Zihao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zihao Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Huichan Zhao
Tsinghua University
2 shared publications - Zhenguo Nie
Tsinghua University
2 shared publications - Fugui Xie
Tsinghua University
1 shared publication - Li Liu
School of Advanced Engineering and Dongguan Great Bay Institute for Advanced Study, Great Bay University, Dongguan, China
1 shared publication - Max Qing-Hu Meng
Southern University of Science and Technology, Shenzhen, China
1 shared publication Qi Shao
Department of Mechanical Engineering, State Key Laboratory of Tribology in Advanced Equipment, Beijing Key Laboratory of Transformative High-end Manufacturing Equipment and Technology, Tsinghua University, Beijing, China
1 shared publication
Latest Publications
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (5) , 4361-4368
A Bio-Inspired Deformable Mouthpart Device With Adaptive Control for Negative Pressure Therapy on Unstructured Limb Surfaces
Negative pressure (NP) therapy is effective in managing chronic lymphedema of the extremities. However, the seal formation of the general head (GH) can fail due to the interspace between the lip and the irregular skin surface on limbs before suction, resulting in the inefficiency of therapy, prolonging the time required for physiotherapy, and increasing the workload of physiotherapists. In this letter, we present a bio-inspired head (BIH) that uses adaptive control for NP therapy on unstructured surfaces. Its lip is designed with soft material inspired by the bloodworm to ensure safe human contact. Additionally, the lip size can be changed with the variation of the cavity pressure, and sensors on the lip could provide contact feedback. An adaptive control method is proposed for autonomous suction on unstructured surfaces. Several experiments were carried out to illustrate the characteristics of this novel head with a deformable lip and contact detection, while the adaptive control method for the NP suction on the unstructured surfaces was validated by phantom and body experiments. Compared with the GH, the results showed that the BIH with adaptive control could automatically fit the irregular arm structures to form a seal and complete the NP suction with a higher success rate(SR).
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (5) , 4361-4368
A Bio-Inspired Deformable Mouthpart Device With Adaptive Control for Negative Pressure Therapy on Unstructured Limb Surfaces
Negative pressure (NP) therapy is effective in managing chronic lymphedema of the extremities. However, the seal formation of the general head (GH) can fail due to the interspace between the lip and the irregular skin surface on limbs before suction, resulting in the inefficiency of therapy, prolonging the time required for physiotherapy, and increasing the workload of physiotherapists. In this letter, we present a bio-inspired head (BIH) that uses adaptive control for NP therapy on unstructured surfaces. Its lip is designed with soft material inspired by the bloodworm to ensure safe human contact. Additionally, the lip size can be changed with the variation of the cavity pressure, and sensors on the lip could provide contact feedback. An adaptive control method is proposed for autonomous suction on unstructured surfaces. Several experiments were carried out to illustrate the characteristics of this novel head with a deformable lip and contact detection, while the adaptive control method for the NP suction on the unstructured surfaces was validated by phantom and body experiments. Compared with the GH, the results showed that the BIH with adaptive control could automatically fit the irregular arm structures to form a seal and complete the NP suction with a higher success rate(SR).
- Open Access
- 5 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (24) , 5305
Tip Estimation Method in Phantoms for Curved Needle Using 2D Transverse Ultrasound Images
Flexible needles have been widely used in minimally invasive surgeries, especially in percutaneous interventions. Among the interventions, tip position of the curved needle is very important, since it directly affects the success of the surgeries. In this paper, we present a method to estimate the tip position of a long-curved needle by using 2D transverse ultrasound images from a robotic ultrasound system. Ultrasound is first used to detect the cross section of long-flexible needle. A new imaging approach is proposed based on the selection of numbers of pixels with a higher gray level, which can directly remove the lower gray level to highlight the needle. After that, the needle shape tracking method is proposed by combining the image processing with the Kalman filter by using 3D needle positions, which develop a robust needle tracking procedure from 1 mm to 8 mm scan intervals. Shape reconstruction is then achieved using the curve fitting method. Finally, the needle tip position is estimated based on the curve fitting result. Experimental results showed that the estimation error of tip position is less than 1 mm within 4 mm scan intervals. The advantage of the proposed method is that the shape and tip position can be estimated through scanning the needle’s cross sections at intervals along the direction of needle insertion without detecting the tip.
- 5 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (24) , 5305
Open AccessTip Estimation Method in Phantoms for Curved Needle Using 2D Transverse Ultrasound Images
Flexible needles have been widely used in minimally invasive surgeries, especially in percutaneous interventions. Among the interventions, tip position of the curved needle is very important, since it directly affects the success of the surgeries. In this paper, we present a method to estimate the tip position of a long-curved needle by using 2D transverse ultrasound images from a robotic ultrasound system. Ultrasound is first used to detect the cross section of long-flexible needle. A new imaging approach is proposed based on the selection of numbers of pixels with a higher gray level, which can directly remove the lower gray level to highlight the needle. After that, the needle shape tracking method is proposed by combining the image processing with the Kalman filter by using 3D needle positions, which develop a robust needle tracking procedure from 1 mm to 8 mm scan intervals. Shape reconstruction is then achieved using the curve fitting method. Finally, the needle tip position is estimated based on the curve fitting result. Experimental results showed that the estimation error of tip position is less than 1 mm within 4 mm scan intervals. The advantage of the proposed method is that the shape and tip position can be estimated through scanning the needle’s cross sections at intervals along the direction of needle insertion without detecting the tip.