Michaela Popková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michaela Popková has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- David Janák
Department of Cardiovascular Surgery, Second Faculty of Medicine, Charles University and University Hospital Motol, Prague, Czech Republic
5 shared publications Mikuláš Mlček
Institute of Physiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
4 shared publicationsHynek Chlup
Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Prague, Czech Republic
2 shared publicationsJ. Kudlička
Charles Univ Prague, Fac Med 1, Dept Physiol, Prague, Czech Republic
2 shared publications- Jan Miroslav Hartinger
Institute of Pharmacology, 1st Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic
2 shared publications - Jan Závora
Clinical Microbiology and ATB Centre, General University Hospital, 128 08 Prague, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 1 February 2021
- Published by Association of Basic Medical Sciences of FBIH in Biomolecules and Biomedicine
- Vol. 21 (1) , 61-70
Vancomycin-releasing cross-linked collagen sponges as wound dressings
The study presents a novel vancomycin-releasing collagen wound dressing derived from Cyprinus carpio collagen type I cross-linked with carbodiimide which retarded the degradation rate and increased the stability of the sponge. Following lyophilization, the dressings were subjected to gamma sterilization. The structure was evaluated via scanning electron microscopy images, micro-computed tomography, and infrared spectrometry. The structural stability and vancomycin release properties were evaluated in phosphate buffered saline. Microbiological testing and a rat model of a wound infected with methicillin-resistant Staphylococcus aureus (MRSA) were then employed to test the efficacy of the treatment of the infected wound. Following an initial mass loss due to the release of vancomycin, the sponges remained stable. After 7 days of exposure in phosphate buffered saline (37°C), 60% of the material remained with a preserved collagen secondary structure together with a high degree of open porosity (over 80%). The analysis of the release of vancomycin revealed homogeneous distribution of the antibiotic both across and between the sponges. The release of vancomycin was retarded as proved by in vitro testing and further confirmed by the animal model from which measurable concentrations were observed in blood samples 24 hours after the subcutaneous implantation of the sponge, which was more than observed following intraperitoneal administration. The sponge was also highly effective in terms of reducing the number of colony-forming units in biopsies extracted from the infected wounds 4 days following the inoculation of the wounds with the MRSA solution. The presented sponges have ideal properties to serve as wound dressing for prevention of surgical site infection or treatment of already infected wounds.
- 1 February 2021
- Published by Association of Basic Medical Sciences of FBIH in Biomolecules and Biomedicine
- Vol. 21 (1) , 61-70
Open AccessVancomycin-releasing cross-linked collagen sponges as wound dressings
The study presents a novel vancomycin-releasing collagen wound dressing derived from Cyprinus carpio collagen type I cross-linked with carbodiimide which retarded the degradation rate and increased the stability of the sponge. Following lyophilization, the dressings were subjected to gamma sterilization. The structure was evaluated via scanning electron microscopy images, micro-computed tomography, and infrared spectrometry. The structural stability and vancomycin release properties were evaluated in phosphate buffered saline. Microbiological testing and a rat model of a wound infected with methicillin-resistant Staphylococcus aureus (MRSA) were then employed to test the efficacy of the treatment of the infected wound. Following an initial mass loss due to the release of vancomycin, the sponges remained stable. After 7 days of exposure in phosphate buffered saline (37°C), 60% of the material remained with a preserved collagen secondary structure together with a high degree of open porosity (over 80%). The analysis of the release of vancomycin revealed homogeneous distribution of the antibiotic both across and between the sponges. The release of vancomycin was retarded as proved by in vitro testing and further confirmed by the animal model from which measurable concentrations were observed in blood samples 24 hours after the subcutaneous implantation of the sponge, which was more than observed following intraperitoneal administration. The sponge was also highly effective in terms of reducing the number of colony-forming units in biopsies extracted from the infected wounds 4 days following the inoculation of the wounds with the MRSA solution. The presented sponges have ideal properties to serve as wound dressing for prevention of surgical site infection or treatment of already infected wounds.
- Open Access
- 13 February 2020
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 18 (1) , 1-12
Increasing venoarterial extracorporeal membrane oxygenation flow puts higher demands on left ventricular work in a porcine model of chronic heart failure
Background: Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in the treatment of circulatory failure, but repeatedly, its negative effects on the left ventricle (LV) have been observed. The purpose of this study is to assess the influence of increasing extracorporeal blood flow (EBF) on LV performance during VA ECMO therapy of decompensated chronic heart failure. Methods: A porcine model of low-output chronic heart failure was developed by long-term fast cardiac pacing. Subsequently, under total anesthesia and artificial ventilation, VA ECMO was introduced to a total of five swine with profound signs of chronic cardiac decompensation. LV performance and organ specific parameters were recorded at different levels of EBF using a pulmonary artery catheter, a pressure–volume loop catheter positioned in the LV, and arterial flow probes on systemic arteries. Results: Tachycardia-induced cardiomyopathy led to decompensated chronic heart failure with mean cardiac output of 2.9 ± 0.4 L/min, severe LV dilation, and systemic hypoperfusion. By increasing the EBF from minimal flow to 5 L/min, we observed a gradual increase of LV peak pressure from 49 ± 15 to 73 ± 11 mmHg (P = 0.001) and an improvement in organ perfusion. On the other hand, cardiac performance parameters revealed higher demands put on LV function: LV end-diastolic pressure increased from 7 ± 2 to 15 ± 3 mmHg, end-diastolic volume increased from 189 ± 26 to 218 ± 30 mL, end-systolic volume increased from 139 ± 17 to 167 ± 15 mL (all P < 0.001), and stroke work increased from 1434 ± 941 to 1892 ± 1036 mmHg*mL (P < 0.05). LV ejection fraction and isovolumetric contractility index did not change significantly. Conclusions: In decompensated chronic heart failure, excessive VA ECMO flow increases demands and has negative effects on the workload of LV. To protect the myocardium from harm, VA ECMO flow should be adjusted with respect to not only systemic perfusion, but also to LV parameters.
- 13 February 2020
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 18 (1) , 1-12
Open AccessIncreasing venoarterial extracorporeal membrane oxygenation flow puts higher demands on left ventricular work in a porcine model of chronic heart failure
Background: Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in the treatment of circulatory failure, but repeatedly, its negative effects on the left ventricle (LV) have been observed. The purpose of this study is to assess the influence of increasing extracorporeal blood flow (EBF) on LV performance during VA ECMO therapy of decompensated chronic heart failure. Methods: A porcine model of low-output chronic heart failure was developed by long-term fast cardiac pacing. Subsequently, under total anesthesia and artificial ventilation, VA ECMO was introduced to a total of five swine with profound signs of chronic cardiac decompensation. LV performance and organ specific parameters were recorded at different levels of EBF using a pulmonary artery catheter, a pressure–volume loop catheter positioned in the LV, and arterial flow probes on systemic arteries. Results: Tachycardia-induced cardiomyopathy led to decompensated chronic heart failure with mean cardiac output of 2.9 ± 0.4 L/min, severe LV dilation, and systemic hypoperfusion. By increasing the EBF from minimal flow to 5 L/min, we observed a gradual increase of LV peak pressure from 49 ± 15 to 73 ± 11 mmHg (P = 0.001) and an improvement in organ perfusion. On the other hand, cardiac performance parameters revealed higher demands put on LV function: LV end-diastolic pressure increased from 7 ± 2 to 15 ± 3 mmHg, end-diastolic volume increased from 189 ± 26 to 218 ± 30 mL, end-systolic volume increased from 139 ± 17 to 167 ± 15 mL (all P < 0.001), and stroke work increased from 1434 ± 941 to 1892 ± 1036 mmHg*mL (P < 0.05). LV ejection fraction and isovolumetric contractility index did not change significantly. Conclusions: In decompensated chronic heart failure, excessive VA ECMO flow increases demands and has negative effects on the workload of LV. To protect the myocardium from harm, VA ECMO flow should be adjusted with respect to not only systemic perfusion, but also to LV parameters.
- 19 March 2019
- Published by SAGE Publications in Journal of Bioactive and Compatible Polymers
- Vol. 34 (3) , 246-262
A novel gentamicin-releasing wound dressing prepared from freshwater fish Cyprinus carpio collagen cross-linked with carbodiimide
Our study presents a novel collagen wound dressing prepared from freshwater fish skin (Cyprinus Carpio) collagen type I. Half of the sponges were cross-linked with carbodiimide. The cross-linked and non-cross-linked collagen sponges were subsequently impregnated with gentamicin and lyophilized thus allowing for the attainment of the appropriate gentamicin content without the removal thereof during the cross-linking stage. The structure was evaluated via micro-CT and infrared spectrometry and the structural stability and gentamicin release properties were evaluated in phosphate buffer solution. The sponges were further tested via a rat model of an infected wound with Pseudomonas aeruginosa inoculation and compared with a reference commercial product. The sponges thus prepared provided a degree of open porosity that was comparable to or higher than that of the reference commercial product. Spectrometry analysis revealed that the cross-linked collagen sponge and reference commercial product sponge preserved their secondary collagen structure after 168 h while early accelerated degradation was observed with respect to the non-cross-linked collagen sponge. Gentamicin was released rapidly from all the sponges. Compared to those animals with gentamicin-containing sponges or gentamicin administered intramuscularly, the animals with the cross-linked collagen sponge without gentamicin exhibited marked clinical and laboratory infection signs. Both the administration routes (intramuscular and via gentamicin-containing sponges) provided similar gentamicin plasma levels. The resulting highly homogeneous product which was characterized by excellent structural and clinical properties proved effective in terms of the treatment of a surgical wound infection in a rat model. We demonstrated that all the gentamicin was released from the sponge and was absorbed in the systemic circulation. This is the first time that Cyprinus Carpio collagen has been used in the preparation of wound dressings. Thus, gentamicin-containing sponges provide a promising tool for the treatment and prevention of surgical site infections.
- 19 March 2019
- Published by SAGE Publications in Journal of Bioactive and Compatible Polymers
- Vol. 34 (3) , 246-262
A novel gentamicin-releasing wound dressing prepared from freshwater fish Cyprinus carpio collagen cross-linked with carbodiimide
Our study presents a novel collagen wound dressing prepared from freshwater fish skin (Cyprinus Carpio) collagen type I. Half of the sponges were cross-linked with carbodiimide. The cross-linked and non-cross-linked collagen sponges were subsequently impregnated with gentamicin and lyophilized thus allowing for the attainment of the appropriate gentamicin content without the removal thereof during the cross-linking stage. The structure was evaluated via micro-CT and infrared spectrometry and the structural stability and gentamicin release properties were evaluated in phosphate buffer solution. The sponges were further tested via a rat model of an infected wound with Pseudomonas aeruginosa inoculation and compared with a reference commercial product. The sponges thus prepared provided a degree of open porosity that was comparable to or higher than that of the reference commercial product. Spectrometry analysis revealed that the cross-linked collagen sponge and reference commercial product sponge preserved their secondary collagen structure after 168 h while early accelerated degradation was observed with respect to the non-cross-linked collagen sponge. Gentamicin was released rapidly from all the sponges. Compared to those animals with gentamicin-containing sponges or gentamicin administered intramuscularly, the animals with the cross-linked collagen sponge without gentamicin exhibited marked clinical and laboratory infection signs. Both the administration routes (intramuscular and via gentamicin-containing sponges) provided similar gentamicin plasma levels. The resulting highly homogeneous product which was characterized by excellent structural and clinical properties proved effective in terms of the treatment of a surgical wound infection in a rat model. We demonstrated that all the gentamicin was released from the sponge and was absorbed in the systemic circulation. This is the first time that Cyprinus Carpio collagen has been used in the preparation of wound dressings. Thus, gentamicin-containing sponges provide a promising tool for the treatment and prevention of surgical site infections.
- 19 December 2018
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 67, S601-S610
Outcome of Resynchronization Therapy on Superficial and Endocardial Electrophysiological Findings
Cardiac resynchronization therapy (CRT) has proven efficacious in the treatment of patients with heart failure and dyssynchronous activation. Currently, we select suitable CRT candidates based on the QRS complex duration (QRSd) and morphology with left bundle branch block being the optimal substrate for resynchronization. To improve CRT response rates, recommendations emphasize attention to electrical parameters both before implant and after it. Therefore, we decided to study activation times before and after CRT on the body surface potential maps (BSPM) and to compare thus obtained results with data from electroanatomical mapping using the CARTO system. Total of 21 CRT recipients with symptomatic heart failure (NYHA II-IV), sinus rhythm, and QRSd ≥150 ms and 7 healthy controls were studied. The maximum QRSd and the longest and shortest activation times (ATmax and ATmin) were set in the BSPM maps and their locations on the chest were compared with CARTO derived time interval and site of the latest (LATmax) and earliest (LATmin) ventricular activation. In CRT patients, all these parameters were measured during both spontaneous rhythm and biventricular pacing (BVP) and compared with the findings during the spontaneous sinus rhythm in the healthy controls. QRSd was 169.7±12.1 ms during spontaneous rhythm in the CRT group and 104.3±10.2 ms after CRT (p
- 19 December 2018
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 67, S601-S610
Outcome of Resynchronization Therapy on Superficial and Endocardial Electrophysiological Findings
Cardiac resynchronization therapy (CRT) has proven efficacious in the treatment of patients with heart failure and dyssynchronous activation. Currently, we select suitable CRT candidates based on the QRS complex duration (QRSd) and morphology with left bundle branch block being the optimal substrate for resynchronization. To improve CRT response rates, recommendations emphasize attention to electrical parameters both before implant and after it. Therefore, we decided to study activation times before and after CRT on the body surface potential maps (BSPM) and to compare thus obtained results with data from electroanatomical mapping using the CARTO system. Total of 21 CRT recipients with symptomatic heart failure (NYHA II-IV), sinus rhythm, and QRSd ≥150 ms and 7 healthy controls were studied. The maximum QRSd and the longest and shortest activation times (ATmax and ATmin) were set in the BSPM maps and their locations on the chest were compared with CARTO derived time interval and site of the latest (LATmax) and earliest (LATmin) ventricular activation. In CRT patients, all these parameters were measured during both spontaneous rhythm and biventricular pacing (BVP) and compared with the findings during the spontaneous sinus rhythm in the healthy controls. QRSd was 169.7±12.1 ms during spontaneous rhythm in the CRT group and 104.3±10.2 ms after CRT (p
- 12 August 2018
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 67 (4) , 555-562
Severe Acute Heart Failure – Experimental Model With Very Low Mortality
The growth in the experimental research of facilities to support extracorporeal circulation requires the further development of models of acute heart failure that can be well controlled and reproduced. Two types of acute heart failure were examined in domestic pigs (Sus scrofa domestica): a hypoxic model (n=5) with continuous perfusion of the left coronary artery by hypoxic deoxygenated blood and ischemic model (n=9) with proximal closure of the left coronary artery and controlled hypoperfusion behind the closure. The aim was a severe, stable heart pump failure defined by hemodynamic parameters changes: a) decrease in cardiac output by at least 50 %; b) decrease in mixed venous blood saturation to under 60 %; c) left ventricular ejection fraction below 25 %; and d) decrease in flow via the carotid arteries at least 50 %. Acute heart failure developed in the first group in one animal with no acute mortality and in the second group in 8 animals with no acute mortality. In the case of ischemic model the cardiac output fell from 6.70±0.89 l/min to 2.89±0.75 l/min. The saturation of the mixed venous blood decreased from 83±2 % to 58±8 %. The left ventricular ejection fraction decreased from 50±8 % to 19±2 %. The flow via the carotid arteries decreased from 337±78 ml/min to 136±59 ml/min (P≤0.001 for all comparisons). The proposed ischemic model is not burdened with acute mortality in the development of heart failure and is suitable for further use in experimental research into extracorporeal circulatory support.
- 12 August 2018
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 67 (4) , 555-562
Severe Acute Heart Failure – Experimental Model With Very Low Mortality
The growth in the experimental research of facilities to support extracorporeal circulation requires the further development of models of acute heart failure that can be well controlled and reproduced. Two types of acute heart failure were examined in domestic pigs (Sus scrofa domestica): a hypoxic model (n=5) with continuous perfusion of the left coronary artery by hypoxic deoxygenated blood and ischemic model (n=9) with proximal closure of the left coronary artery and controlled hypoperfusion behind the closure. The aim was a severe, stable heart pump failure defined by hemodynamic parameters changes: a) decrease in cardiac output by at least 50 %; b) decrease in mixed venous blood saturation to under 60 %; c) left ventricular ejection fraction below 25 %; and d) decrease in flow via the carotid arteries at least 50 %. Acute heart failure developed in the first group in one animal with no acute mortality and in the second group in 8 animals with no acute mortality. In the case of ischemic model the cardiac output fell from 6.70±0.89 l/min to 2.89±0.75 l/min. The saturation of the mixed venous blood decreased from 83±2 % to 58±8 %. The left ventricular ejection fraction decreased from 50±8 % to 19±2 %. The flow via the carotid arteries decreased from 337±78 ml/min to 136±59 ml/min (P≤0.001 for all comparisons). The proposed ischemic model is not burdened with acute mortality in the development of heart failure and is suitable for further use in experimental research into extracorporeal circulatory support.
- 17 February 2018
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 132,p. e57030
Tachycardia-Induced Cardiomyopathy As a Chronic Heart Failure Model in Swine
A stable and reliable model of chronic heart failure is required for many experiments to understand hemodynamics or to test effects of new treatment methods. Here, we present such a model by tachycardia-induced cardiomyopathy, which can be produced by rapid cardiac pacing in swine. A single pacing lead is introduced transvenously into fully anaesthetized healthy swine, to the apex of the right ventricle, and fixated. Its other end is then tunneled dorsally to the paravertebral region. There, it is connected to an in-house modified heart pacemaker unit that is then implanted in a subcutaneous pocket. After 4 - 8 weeks of rapid ventricular pacing at rates of 200 - 240 beats/min, physical examination revealed signs of severe heart failure - tachypnea, spontaneous sinus tachycardia, and fatigue. Echocardiography and X-ray showed dilation of all heart chambers, effusions, and severe systolic dysfunction. These findings correspond well to decompensated dilated cardiomyopathy and are also preserved after the cessation of pacing. This model of tachycardia-induced cardiomyopathy can be used for studying the pathophysiology of progressive chronic heart failure, especially hemodynamic changes caused by new treatment modalities like mechanical circulatory supports. This methodology is easy to perform and the results are robust and reproducible.
- 17 February 2018
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 132,p. e57030
Tachycardia-Induced Cardiomyopathy As a Chronic Heart Failure Model in Swine
A stable and reliable model of chronic heart failure is required for many experiments to understand hemodynamics or to test effects of new treatment methods. Here, we present such a model by tachycardia-induced cardiomyopathy, which can be produced by rapid cardiac pacing in swine. A single pacing lead is introduced transvenously into fully anaesthetized healthy swine, to the apex of the right ventricle, and fixated. Its other end is then tunneled dorsally to the paravertebral region. There, it is connected to an in-house modified heart pacemaker unit that is then implanted in a subcutaneous pocket. After 4 - 8 weeks of rapid ventricular pacing at rates of 200 - 240 beats/min, physical examination revealed signs of severe heart failure - tachypnea, spontaneous sinus tachycardia, and fatigue. Echocardiography and X-ray showed dilation of all heart chambers, effusions, and severe systolic dysfunction. These findings correspond well to decompensated dilated cardiomyopathy and are also preserved after the cessation of pacing. This model of tachycardia-induced cardiomyopathy can be used for studying the pathophysiology of progressive chronic heart failure, especially hemodynamic changes caused by new treatment modalities like mechanical circulatory supports. This methodology is easy to perform and the results are robust and reproducible.
- 14 December 2017
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 66, S529-S536
Detection of Microembolic Signals in the Common Carotid Artery Using Doppler Sonography in the Porcine Model of Acute Heart Failure Treated by Veno-Arterial Extracorporeal Membrane Oxygenation
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.
- 14 December 2017
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 66, S529-S536
Detection of Microembolic Signals in the Common Carotid Artery Using Doppler Sonography in the Porcine Model of Acute Heart Failure Treated by Veno-Arterial Extracorporeal Membrane Oxygenation
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.
- 17 December 2016
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 65, S621-S631
Regional Tissue Oximetry Reflects Changes in Arterial Flow in Porcine Chronic Heart Failure Treated With Venoarterial Extracorporeal Membrane Oxygenation
Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in treatment of decompensated heart failure. Our aim was to investigate its effects on regional perfusion and tissue oxygenation with respect to extracorporeal blood flow (EBF). In five swine, decompensated low-output chronic heart failure was induced by long-term rapid ventricular pacing. Subsequently, VA ECMO was introduced and left ventricular (LV) volume, aortic blood pressure, regional arterial flow and tissue oxygenation were continuously recorded at different levels of EBF. With increasing EBF from minimal to 5 l/min, mean arterial pressure increased from 47±22 to 84±12 mm Hg (P<0.001) and arterial blood flow increased in carotid artery from 211±72 to 479±58 ml/min (P<0.01) and in subclavian artery from 103±49 to 296±54 ml/min (P<0.001). Corresponding brain and brachial tissue oxygenation increased promptly from 57±6 to 74±3 % and from 37±6 to 77±6 %, respectively (both P<0.01). Presented results confirm that VA ECMO is a capable form of heart support. Regional arterial flow and tissue oxygenation suggest that partial circulatory support may be sufficient to supply brain and peripheral tissue by oxygen.
- 17 December 2016
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 65, S621-S631
Regional Tissue Oximetry Reflects Changes in Arterial Flow in Porcine Chronic Heart Failure Treated With Venoarterial Extracorporeal Membrane Oxygenation
Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in treatment of decompensated heart failure. Our aim was to investigate its effects on regional perfusion and tissue oxygenation with respect to extracorporeal blood flow (EBF). In five swine, decompensated low-output chronic heart failure was induced by long-term rapid ventricular pacing. Subsequently, VA ECMO was introduced and left ventricular (LV) volume, aortic blood pressure, regional arterial flow and tissue oxygenation were continuously recorded at different levels of EBF. With increasing EBF from minimal to 5 l/min, mean arterial pressure increased from 47±22 to 84±12 mm Hg (P<0.001) and arterial blood flow increased in carotid artery from 211±72 to 479±58 ml/min (P<0.01) and in subclavian artery from 103±49 to 296±54 ml/min (P<0.001). Corresponding brain and brachial tissue oxygenation increased promptly from 57±6 to 74±3 % and from 37±6 to 77±6 %, respectively (both P<0.01). Presented results confirm that VA ECMO is a capable form of heart support. Regional arterial flow and tissue oxygenation suggest that partial circulatory support may be sufficient to supply brain and peripheral tissue by oxygen.