protons within the liquid hydrogen target. To meet physics requirements for the experiment, the field in the bore of each magnet must be low enough to not interfere with the scattered protons and generate unwanted backgrounds downstream. This paper presents an engineering-focused evaluation of the magnetic field mapping process, comparing the measured fields with the design specifications and the simulated fields in the bore. The resulting field maps are intended for use in GEANT4 simulations, where precision is critical due to the challenges of low-field measurements. The field analysis will quantify the differences between the ideal and measured magnetic fields. The final field-mapping data will then be used to verify how well the original engineering assumptions performed in generating field inputs for “ee and ep” tracking simulations.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Measurement of a lepton–lepton electroweak reaction (MOLLER) spectrometer magnet—Magnetic field measurement and analysis at Jefferson lab
The Thomas Jefferson National Accelerator Facility has developed a specialized spectrometer system for the MOLLER (Measurement Of a Lepton Lepton Electroweak Reaction) experiment, which is designed to probe weak interactions between electrons using 12 GeV electron LINAC. Scheduled to operate over a three-year period, the experiment relies on five water-cooled toroidal magnets—each with seven-fold symmetry and unique geometry—engineered to focus scattered particles. These magnets generate the magnetic field necessary to separate Moller-scattered electrons from elastically scattered protons within the liquid hydrogen target. To meet physics requirements for the experiment, the field in the bore of each magnet must be low enough to not interfere with the scattered protons and generate unwanted backgrounds downstream. This paper presents an engineering-focused evaluation of the magnetic field mapping process, comparing the measured fields with the design specifications and the simulated fields in the bore. The resulting field maps are intended for use in GEANT4 simulations, where precision is critical due to the challenges of low-field measurements. The field analysis will quantify the differences between the ideal and measured magnetic fields. The final field-mapping data will then be used to verify how well the original engineering assumptions performed in generating field inputs for “ee and ep” tracking simulations.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The “Measurement of Lepton-Lepton Electroweak Reaction” (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. The magnetic field generated by the Spectrometer is needed to separate the incident beam electrons that scatter from target electrons (Moller scattering) from the protons due to elastic e-p scattering within a liquid hydrogen target. This paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The “Measurement of Lepton-Lepton Electroweak Reaction” (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. The magnetic field generated by the Spectrometer is needed to separate the incident beam electrons that scatter from target electrons (Moller scattering) from the protons due to elastic e-p scattering within a liquid hydrogen target. This paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 124701
Development of FPGA-based multi-sensor excitation low voltage (MSELV) chassis at Jefferson Lab
The design and development of the sensor excitation and read back chassis was driven by the requirements for the monitoring and control of two conduction-cooled superconducting magnets in Hall B for the 12 GeV accelerator upgrade. The torus and solenoid superconducting magnets require extensive instrumentation. Sensor selection was accomplished by applying Jefferson Lab’s (JLab) risk mitigation process, which employed a failure modes and effects analysis approach. The goal was to accommodate all sensor types for monitoring and control and to develop a generic multisensor excitation low voltage chassis that would be used across both magnet systems with a reduced set of functions. The chassis has been deployed in experimental Hall B at JLab and has been performing successfully since July 2016.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 124701
Development of FPGA-based multi-sensor excitation low voltage (MSELV) chassis at Jefferson Lab
The design and development of the sensor excitation and read back chassis was driven by the requirements for the monitoring and control of two conduction-cooled superconducting magnets in Hall B for the 12 GeV accelerator upgrade. The torus and solenoid superconducting magnets require extensive instrumentation. Sensor selection was accomplished by applying Jefferson Lab’s (JLab) risk mitigation process, which employed a failure modes and effects analysis approach. The goal was to accommodate all sensor types for monitoring and control and to develop a generic multisensor excitation low voltage chassis that would be used across both magnet systems with a reduced set of functions. The chassis has been deployed in experimental Hall B at JLab and has been performing successfully since July 2016.