Niklas Magnusson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Niklas Magnusson has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Magne Runde
SINTEF Energy Research
8 shared publications - Arne Nysveen
Norwegian University of Science and Technology
3 shared publications A.B. Abrahamsen
2 shared publications- Adela Marian
Research Institute for Sustainability, Potsdam, Germany
2 shared publications - Antonio Morandi
University of Bologna
2 shared publications - Christian-Eric Bruzek
ASG Superconductors, Genoa, Italy
2 shared publications
Latest Publications
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
MgB2-Based MVDC Superconducting Power Cable in Liquid Hydrogen for Hybrid Energy Distribution
The combination of liquid hydrogen and superconducting cables presents a unique opportunity to distribute both hydrogen and bulk electricity in the same infrastructure. In particular, liquid hydrogen around 20 K is ideally suited for cooling the MgB 2 superconductor, resulting in a compact power cable that also leaves sufficient place for the hydrogen flow. Such a hybrid system operating in the MVDC range at 25 kV and 20 kA constitutes one of the main goals of the European project SCARLET. After a description of the rationale and benefits of the electricity – hydrogen system, various possible applications and a first distribution system are presented. Furthermore, the different cable components already designed are discussed along with the research challenges and general strategy for the development.
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
MgB2-Based MVDC Superconducting Power Cable in Liquid Hydrogen for Hybrid Energy Distribution
The combination of liquid hydrogen and superconducting cables presents a unique opportunity to distribute both hydrogen and bulk electricity in the same infrastructure. In particular, liquid hydrogen around 20 K is ideally suited for cooling the MgB 2 superconductor, resulting in a compact power cable that also leaves sufficient place for the hydrogen flow. Such a hybrid system operating in the MVDC range at 25 kV and 20 kA constitutes one of the main goals of the European project SCARLET. After a description of the rationale and benefits of the electricity – hydrogen system, various possible applications and a first distribution system are presented. Furthermore, the different cable components already designed are discussed along with the research challenges and general strategy for the development.
- 8 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
SCARLET – A European Effort to Develop HTS and MgB2 Based MVDC Cables
Superconducting cables have been proven in a variety of pilot projects and utility installations, demonstrating several of their advantages, including compact size and low energy losses, which can make the technology economically attractive for certain applications. It is clear though that different applications impose different requirements and challenges, but also opportunities for the cables. An interesting application is high-power DC transfer at medium voltage (MVDC). The high-current capability of the superconductor allows for a reduction in voltage while maintaining or increasing the power transfer level. In this way, one MVDC superconducting cable can replace one or more conventional high-voltage DC cables. In the European project Superconducting cables for sustainable energy transition (SCARLET), two types of MVDC cables will be developed, one based on HTS and one on MgB 2 materials. Additionally, protection requirements will be considered, including the development of a modular DC fault current limiter for 10 kA. A main motivation for the development is the elimination of costly high-voltage converter stations when going from high to medium voltage, e.g., for offshore wind power plants. Another feature is the combined hydrogen and electricity transmission from generation sites to industry or mobility end users. This paper describes the superconducting MVDC cable concept as well as the main challenges and research needed to develop and type test the cables.
- 8 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
SCARLET – A European Effort to Develop HTS and MgB2 Based MVDC Cables
Superconducting cables have been proven in a variety of pilot projects and utility installations, demonstrating several of their advantages, including compact size and low energy losses, which can make the technology economically attractive for certain applications. It is clear though that different applications impose different requirements and challenges, but also opportunities for the cables. An interesting application is high-power DC transfer at medium voltage (MVDC). The high-current capability of the superconductor allows for a reduction in voltage while maintaining or increasing the power transfer level. In this way, one MVDC superconducting cable can replace one or more conventional high-voltage DC cables. In the European project Superconducting cables for sustainable energy transition (SCARLET), two types of MVDC cables will be developed, one based on HTS and one on MgB 2 materials. Additionally, protection requirements will be considered, including the development of a modular DC fault current limiter for 10 kA. A main motivation for the development is the elimination of costly high-voltage converter stations when going from high to medium voltage, e.g., for offshore wind power plants. Another feature is the combined hydrogen and electricity transmission from generation sites to industry or mobility end users. This paper describes the superconducting MVDC cable concept as well as the main challenges and research needed to develop and type test the cables.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 11 (1) , 73-82
How to Plug In the Fishing Fleet: Connectors in charging infrastructure for small fishing boats
Fishing fleets are targeted for electrification in many parts of the world. These vessels represent a large potential for emission reductions by transitioning from fossil to hybrid and electric propulsion. However, a massive electrification of such vessels requires a disruptive green shift, introducing safe and reliable battery charging infrastructure along the coastline. Up to now, electric energy has been supplied only, if supplied at all, for auxiliary loads, such as lighting, heating, and ventilation, when fishing boats are in a harbor. The standard connection method has been through industrial connectors. In other sectors, such as automotive, other connector types are used. When batteries are installed on fishing vessels, high charging powers and currents are deployed, calling for robust connector solutions.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 11 (1) , 73-82
How to Plug In the Fishing Fleet: Connectors in charging infrastructure for small fishing boats
Fishing fleets are targeted for electrification in many parts of the world. These vessels represent a large potential for emission reductions by transitioning from fossil to hybrid and electric propulsion. However, a massive electrification of such vessels requires a disruptive green shift, introducing safe and reliable battery charging infrastructure along the coastline. Up to now, electric energy has been supplied only, if supplied at all, for auxiliary loads, such as lighting, heating, and ventilation, when fishing boats are in a harbor. The standard connection method has been through industrial connectors. In other sectors, such as automotive, other connector types are used. When batteries are installed on fishing vessels, high charging powers and currents are deployed, calling for robust connector solutions.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 9 (1) , 1060-1071
Reliability of Bolted Aluminum Busbars for Battery Systems: Effect of Nickel Coating and Corrosive Environment
Bolted busbar connections are a simple and versatile connection method used in battery systems. Copper busbars are widely used for such bolted connections; however, aluminum offers the potential to save weight and cost. To date, the reliability of aluminum connections dimensioned for battery systems and the vulnerability to corrosion accelerants is not established. In this study, bolted aluminum connections were tested under operational and environmental conditions applicable to battery systems. Four bolted configurations (AA1070 and AA6101, with nickel plating or brushed contact surfaces) were exposed to corrosive environments and current-induced thermal cycling. Nickel plating provided a robust contact interface that maintained stable resistance over 6000 cycles across three temperature levels. The nickel plating’s electrical performance was unaffected by the corrosive environments, including humidity, salt mist, and hydrogen sulfide exposure. The brushed aluminum configurations produced connections with greater contact resistance variation and achieving a joint performance factor < 1.5 was critical for long-term reliability. The growing appeal of aluminum in battery systems requires verification methods capable of assessing new contact configurations. Currently, corrosion test environments for evaluating aluminum contacts are lacking in the literature. This study provides insights into the performance of bolted aluminum configurations dimensioned for battery systems and provides methodology for accelerated verification of new configurations.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 9 (1) , 1060-1071
Reliability of Bolted Aluminum Busbars for Battery Systems: Effect of Nickel Coating and Corrosive Environment
Bolted busbar connections are a simple and versatile connection method used in battery systems. Copper busbars are widely used for such bolted connections; however, aluminum offers the potential to save weight and cost. To date, the reliability of aluminum connections dimensioned for battery systems and the vulnerability to corrosion accelerants is not established. In this study, bolted aluminum connections were tested under operational and environmental conditions applicable to battery systems. Four bolted configurations (AA1070 and AA6101, with nickel plating or brushed contact surfaces) were exposed to corrosive environments and current-induced thermal cycling. Nickel plating provided a robust contact interface that maintained stable resistance over 6000 cycles across three temperature levels. The nickel plating’s electrical performance was unaffected by the corrosive environments, including humidity, salt mist, and hydrogen sulfide exposure. The brushed aluminum configurations produced connections with greater contact resistance variation and achieving a joint performance factor < 1.5 was critical for long-term reliability. The growing appeal of aluminum in battery systems requires verification methods capable of assessing new contact configurations. Currently, corrosion test environments for evaluating aluminum contacts are lacking in the literature. This study provides insights into the performance of bolted aluminum configurations dimensioned for battery systems and provides methodology for accelerated verification of new configurations.
- 9 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (3) , 1135-1142
Modeling of Internal Pressure Dynamics in Mass-Impregnated Nondraining HVDC Cables
Changing the current loading of mass-impregnated non-draining power cables causes the pressure in the insulation to vary over a wide range. It is generally recognized that under certain conditions—typically after a large load reduction—the pressure becomes so low that shrinkage cavities (voids) form in the insulation, and that partial discharges that may damage the insulation ignite. A finite element model for temperature, electric field and pressure dynamics throughout the insulation layer has been developed. Comparisons with previously obtained measurements on full-scale HVDC subsea cable samples subjected to a variety of loading patterns, external pressures (sea depths) and ambient temperatures, show that the model replicates the pressure behavior of the insulation reasonably well. Most importantly, the complicated viscoelastic properties of the lead sheath, which have a profound effect on the internal pressure dynamics and thereby on the prospects of forming potentially harmful cavities, appear to be sufficiently accurately modelled.
- 9 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (3) , 1135-1142
Modeling of Internal Pressure Dynamics in Mass-Impregnated Nondraining HVDC Cables
Changing the current loading of mass-impregnated non-draining power cables causes the pressure in the insulation to vary over a wide range. It is generally recognized that under certain conditions—typically after a large load reduction—the pressure becomes so low that shrinkage cavities (voids) form in the insulation, and that partial discharges that may damage the insulation ignite. A finite element model for temperature, electric field and pressure dynamics throughout the insulation layer has been developed. Comparisons with previously obtained measurements on full-scale HVDC subsea cable samples subjected to a variety of loading patterns, external pressures (sea depths) and ambient temperatures, show that the model replicates the pressure behavior of the insulation reasonably well. Most importantly, the complicated viscoelastic properties of the lead sheath, which have a profound effect on the internal pressure dynamics and thereby on the prospects of forming potentially harmful cavities, appear to be sufficiently accurately modelled.
- Open Access
- 1 August 2021
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 587
Testing of an MgB2 coil for a wind turbine generator pole
- 1 August 2021
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 587
Open AccessTesting of an MgB2 coil for a wind turbine generator pole
- Open Access
- 30 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (6) , 1-4
Eddy Current Loss in Grain-Oriented Steel Laminations Due to Normal Leakage Flux
Leakage flux penetrating laminated iron cores in power transformers and large generators induces eddy current and local loss. Due to the strong magnetic anisotropy of the lamination structure, the penetrating flux tends to saturate the lamination in its plane, even when the incident stray flux density is low. Therefore, the combined effect of anisotropy and nonlinearity has a great impact on the eddy current distribution and the associated power losses. Moreover, the incident normal flux often interacts with the main flux, where the phase angle between the two fluxes may play a significant role. A measurement device is developed to emulate the actual leakage flux in a steel lamination and the power losses are measured at the flux densities of various magnitudes and phases. The measurement results are compared and interpreted by the results obtained from a finite-element analysis, where the homogenization approach for material modeling is implemented, taking the combined effect of magnetic anisotropy and the saturation into account.
- 30 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (6) , 1-4
Open AccessEddy Current Loss in Grain-Oriented Steel Laminations Due to Normal Leakage Flux
Leakage flux penetrating laminated iron cores in power transformers and large generators induces eddy current and local loss. Due to the strong magnetic anisotropy of the lamination structure, the penetrating flux tends to saturate the lamination in its plane, even when the incident stray flux density is low. Therefore, the combined effect of anisotropy and nonlinearity has a great impact on the eddy current distribution and the associated power losses. Moreover, the incident normal flux often interacts with the main flux, where the phase angle between the two fluxes may play a significant role. A measurement device is developed to emulate the actual leakage flux in a steel lamination and the power losses are measured at the flux densities of various magnitudes and phases. The measurement results are compared and interpreted by the results obtained from a finite-element analysis, where the homogenization approach for material modeling is implemented, taking the combined effect of magnetic anisotropy and the saturation into account.
- 1 August 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (8) , 084705
Apparatus for loss measurements under multidirectional and dc-bias flux in electrical steel laminations
Conventional standardized power loss measurements for electric steels are performed at flux densities with a single sinusoidal and unidirectional excitation. However, the flux inside electrical steel laminations can deviate significantly from the standard condition, and the loss is sensitive to such deviations of the flux in time and space. In this article, we describe the design and construction of an apparatus for loss measurements under two scenarios: (1) The main flux in the rolling direction is superimposed with flux in either the transverse or normal direction, while varying magnitude and phase angle between two fluxes and (2) the main flux having a dc-bias. The main flux in the rolling direction is generated in a square lamination frame by the current in excitation coils. The transverse and normal direction fluxes are generated by the current in auxiliary excitation coils wound around powder cores. The dc-bias flux is created either by an ac current with a small dc offset in the excitation coils or by a separate coil excited by a dc current. We implement and compare the two dc-bias methods and discuss the commons and differences. Finally, we present experimental results showing the possibilities for loss measurements under the combined action of magnetic flux in different directions and under dc-bias.
- 1 August 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (8) , 084705
Apparatus for loss measurements under multidirectional and dc-bias flux in electrical steel laminations
Conventional standardized power loss measurements for electric steels are performed at flux densities with a single sinusoidal and unidirectional excitation. However, the flux inside electrical steel laminations can deviate significantly from the standard condition, and the loss is sensitive to such deviations of the flux in time and space. In this article, we describe the design and construction of an apparatus for loss measurements under two scenarios: (1) The main flux in the rolling direction is superimposed with flux in either the transverse or normal direction, while varying magnitude and phase angle between two fluxes and (2) the main flux having a dc-bias. The main flux in the rolling direction is generated in a square lamination frame by the current in excitation coils. The transverse and normal direction fluxes are generated by the current in auxiliary excitation coils wound around powder cores. The dc-bias flux is created either by an ac current with a small dc offset in the excitation coils or by a separate coil excited by a dc current. We implement and compare the two dc-bias methods and discuss the commons and differences. Finally, we present experimental results showing the possibilities for loss measurements under the combined action of magnetic flux in different directions and under dc-bias.
- Open Access
- 1 November 2014
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 506, 133-137
Hysteresis losses in MgB 2 superconductors exposed to combinations of low AC and high DC magnetic fields and transport currents
- 1 November 2014
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 506, 133-137
Open AccessHysteresis losses in MgB 2 superconductors exposed to combinations of low AC and high DC magnetic fields and transport currents