MSMargareth Maria Gomes de Souza

Margareth Maria Gomes de Souza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Margareth Maria Gomes de Souza has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Surface Roughness, Biofilm Accumulation, and Acidogenic Potential of Esthetic Orthodontic Brackets Exposed to Cigarette Smoke

    by Kelly Galisteu-Luiz, Flávio de Mendonça Copello, Karla Lorene de França Leite, Luíza Trindade Vilela, Mylena da Rocha Cavalcante, Sarah Pereira Martins, Kenderson Santos Silva, Gabriela Drago Vidal, Carlos Nelson Elias, Luísa Schubach da Costa Barreto, et al.

    Purpose: To evaluate the effect of cigarette smoke on esthetic brackets. Methods: Four commercial brackets ( n = 112), Ceramic ® , Composite ® , PolySafira ® , and Zetta ® were exposed for 21 consecutive days to cigarette smoke. The control group consisted of each bracket material maintained in artificial saliva and not exposed to cigarette smoke. Linear surface roughness was measured before and after exposure using optical profilometry, and surface morphology was qualitatively characterized by scanning electron microscopy (SEM) after the exposure period. Subsequently, the brackets were subjected to an acidogenic challenge in a multispecies biofilm with 2% sucrose. After 48 h, biofilm viability was assessed (CFU/mL), and the culture medium pH was analyzed. The data were analyzed using the Kruskal–Wallis test followed by the Mann–Whitney U test with Bonferroni correction, and a paired t -test ( p < .05). Results: Zetta ® showed the greatest increase in Ra (+0.27 µm), and Ceramic ® exhibited a slight increase (+0.06 µm). Composite ® and PolySafira ® demonstrated a reduction in Ra values ( p < .05). Composite ® accumulated the highest amount of viable biofilm (6.44 × 10 4 CFU/mL), whereas Ceramic ® presented the lowest (3.56 × 10 4 CFU/mL). All groups showed a significant pH reduction after biofilm formation, with Composite ® demonstrating the most pronounced acidification (pH 6.5–5.2) and Ceramic ® the least (pH 6.8–5.9). Conclusions: Cigarette smoke exposure adversely affected surface characteristics and acidogenic potential in esthetic orthodontic brackets. Ceramic ® showed lower biofilm accumulation and less pronounced surface roughness changes, while PolySafira ® showed stable surface behavior, and Zetta ® and Composite ® were more susceptible to surface alterations and biological challenges.

  • Open Access

    Cleaning solutions for orthodontic clear aligners

    by Luísa Schubach da Costa Barreto, Karla Lorene de França Leite, Catarina Saadi Miguez Ribeiro, Millene de Oliveira Dias, Fernanda Oliveira Miranda Tavares, Mylena da Rocha Cavalcante, Sarah Pereira Martins, Kenderson Santos Silva, Margareth Maria Gomes de Souza

  • Evaluation of enamel surface after removal of clear aligner composite attachments using different methods: An in-vitro randomised study

    by Bruna Caroline Tomé Barreto, Gabriela Drago Vidal, Eduardo Franzotti Sant’ANna, Amanda Cunha Regal de Castro, Mônica Tirre de Souza Araújo, Matheus Melo Pithon, Margareth Maria Gomes de Souza

    Objective: To evaluate bovine enamel surfaces after removal of clear aligner composite attachments using different methods, considering temperature, noise and vibration generated by rotating instruments. The null hypothesis stated that there would be no differences among methods. Material and methods: A total of 56 specimens were randomly assigned to seven groups according to the removal technique: pencil-tip diamond bur at high-speed (CG); latch-lock multiblade bur at low-speed (LG); friction-grip multiblade bur at high-speed without irrigation (HG); friction-grip multiblade bur at high-speed with irrigation (HIG); aluminium-oxide tips at low-speed (AOG); Sof-Lex™ Pop-On discs at low-speed (SLG), applied from coarse to fine; and Enhance silicone tips at low-speed (EG). Surface roughness was measured using a 3D optical profilometer (Nanovea PS50) and microhardness with a Knoop microhardness tester (Buehler MICROMET 5104). During composite removal, temperature was monitored with a digital infrared thermometer (Lasergrip GM 400), noise with a decibel metre (DL-1100), and vibration with a vibration metre (WT63A). Results: AOG produced the highest mean vibration (2.6 ± 0.4 mm/s; P < 0.001), LG generated the highest mean temperature (31 ± 1.2°C; P < 0.001) and CG produced the highest mean noise levels (90.3 ± 2.1 dB; P < 0.001). SLG showed the smallest mean change in roughness (ΔRa: 0.46 ± 0.57). Conclusion: All removal methods increased enamel roughness and reduced microhardness, with significant differences in temperature, noise and vibration. AOG and SLG caused less enamel damage and better surface preservation, indicating they may represent safer clinical options. The null hypothesis was therefore rejected.

  • Open Access

    Three-dimensional accuracy of in-office aligner therapy: a retrospective comparison between planned and achieved tooth positions

    by Clara Ribeiro de Souza, Bruna Caroline Tomé Barreto, Luísa Schubach da Costa Barreto, Carlo Marassi, Antônio Carlos de Oliveira Ruellas, Margareth Maria Gomes de Souza

  • Open Access

    Effect of cigarette smoke on surface roughness and bacterial adhesion of orthodontic aligners: an in vitro investigation

    by Kelly Galisteu-Luiz, Flávio de Mendonça Copello, Karla Lorene de França Leite, Mylena da Rocha Cavalcante, Larine Ferreira Lira, Kenderson Santos Silva, Sarah Pereira Martins, Ingrid Cristina Pinto da Costa, Gabriela Drago Vidal, Carlos Nelson Elias, et al.

    Objectives: This study aims to evaluate the impact of cigarette smoke on Invisalign ® aligners in surface roughness, bacterial adherence rates, pH changes and multispecies biofilm formation after exposure. Materials and Methods: Seventy-two flat samples of growth (G1), sterility (G2), saliva (G3), and smoke (G4) groups were exposed to artificial saliva, and G4 underwent 21 cycles of smoke. Linear roughness (Ra) and average depth (Rz) were assessed before and after saliva (G3.1) and smoke (G4.1) exposure. Independent and paired t-tests compared measurements over 5 days of evaluation [biofilm, microorganisms (CFU/mL), pH, and volumetric surface roughness (Sa)], measurements were taken before (T0) and after (T1) exposure to saliva and cigarette smoke. Results: Increased roughness post-exposure to cigarette smoke Ra (p = 0.003) and Rz (p = 0.014) in G4.1 at T1 (p = 0.046), and higher roughness over time (Ra: 0.139 ± 0.007; Rz: 0.741 ± 0.026), unlike G3.1 (Ra: 0.122 ± 0.002; Rz: 0.616 ± 0.021). G1 had the highest CFU (8.57 × 108), significantly higher than the G4.2 (5.33 × 108) and G3.2 (2 × 108). From 24 to 96 h, pH in G4.2 (5.75) and G1 (4.45) showed slight decreases, G2 (6.76) and G3.2 (6.35) increased. G1 had the highest Sa (48.97 ± 14.19), compared to G2 (4.27 ± 1.14), G3 (7.60 ± 4.28), and G4 (13.98 ± 8.18). Conclusions: Cigarette smoke exposure elevated surface roughness and enhanced bacterial adherence on aligners. Clinical Relevance: Reinforce smoking cessation and strict oral hygiene protocols for aligner-wearing patients. In vivo studies are warranted to confirm these findings.


  • Effect of cigarette smoke on the optical properties of clear orthodontic aligners: an in-vitro study

    by Kelly Galisteu-Luiz, Flávio de Mendonça Copello, Larine Ferreira Lira, Luísa Schubach da Costa Barreto, Ingrid Cristina Pinto da Costa, Carlos Nelson Elias, Margareth Maria Gomes de Souza

    Aim: This study assessed the optical properties of aligner surfaces post-cigarette smoke exposure. Design: In-vitro experimental study. Setting: Laboratory analysis of clear aligners subjected to cigarette smoke exposure at Federal University of Rio de Janeiro, Brazil. Methods: A total of 20 plastic pieces from the labial surfaces of upper central incisors of Invisalign ® clear aligners were randomly divided into a control group (CG) and an experimental group (EG). The specimens were divided equally (n = 10): CG, stored in artificial saliva at 37°C ± 1°C for 14 days; and the EG, exposed to cigarette smoke using a sealed acrylic device with 10 cigarettes per cycle for 20 cycles. A spectrophotometer was used to evaluate changes in colour and light transmittance based on CIELab* colour parameters. Measurements were taken before (T0) and after (T1) exposure. The total colour difference (∆E) and National Bureau of Standards (NBS) were calculated. T-tests were used for comparisons at a significance level of 0.05. Results: Statistically significant colour changes ( P < 0.05) were observed at T1 in the EG (luminosity [L*] = 77.20 ± 3.33; difference along green-red axis [a*] = −1.57 ± 0.02; and difference along blue-yellow axis [b*] = 6.74 ± 0.55) compared to the CG. The mean ∆E* value at T1 was significantly higher in the EG (14.27 ± 2.72) compared to the CG (2.39 ± 0.56; P = 0.002). Light transmittance decreased significantly after cigarette smoke exposure (CG = 68.396 ± 8.683; EG = 59.538 ± 5.089; P = 0.012). Conclusions: Cigarette smoke exposure significantly altered the optical properties of clear orthodontic aligners, affecting both colour and light transmittance.


  • Open Access

    Influence of low viscosity resin infiltrant on the adhesion of orthodontic attachments

    by Bruna Caroline Tomé Barreto, Gabriela Drago Vidal, Katherine Judith de Carvalho Macário Presado Silver, Karla Lorene de França Leite, Carolina Mara Geraldino Monteiro, Matheus Melo Pithon, Margareth Maria Gomes de Souza

    Introduction: The search for materials and techniques that promote better adhesion to enamel previously affected by carious lesions has intensified in orthodontics, especially with the use of infiltrating resins and composites with different characteristics. Objective: To evaluate the adhesion of orthodontic attachments made with different composites bonded to previously infiltrated enamel. Methods: Ninety bovine lower incisors were randomly divided into 6 groups (n=15): 1 control Z350 (group C) and 5 experimental: Z350 (group Z), bulk fill - 3M (group FM), bulk fill flow - 3M (group FFM), bulk fill - FGM (group FF), bulk fill flow - FGM (FFF). Each group differed by the type of composite used to attachment. Only the experimental groups were subjected to cariogenic challenge followed by treatment with Icon, a low viscosity resinous infiltrant. After aging, orthodontic attachments were bonded to all specimens (n=90) and a mechanical shear bond strength test was performed with subsequent analysis of the adhesive remnant index (ARI). Data were analyzed using Jamovi software version 2.3 with a significance level of 5%. Descriptive statistics (means and standard deviations), normality test and ANOVA/Tukey for shear variables and Kruskal-Wallis test for ARI were performed. Results: The control group required greater force to shear the attachment (100N ± 32.6; p= 0.016), while the group that used the Bulk Fill Flow FGM composite required less force (55.6N ± 22.5; p= 0.016). Conclusion: The presence of resin infiltrant influenced the adhesion of orthodontic attachments, made with different composites. However, it did not interfere with ARI.

  • Open Access

    Effect of 35% hydrogen peroxide in promoting enamel whitening with orthodontic attachments bonded on its surface

    by Bruna Caroline Tomé Barreto, Luiza Trindade Vilela, Guido Artemio Marañón-Vásquez, Matheus Melo Pithon, Margareth Maria Gomes de Souza

    Introduction: The demand for aesthetics is high and the desire for white teeth during orthodontic treatment is a desire of patients. Objective: To evaluate the effect of 35% hydrogen peroxide in promoting enamel whitening with orthodontic attachments bonded to its surface. Methods: 80 bovine incisors randomly divided into 4 groups (n=20): (GI) control group, (GII) group that received only tooth whitening, (GIII) group that received only bonding of attachments on the surface and (GIV) group that received bonding of attachments and whitening. Whitening was carried out following the manufacturer’s instructions while the attachments were bonded to the dental surface using a template after acid conditioning of the enamel and application of an adhesive system. Color evaluation was performed according to the LAB color scale of the Commission Internationale de l’Eclairage. Statistical analysis was performed using Jamovi program adopting a 5% significance level. Descriptive data analysis was performed, characterizing all study variables. General linear models adjusted by ordinary least squares regression were used to test the effect of whitening, enhancement use, and the interaction of both factors. Results: Both “whitening” and the use of “attachments” have an effect on all parameters of the CIELAB scale (keeping the other variable constant). The whitening effect was independent of the presence of attachments. Conclusion: 35% hydrogen peroxide is capable of promoting enamel whitening with orthodontic attachments bonded to its surface. Clinical Meaning: Despite being in vitro research, the study provides patients and professionals with the possibility of teeth whitening during orthodontic treatment with aligners.


  • Open Access

    Perfil por raça/cor de usuários de um serviço de referência em fissuras labiopalatinas: estudo transversal

    by Ana Maria Bezerra Bandeira, Márcia Pereira Alves Dos Santos, Danielle Amaral De Freitas, Luísa Schubach da Costa Barreto, Bruna Caroline Tomé Barreto, Antônio Carlos de Oliveira Ruellas, Margareth Maria Gomes De Souza

    Objetivou-se investigar o perfil de usuários por raça/cor atendidos em um centro referência para tratamento de fissura labiopalatina no Rio de Janeiro. A coleta de dados ocorreu pelas informações extraídas do prontuário e da aplicação de um questionário aos pacientes ou responsáveis, quando necessário. Os dados foram tratados com testes estatísticos pertinentes. A maioria dos usuários era negra (71,6%), do sexo masculino (55,2%), na faixa etária de 0 a 3 anos (32,3%) e renda familiar de até 2 salários mínimos (61,2%) com número da mediana de membros da família de 4 pessoas. A fissura transforame incisivo foi a mais frequente (58,2%). Houve associação significativa entre sexo e tipo de fissura, com a fissura transforame predominando em homens (63,2%). O intervalo entre o nascimento e a primeira consulta foi mais prolongado para os usuários negros. Os resultados apontam para a urgência de intervenções precoces e equitativas. Tais medidas podem englobar iniciativas desde a conscientização sobre a importância do diagnóstico precoce até estratégias voltadas à redução do tempo decorrido entre o nascimento e o acesso ao atendimento especializado. Limitações incluíram a incerteza na autodeclaração racial e o número menor de respondentes do que o estimado.

  • Open Access

    Does mandibular advancement ortho-surgical procedure cause condyle changes? A case-series analysis

    by Alline Birra Nolasco Fernandes, Luíza Trindade Vilela, Taísa Figueiredo Chagas, Antônio Carlos de Oliveira Ruellas, Cláudia Trindade Mattos, Margareth Maria Gomes de Souza

    Introduction: Mandibular advancement surgery corrects bone bases while establishing patients’ functional and aesthetic rehabilitation. However, little is known about the results of this procedure in the structures that make up the stomatognathic system, as the condyles. Objective: This study aimed to evaluate the structural and positional changes of mandibular condyles in ortho-surgical patients who underwent mandibular advancement surgery. Material and Methods: A prospective investigation was conducted with cone-beam computed tomography images. Using Dolphin Imaging® software, seven ortho-surgical patients with Angle Class II malocclusion and mandibular deficiency were evaluated. The images assessed were obtained at pre-surgical phase and after, at least, 1 year of the procedure. To study the structural and positional changes of condyles, linear and angular measurements were obtained, and the right and left sides of patients were compared. Descriptive statistical analysis was performed and, in order to verify possible significant differences, normality tests (Kolmogorov-Smirnov) were applied, followed by a paired t-test to define significance. Results: For all measures evaluated in this study, no statistically significant differences were found. Conclusion: The ortho-surgical procedure performed did not change the structure and position of the condyles of patients who underwent surgical mandibular advancement. Right and left mandibular condyles behaved similarly, suggesting stability and condylar adaptation after surgery.