Gabriela Drago Vidal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gabriela Drago Vidal has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Margareth Maria Gomes de Souza
Federal University of Rio de Janeiro, Brazil
4 shared publications - Bruna Caroline Tomé Barreto
Federal University of Rio de Janeiro, Brazil
2 shared publications - Carlos Nelson Elias
Materials Science Department, Instituto Militar de Engenharia, Rio de Janeiro 22290-270, Brazil
2 shared publications - Flávio de Mendonça Copello
Department of Orthodontics and Pediatric Dentistry, School of Dentistry, University of Maryland, Baltimore, MD, USA
2 shared publications - Karla Lorene de França Leite
Universidade Federal do Rio de Janeiro, Brazil
2 shared publications - Kelly Galisteu-Luiz
Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil
2 shared publications
Latest Publications
- Open Access
- 6 September 2026
- Published by SAGE Publications in Journal of Applied Dentistry and Oral Sciences
Surface Roughness, Biofilm Accumulation, and Acidogenic Potential of Esthetic Orthodontic Brackets Exposed to Cigarette Smoke
Purpose: To evaluate the effect of cigarette smoke on esthetic brackets. Methods: Four commercial brackets ( n = 112), Ceramic ® , Composite ® , PolySafira ® , and Zetta ® were exposed for 21 consecutive days to cigarette smoke. The control group consisted of each bracket material maintained in artificial saliva and not exposed to cigarette smoke. Linear surface roughness was measured before and after exposure using optical profilometry, and surface morphology was qualitatively characterized by scanning electron microscopy (SEM) after the exposure period. Subsequently, the brackets were subjected to an acidogenic challenge in a multispecies biofilm with 2% sucrose. After 48 h, biofilm viability was assessed (CFU/mL), and the culture medium pH was analyzed. The data were analyzed using the Kruskal–Wallis test followed by the Mann–Whitney U test with Bonferroni correction, and a paired t -test ( p < .05). Results: Zetta ® showed the greatest increase in Ra (+0.27 µm), and Ceramic ® exhibited a slight increase (+0.06 µm). Composite ® and PolySafira ® demonstrated a reduction in Ra values ( p < .05). Composite ® accumulated the highest amount of viable biofilm (6.44 × 10 4 CFU/mL), whereas Ceramic ® presented the lowest (3.56 × 10 4 CFU/mL). All groups showed a significant pH reduction after biofilm formation, with Composite ® demonstrating the most pronounced acidification (pH 6.5–5.2) and Ceramic ® the least (pH 6.8–5.9). Conclusions: Cigarette smoke exposure adversely affected surface characteristics and acidogenic potential in esthetic orthodontic brackets. Ceramic ® showed lower biofilm accumulation and less pronounced surface roughness changes, while PolySafira ® showed stable surface behavior, and Zetta ® and Composite ® were more susceptible to surface alterations and biological challenges.
- 6 September 2026
- Published by SAGE Publications in Journal of Applied Dentistry and Oral Sciences
Open AccessSurface Roughness, Biofilm Accumulation, and Acidogenic Potential of Esthetic Orthodontic Brackets Exposed to Cigarette Smoke
Purpose: To evaluate the effect of cigarette smoke on esthetic brackets. Methods: Four commercial brackets ( n = 112), Ceramic ® , Composite ® , PolySafira ® , and Zetta ® were exposed for 21 consecutive days to cigarette smoke. The control group consisted of each bracket material maintained in artificial saliva and not exposed to cigarette smoke. Linear surface roughness was measured before and after exposure using optical profilometry, and surface morphology was qualitatively characterized by scanning electron microscopy (SEM) after the exposure period. Subsequently, the brackets were subjected to an acidogenic challenge in a multispecies biofilm with 2% sucrose. After 48 h, biofilm viability was assessed (CFU/mL), and the culture medium pH was analyzed. The data were analyzed using the Kruskal–Wallis test followed by the Mann–Whitney U test with Bonferroni correction, and a paired t -test ( p < .05). Results: Zetta ® showed the greatest increase in Ra (+0.27 µm), and Ceramic ® exhibited a slight increase (+0.06 µm). Composite ® and PolySafira ® demonstrated a reduction in Ra values ( p < .05). Composite ® accumulated the highest amount of viable biofilm (6.44 × 10 4 CFU/mL), whereas Ceramic ® presented the lowest (3.56 × 10 4 CFU/mL). All groups showed a significant pH reduction after biofilm formation, with Composite ® demonstrating the most pronounced acidification (pH 6.5–5.2) and Ceramic ® the least (pH 6.8–5.9). Conclusions: Cigarette smoke exposure adversely affected surface characteristics and acidogenic potential in esthetic orthodontic brackets. Ceramic ® showed lower biofilm accumulation and less pronounced surface roughness changes, while PolySafira ® showed stable surface behavior, and Zetta ® and Composite ® were more susceptible to surface alterations and biological challenges.
- 27 May 2026
- Published by SAGE Publications in Journal of Orthodontics
- Vol. 53 (3) , 215-225
Evaluation of enamel surface after removal of clear aligner composite attachments using different methods: An in-vitro randomised study
Objective: To evaluate bovine enamel surfaces after removal of clear aligner composite attachments using different methods, considering temperature, noise and vibration generated by rotating instruments. The null hypothesis stated that there would be no differences among methods. Material and methods: A total of 56 specimens were randomly assigned to seven groups according to the removal technique: pencil-tip diamond bur at high-speed (CG); latch-lock multiblade bur at low-speed (LG); friction-grip multiblade bur at high-speed without irrigation (HG); friction-grip multiblade bur at high-speed with irrigation (HIG); aluminium-oxide tips at low-speed (AOG); Sof-Lex™ Pop-On discs at low-speed (SLG), applied from coarse to fine; and Enhance silicone tips at low-speed (EG). Surface roughness was measured using a 3D optical profilometer (Nanovea PS50) and microhardness with a Knoop microhardness tester (Buehler MICROMET 5104). During composite removal, temperature was monitored with a digital infrared thermometer (Lasergrip GM 400), noise with a decibel metre (DL-1100), and vibration with a vibration metre (WT63A). Results: AOG produced the highest mean vibration (2.6 ± 0.4 mm/s; P < 0.001), LG generated the highest mean temperature (31 ± 1.2°C; P < 0.001) and CG produced the highest mean noise levels (90.3 ± 2.1 dB; P < 0.001). SLG showed the smallest mean change in roughness (ΔRa: 0.46 ± 0.57). Conclusion: All removal methods increased enamel roughness and reduced microhardness, with significant differences in temperature, noise and vibration. AOG and SLG caused less enamel damage and better surface preservation, indicating they may represent safer clinical options. The null hypothesis was therefore rejected.
- 27 May 2026
- Published by SAGE Publications in Journal of Orthodontics
- Vol. 53 (3) , 215-225
Evaluation of enamel surface after removal of clear aligner composite attachments using different methods: An in-vitro randomised study
Objective: To evaluate bovine enamel surfaces after removal of clear aligner composite attachments using different methods, considering temperature, noise and vibration generated by rotating instruments. The null hypothesis stated that there would be no differences among methods. Material and methods: A total of 56 specimens were randomly assigned to seven groups according to the removal technique: pencil-tip diamond bur at high-speed (CG); latch-lock multiblade bur at low-speed (LG); friction-grip multiblade bur at high-speed without irrigation (HG); friction-grip multiblade bur at high-speed with irrigation (HIG); aluminium-oxide tips at low-speed (AOG); Sof-Lex™ Pop-On discs at low-speed (SLG), applied from coarse to fine; and Enhance silicone tips at low-speed (EG). Surface roughness was measured using a 3D optical profilometer (Nanovea PS50) and microhardness with a Knoop microhardness tester (Buehler MICROMET 5104). During composite removal, temperature was monitored with a digital infrared thermometer (Lasergrip GM 400), noise with a decibel metre (DL-1100), and vibration with a vibration metre (WT63A). Results: AOG produced the highest mean vibration (2.6 ± 0.4 mm/s; P < 0.001), LG generated the highest mean temperature (31 ± 1.2°C; P < 0.001) and CG produced the highest mean noise levels (90.3 ± 2.1 dB; P < 0.001). SLG showed the smallest mean change in roughness (ΔRa: 0.46 ± 0.57). Conclusion: All removal methods increased enamel roughness and reduced microhardness, with significant differences in temperature, noise and vibration. AOG and SLG caused less enamel damage and better surface preservation, indicating they may represent safer clinical options. The null hypothesis was therefore rejected.
- Open Access
- 17 January 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (1) , 55
Effect of cigarette smoke on surface roughness and bacterial adhesion of orthodontic aligners: an in vitro investigation
Objectives: This study aims to evaluate the impact of cigarette smoke on Invisalign ® aligners in surface roughness, bacterial adherence rates, pH changes and multispecies biofilm formation after exposure. Materials and Methods: Seventy-two flat samples of growth (G1), sterility (G2), saliva (G3), and smoke (G4) groups were exposed to artificial saliva, and G4 underwent 21 cycles of smoke. Linear roughness (Ra) and average depth (Rz) were assessed before and after saliva (G3.1) and smoke (G4.1) exposure. Independent and paired t-tests compared measurements over 5 days of evaluation [biofilm, microorganisms (CFU/mL), pH, and volumetric surface roughness (Sa)], measurements were taken before (T0) and after (T1) exposure to saliva and cigarette smoke. Results: Increased roughness post-exposure to cigarette smoke Ra (p = 0.003) and Rz (p = 0.014) in G4.1 at T1 (p = 0.046), and higher roughness over time (Ra: 0.139 ± 0.007; Rz: 0.741 ± 0.026), unlike G3.1 (Ra: 0.122 ± 0.002; Rz: 0.616 ± 0.021). G1 had the highest CFU (8.57 × 108), significantly higher than the G4.2 (5.33 × 108) and G3.2 (2 × 108). From 24 to 96 h, pH in G4.2 (5.75) and G1 (4.45) showed slight decreases, G2 (6.76) and G3.2 (6.35) increased. G1 had the highest Sa (48.97 ± 14.19), compared to G2 (4.27 ± 1.14), G3 (7.60 ± 4.28), and G4 (13.98 ± 8.18). Conclusions: Cigarette smoke exposure elevated surface roughness and enhanced bacterial adherence on aligners. Clinical Relevance: Reinforce smoking cessation and strict oral hygiene protocols for aligner-wearing patients. In vivo studies are warranted to confirm these findings.
- 17 January 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (1) , 55
Open AccessEffect of cigarette smoke on surface roughness and bacterial adhesion of orthodontic aligners: an in vitro investigation
Objectives: This study aims to evaluate the impact of cigarette smoke on Invisalign ® aligners in surface roughness, bacterial adherence rates, pH changes and multispecies biofilm formation after exposure. Materials and Methods: Seventy-two flat samples of growth (G1), sterility (G2), saliva (G3), and smoke (G4) groups were exposed to artificial saliva, and G4 underwent 21 cycles of smoke. Linear roughness (Ra) and average depth (Rz) were assessed before and after saliva (G3.1) and smoke (G4.1) exposure. Independent and paired t-tests compared measurements over 5 days of evaluation [biofilm, microorganisms (CFU/mL), pH, and volumetric surface roughness (Sa)], measurements were taken before (T0) and after (T1) exposure to saliva and cigarette smoke. Results: Increased roughness post-exposure to cigarette smoke Ra (p = 0.003) and Rz (p = 0.014) in G4.1 at T1 (p = 0.046), and higher roughness over time (Ra: 0.139 ± 0.007; Rz: 0.741 ± 0.026), unlike G3.1 (Ra: 0.122 ± 0.002; Rz: 0.616 ± 0.021). G1 had the highest CFU (8.57 × 108), significantly higher than the G4.2 (5.33 × 108) and G3.2 (2 × 108). From 24 to 96 h, pH in G4.2 (5.75) and G1 (4.45) showed slight decreases, G2 (6.76) and G3.2 (6.35) increased. G1 had the highest Sa (48.97 ± 14.19), compared to G2 (4.27 ± 1.14), G3 (7.60 ± 4.28), and G4 (13.98 ± 8.18). Conclusions: Cigarette smoke exposure elevated surface roughness and enhanced bacterial adherence on aligners. Clinical Relevance: Reinforce smoking cessation and strict oral hygiene protocols for aligner-wearing patients. In vivo studies are warranted to confirm these findings.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 30 (5) , e2525126
Influence of low viscosity resin infiltrant on the adhesion of orthodontic attachments
Introduction: The search for materials and techniques that promote better adhesion to enamel previously affected by carious lesions has intensified in orthodontics, especially with the use of infiltrating resins and composites with different characteristics. Objective: To evaluate the adhesion of orthodontic attachments made with different composites bonded to previously infiltrated enamel. Methods: Ninety bovine lower incisors were randomly divided into 6 groups (n=15): 1 control Z350 (group C) and 5 experimental: Z350 (group Z), bulk fill - 3M (group FM), bulk fill flow - 3M (group FFM), bulk fill - FGM (group FF), bulk fill flow - FGM (FFF). Each group differed by the type of composite used to attachment. Only the experimental groups were subjected to cariogenic challenge followed by treatment with Icon, a low viscosity resinous infiltrant. After aging, orthodontic attachments were bonded to all specimens (n=90) and a mechanical shear bond strength test was performed with subsequent analysis of the adhesive remnant index (ARI). Data were analyzed using Jamovi software version 2.3 with a significance level of 5%. Descriptive statistics (means and standard deviations), normality test and ANOVA/Tukey for shear variables and Kruskal-Wallis test for ARI were performed. Results: The control group required greater force to shear the attachment (100N ± 32.6; p= 0.016), while the group that used the Bulk Fill Flow FGM composite required less force (55.6N ± 22.5; p= 0.016). Conclusion: The presence of resin infiltrant influenced the adhesion of orthodontic attachments, made with different composites. However, it did not interfere with ARI.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 30 (5) , e2525126
Open AccessInfluence of low viscosity resin infiltrant on the adhesion of orthodontic attachments
Introduction: The search for materials and techniques that promote better adhesion to enamel previously affected by carious lesions has intensified in orthodontics, especially with the use of infiltrating resins and composites with different characteristics. Objective: To evaluate the adhesion of orthodontic attachments made with different composites bonded to previously infiltrated enamel. Methods: Ninety bovine lower incisors were randomly divided into 6 groups (n=15): 1 control Z350 (group C) and 5 experimental: Z350 (group Z), bulk fill - 3M (group FM), bulk fill flow - 3M (group FFM), bulk fill - FGM (group FF), bulk fill flow - FGM (FFF). Each group differed by the type of composite used to attachment. Only the experimental groups were subjected to cariogenic challenge followed by treatment with Icon, a low viscosity resinous infiltrant. After aging, orthodontic attachments were bonded to all specimens (n=90) and a mechanical shear bond strength test was performed with subsequent analysis of the adhesive remnant index (ARI). Data were analyzed using Jamovi software version 2.3 with a significance level of 5%. Descriptive statistics (means and standard deviations), normality test and ANOVA/Tukey for shear variables and Kruskal-Wallis test for ARI were performed. Results: The control group required greater force to shear the attachment (100N ± 32.6; p= 0.016), while the group that used the Bulk Fill Flow FGM composite required less force (55.6N ± 22.5; p= 0.016). Conclusion: The presence of resin infiltrant influenced the adhesion of orthodontic attachments, made with different composites. However, it did not interfere with ARI.