Tosiaki Miyati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tosiaki Miyati has a total of 262 co-authors. Here are the top co-authors by number of shared publications:
- Yasuo Takatsu
Graduate School of Medical Sciences, Fujita Health University, Toyoake, Japan
27 shared publications Naoki Ohno
Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan
17 shared publications- Naoki Ohno
Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences Kanazawa University Kanazawa Japan
15 shared publications - Satoshi Kobayashi
Department of Radiology, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan
13 shared publications - Masafumi Nakamura
Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan; Department of Radiological Technology, Faculty of Health and Welfare, Tokushima Bunri University, 1314-1 Shido, Sanuki, Kagawa 769-2193, Japan
10 shared publications Toshifumi Gabata
Graduate School of Medical Sciences Kanazawa University Kanazawa Japan
9 shared publications
Latest Publications
- Open Access
- 10 August 2026
- Published by Scientific Scholar in Journal of Clinical Imaging Science
- Vol. 16, 30
Comparative evaluation of zoomed and parallel diffusion-weighted imaging: A phantom study
Objectives: Single-shot echo-planar imaging sequences with parallel imaging are widely used for diffusion-weighted imaging (DWI). However, when small fields of view and higher phase-encoding reduction ratios (PRs) are applied, image quality may deteriorate because of imperfections in the unfolding process of parallel imaging. Previous studies have suggested that Zoomed DWI (Zoom-DWI) may address this limitation. Therefore, we compared Zoom-DWI with parallel DWI (Parallel-DWI) across different PRs to evaluate image quality. Material and Methods: Zoom-DWI and Parallel-DWI were performed using identical acquisition times and imaging parameters at different PRs. Signal-to-noise ratio (SNR), image uniformity, slice thickness, spatial resolution, and image distortion were evaluated. Results: At a PR of 66.6%, the SNR of Zoom-DWI was approximately 1.4–3.3-fold higher than that of Parallel-DWI at the image center, where reconstruction errors in parallel imaging become more pronounced as PR increases. Image uniformity was also higher in Zoom-DWI than in Parallel-DWI, and the difference increased by approximately 41.0% at a PR of 66.6%. Slice thickness, spatial resolution, and image distortion were comparable between the two methods. Conclusion: In this phantom study, Zoom-DWI demonstrated higher SNR and greater image uniformity than Parallel-DWI, particularly at higher PRs and in the central image region.
- 10 August 2026
- Published by Scientific Scholar in Journal of Clinical Imaging Science
- Vol. 16, 30
Open AccessComparative evaluation of zoomed and parallel diffusion-weighted imaging: A phantom study
Objectives: Single-shot echo-planar imaging sequences with parallel imaging are widely used for diffusion-weighted imaging (DWI). However, when small fields of view and higher phase-encoding reduction ratios (PRs) are applied, image quality may deteriorate because of imperfections in the unfolding process of parallel imaging. Previous studies have suggested that Zoomed DWI (Zoom-DWI) may address this limitation. Therefore, we compared Zoom-DWI with parallel DWI (Parallel-DWI) across different PRs to evaluate image quality. Material and Methods: Zoom-DWI and Parallel-DWI were performed using identical acquisition times and imaging parameters at different PRs. Signal-to-noise ratio (SNR), image uniformity, slice thickness, spatial resolution, and image distortion were evaluated. Results: At a PR of 66.6%, the SNR of Zoom-DWI was approximately 1.4–3.3-fold higher than that of Parallel-DWI at the image center, where reconstruction errors in parallel imaging become more pronounced as PR increases. Image uniformity was also higher in Zoom-DWI than in Parallel-DWI, and the difference increased by approximately 41.0% at a PR of 66.6%. Slice thickness, spatial resolution, and image distortion were comparable between the two methods. Conclusion: In this phantom study, Zoom-DWI demonstrated higher SNR and greater image uniformity than Parallel-DWI, particularly at higher PRs and in the central image region.
- 29 July 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (3) , 1579-1594
Evaluation of generative adversarial network-based postprocessing super-resolution for lumbar spine magnetic resonance imaging
- 29 July 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (3) , 1579-1594
Evaluation of generative adversarial network-based postprocessing super-resolution for lumbar spine magnetic resonance imaging
- 6 July 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (3) , 1413-1420
Multiparametric analysis using MRI after preoperative embolization in meningioma: a preliminary study
Quantitative evaluation of early perfusion and diffusion changes in meningiomas, including both intratumoral region and peritumoral edema, remains limited within the first 1–2 days postembolization. This study aimed to use multiparametric magnetic resonance imaging (MRI) to investigate early structural and perfusion-related changes in both the intratumoral region and peritumoral edema after preoperative embolization of supratentorial meningiomas. Seven patients with supratentorial meningiomas underwent MRI before and 1–2 days after embolization with Embosphere microspheres (100–300 μm and 300–500 μm), primarily via the middle meningeal artery. Quantitative assessments included intratumoral region and peritumoral edema volumes, quantitative T2, and intravoxel incoherent motion (IVIM) parameters (D, f, D*, fD*, and ΔD). In the intratumoral region, significant reductions in volume (mean change of 28.1%, P = 0.028), quantitative T2 (mean change of 7.4%, P = 0.028), and all perfusion-related IVIM parameters (f, D*, fD*) (P ≤ 0.043) were observed. These findings are consistent with early postembolization ischemia. In contrast, the true diffusion coefficient (D) and the dynamic parameter (ΔD) showed no significant change (P > 0.05). Peritumoral edema showed no significant differences across the measured parameters (P > 0.05). Preoperative embolization is associated with early reductions in viable tumor volume, perfusion-related IVIM parameters, and T2, reflecting imaging changes consistent with early ischemia primarily within the intratumoral region. The stability of peritumoral edema parameters suggests that early postembolization effects are mainly limited to the intratumoral region.
- 6 July 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (3) , 1413-1420
Multiparametric analysis using MRI after preoperative embolization in meningioma: a preliminary study
Quantitative evaluation of early perfusion and diffusion changes in meningiomas, including both intratumoral region and peritumoral edema, remains limited within the first 1–2 days postembolization. This study aimed to use multiparametric magnetic resonance imaging (MRI) to investigate early structural and perfusion-related changes in both the intratumoral region and peritumoral edema after preoperative embolization of supratentorial meningiomas. Seven patients with supratentorial meningiomas underwent MRI before and 1–2 days after embolization with Embosphere microspheres (100–300 μm and 300–500 μm), primarily via the middle meningeal artery. Quantitative assessments included intratumoral region and peritumoral edema volumes, quantitative T2, and intravoxel incoherent motion (IVIM) parameters (D, f, D*, fD*, and ΔD). In the intratumoral region, significant reductions in volume (mean change of 28.1%, P = 0.028), quantitative T2 (mean change of 7.4%, P = 0.028), and all perfusion-related IVIM parameters (f, D*, fD*) (P ≤ 0.043) were observed. These findings are consistent with early postembolization ischemia. In contrast, the true diffusion coefficient (D) and the dynamic parameter (ΔD) showed no significant change (P > 0.05). Peritumoral edema showed no significant differences across the measured parameters (P > 0.05). Preoperative embolization is associated with early reductions in viable tumor volume, perfusion-related IVIM parameters, and T2, reflecting imaging changes consistent with early ischemia primarily within the intratumoral region. The stability of peritumoral edema parameters suggests that early postembolization effects are mainly limited to the intratumoral region.
- 10 June 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 133, 110728
Neurofluid fluctuation analysis using dynamical network biomarker MRI in idiopathic normal pressure hydrocephalus
- 10 June 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 133, 110728
Neurofluid fluctuation analysis using dynamical network biomarker MRI in idiopathic normal pressure hydrocephalus
- 6 June 2026
- Published by Elsevier in Clinical Radiology
- Vol. 99, 107405
Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography
- 6 June 2026
- Published by Elsevier in Clinical Radiology
- Vol. 99, 107405
Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography
- Open Access
- 2 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 238-246
Motion‐Compensated Diffusion Imaging With Phase‐Contrast for Robust Quantification of Regional Cerebral Blood Flow
Purpose: To develop and evaluate a motion‐compensated diffusion imaging with phase‐contrast (MC‐DIP) technique for mitigating errors in regional cerebral blood flow (rCBF) quantification caused by physiological brain motion. Methods: Diffusion‐weighted images were acquired in 11 healthy volunteers on a 3.0 T MRI system using three gradient schemes: second‐order motion‐compensated (2nd‐MC), first‐order motion‐compensated (1st‐MC), and non‐compensated (non‐MC) diffusion gradients. Absolute rCBF maps were generated for each scheme by calibrating intravoxel incoherent motion‐derived relative perfusion maps with total cerebral blood flow measured by phase‐contrast MRI. The rCBF values from the DIP methods were compared in gray and white matter with a reference arterial spin labeling (ASL) measurement. Results: Both motion‐compensated schemes (2nd‐MC and 1st‐MC) provided significantly better biexponential fitting accuracy in gray matter compared with the non‐MC scheme ( p < 0.05). In white matter, however, only the 2nd‐MC scheme resulted in a significant improvement over the other methods ( p < 0.05). While rCBF values from all three DIP methods showed a strong positive correlation with ASL in gray matter ( ρ ≥ 0.82, p < 0.05), only the 2nd‐MC‐DIP method demonstrated a significant positive correlation in white matter ( ρ = 0.69, p < 0.05). Conclusion: The implementation of second‐order motion compensation within the DIP framework improves fitting accuracy, enabling robust rCBF quantification.
- 2 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 238-246
Open AccessMotion‐Compensated Diffusion Imaging With Phase‐Contrast for Robust Quantification of Regional Cerebral Blood Flow
Purpose: To develop and evaluate a motion‐compensated diffusion imaging with phase‐contrast (MC‐DIP) technique for mitigating errors in regional cerebral blood flow (rCBF) quantification caused by physiological brain motion. Methods: Diffusion‐weighted images were acquired in 11 healthy volunteers on a 3.0 T MRI system using three gradient schemes: second‐order motion‐compensated (2nd‐MC), first‐order motion‐compensated (1st‐MC), and non‐compensated (non‐MC) diffusion gradients. Absolute rCBF maps were generated for each scheme by calibrating intravoxel incoherent motion‐derived relative perfusion maps with total cerebral blood flow measured by phase‐contrast MRI. The rCBF values from the DIP methods were compared in gray and white matter with a reference arterial spin labeling (ASL) measurement. Results: Both motion‐compensated schemes (2nd‐MC and 1st‐MC) provided significantly better biexponential fitting accuracy in gray matter compared with the non‐MC scheme ( p < 0.05). In white matter, however, only the 2nd‐MC scheme resulted in a significant improvement over the other methods ( p < 0.05). While rCBF values from all three DIP methods showed a strong positive correlation with ASL in gray matter ( ρ ≥ 0.82, p < 0.05), only the 2nd‐MC‐DIP method demonstrated a significant positive correlation in white matter ( ρ = 0.69, p < 0.05). Conclusion: The implementation of second‐order motion compensation within the DIP framework improves fitting accuracy, enabling robust rCBF quantification.
- 5 September 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1267-1282
Classification of liver lesions based on temporal changes in hepatobiliary phase contrast on magnetic resonance imaging: a preliminary study
This study evaluated whether temporal changes from the dynamic late phase to the hepatobiliary phase using gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid supported liver tumor classification. A total of 147 patients with 165 lesions (hepatocellular carcinoma [HCC], metastases, and hemangiomas) underwent 3.0 T MRI. Quantitative liver lesion contrast (Q-LLC) and its rate of change (%) at 3, 10, and 15 min postcontrast were analyzed. Tumors were stratified according to albumin–bilirubin (ALBI) grade. For ALBI grade 1, the Q-LLC significantly differed at 3 min and 10 min (P < 0.05). Q-LLC increased over time, and the rate of change was the lowest in HCC, followed by metastases, and was the highest in hemangiomas. Significant differences in the rate of change were observed among tumor types for ALBI grade 1 (P < 0.01). These findings suggest that the Q-LLC rate of change may aid in liver tumor classification, particularly in patients with preserved liver function.
- 5 September 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1267-1282
Classification of liver lesions based on temporal changes in hepatobiliary phase contrast on magnetic resonance imaging: a preliminary study
This study evaluated whether temporal changes from the dynamic late phase to the hepatobiliary phase using gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid supported liver tumor classification. A total of 147 patients with 165 lesions (hepatocellular carcinoma [HCC], metastases, and hemangiomas) underwent 3.0 T MRI. Quantitative liver lesion contrast (Q-LLC) and its rate of change (%) at 3, 10, and 15 min postcontrast were analyzed. Tumors were stratified according to albumin–bilirubin (ALBI) grade. For ALBI grade 1, the Q-LLC significantly differed at 3 min and 10 min (P < 0.05). Q-LLC increased over time, and the rate of change was the lowest in HCC, followed by metastases, and was the highest in hemangiomas. Significant differences in the rate of change were observed among tumor types for ALBI grade 1 (P < 0.01). These findings suggest that the Q-LLC rate of change may aid in liver tumor classification, particularly in patients with preserved liver function.
- 18 August 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1294-1301
Effect of posture on renal volume: evaluation using multi-posture MRI
Measurement of renal volume is useful in the early detection and monitoring of renal disease. However, changes in renal volume during postural changes are not clear. Therefore, this study used multi-posture MRI system that can obtain renal images in any posture to assess the effect of posture on renal volume in the supine and upright positions. This study included 11 healthy volunteers (8 men and 3 women; mean age, 23.1 years; body mass index, 19.9 ± 1.3 kg/m2). Multi-posture MRI was used to compare renal volumes (total kidney, renal cortex, renal medulla, and renal pelvis volumes) between supine and upright positions. Wilcoxon signed-rank test was used. A P < 0.05 indicated significance. The total kidney, renal cortex, and renal medulla volumes in the upright position were significantly smaller than those in the supine position (P < 0.05 for all). Multi-posture MRI may provide new information on renal volume.
- 18 August 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1294-1301
Effect of posture on renal volume: evaluation using multi-posture MRI
Measurement of renal volume is useful in the early detection and monitoring of renal disease. However, changes in renal volume during postural changes are not clear. Therefore, this study used multi-posture MRI system that can obtain renal images in any posture to assess the effect of posture on renal volume in the supine and upright positions. This study included 11 healthy volunteers (8 men and 3 women; mean age, 23.1 years; body mass index, 19.9 ± 1.3 kg/m2). Multi-posture MRI was used to compare renal volumes (total kidney, renal cortex, renal medulla, and renal pelvis volumes) between supine and upright positions. Wilcoxon signed-rank test was used. A P < 0.05 indicated significance. The total kidney, renal cortex, and renal medulla volumes in the upright position were significantly smaller than those in the supine position (P < 0.05 for all). Multi-posture MRI may provide new information on renal volume.